hwDot3ahEfmErrSymPeriodWindowHi
HUAWEI-ETHOAM-MIB ·
.1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.1
Object
The two objects hwDot3ahEfmErrSymPeriodWindowHi and
hwDot3ahEfmErrSymPeriodWindowLo together form an unsigned 64-bit
integer representing the number of symbols over which this
threshold event is defined. This is defined as
hwDot3ahEfmErrSymPeriodWindow = ((2^32)*hwDot3ahEfmErrSymPeriodWindowHi)
+ hwDot3ahEfmErrSymPeriodWindowLo
If hwDot3ahEfmErrSymPeriodThreshold symbol errors occur within a
window of hwDot3ahEfmErrSymPeriodWindow symbols, an Event
Notification OAMPDU should be generated with an Errored Symbol
Period Event TLV indicating the threshold has been crossed in
this window.
The default value for hwDot3ahEfmErrSymPeriodWindow is the number
of symbols in one second for the underlying physical layer.
Context
- MIB
- HUAWEI-ETHOAM-MIB
- OID
.1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.1- Type
- column
- Access
- readwrite
- Status
- current
- Units
- 2^32 symbols
- Parent
- hwDot3ahEfmEventConfigEntry
- Table
- hwDot3ahEfmEventConfigTable
- Siblings
- 20
Syntax
2^32 symbols SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hwDot3ahEfmErrFrameThreshold The number of frame errors that must occur for this event to
be triggered. The default value is one frame error. If the
threshold value is zero, then an Event Notification OAMPDU… | column | frames SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.10 |
| hwDot3ahEfmErrFrameEvNotifEnable If true, the OAM entity should send an Event Notification
OAMPDU when an Errored Frame Event occurs.
By default, this object should have the value true for
Ethernet… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.11 |
| hwDot3ahEfmErrFrameSecsSummaryWindow The amount of time (in 100ms intervals) over which the
threshold is defined. The default value is 600 (60 seconds).
If hwDot3ahEfmErrFrameSecsSummaryThreshold fram… | column | tenths of a second Integer32 | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.12 |
| hwDot3ahEfmErrFrameSecsSummaryThreshold The number of errored frame seconds that must occur for this
event to be triggered. The default value is one errored frame
second. If the threshold value is zero, then an Event
N… | column | errored frame seconds Integer32 | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.13 |
| hwDot3ahEfmErrFrameSecsEvNotifEnable If true, the local OAM entity should send an Event
Notification OAMPDU when an Errored Frame Seconds Event
occurs.
By default, this object should have the value tru… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.14 |
| hwDot3ahEfmDyingGaspEnable If true, the local OAM entity should attempt to indicate a
dying gasp via the OAMPDU flags field to its peer OAM entity
when a dying gasp event occurs. The exact definition of a
… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.15 |
| hwDot3ahEfmCriticalEventEnable If true, the local OAM entity should attempt to indicate a
critical event via the OAMPDU flags to its peer OAM entity
when a critical event occurs. The exact definition of a
cri… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.16 |
| hwDot3ahEfmThresholdTriggerErrDown This object indicates whether threshold event will trigger error-shutdown.
If it is enabled(1), after EFM checks that the threshold event happens,
the current interface will be se… | column | P-BRIDGE-MIBEnabledStatus | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.17 |
| hwDot3ahEfmNonThresholdCriticalEventTriggerErrDown This object indicates whether non-threshold critical event will trigger error-shutdown.
If it is enabled(1), after EFM checks that the non-threshold critical event happens,
the cu… | column | P-BRIDGE-MIBEnabledStatus | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.18 |
| hwDot3ahEfmNonThresholdDyinggaspTriggerErrDown This object indicates whether non-threshold dying gasp event will trigger error-shutdown.
If it is enabled(1), after EFM checks that the non-threshold dying gasp event happens,
th… | column | P-BRIDGE-MIBEnabledStatus | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.19 |
| hwDot3ahEfmErrSymPeriodWindowLo The two objects hwDot3ahEfmErrSymPeriodWindowHi and
hwDot3ahEfmErrSymPeriodWindowLo together form an unsigned 64-bit
integer representing the number of symbols over which this
thr… | column | symbols SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.2 |
| hwDot3ahEfmNonThresholdLinkFaultTriggerErrDown This object indicates whether non-threshold link fault event will trigger error-shutdown.
If it is enabled(1), after EFM checks that the non-threshold link fault event happens,
th… | column | P-BRIDGE-MIBEnabledStatus | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.20 |
| hwDot3ahEfmNonThresholdTimeoutTriggerErrDown This object indicates whether non-threshold time out event will trigger error-shutdown.
If it is enabled(1), after EFM checks that the non-threshold time out event happens,
the cu… | column | P-BRIDGE-MIBEnabledStatus | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.21 |
| hwDot3ahEfmErrSymPeriodThresholdHi The two objects hwDot3ahEfmErrSymPeriodThresholdHi and
hwDot3ahEfmErrSymPeriodThresholdLo together form an unsigned
64-bit integer representing the number of symbol errors that
mu… | column | 2^32 symbols SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.3 |
| hwDot3ahEfmErrSymPeriodThresholdLo The two objects hwDot3ahEfmErrSymPeriodThresholdHi and
hwDot3ahEfmErrSymPeriodThresholdLo together form an unsigned
64-bit integer representing the number of symbol errors that
mu… | column | symbols SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.4 |
| hwDot3ahEfmErrSymPeriodEvNotifEnable If true, the OAM entity should send an Event Notification
OAMPDU when an Errored Symbol Period Event occurs.
By default, this object should have the value true for
Ethernet like i… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.5 |
| hwDot3ahEfmErrFramePeriodWindow The number of frames over which the threshold is defined.
The default value of the window is the number of minimum size
Ethernet frames that can be received over the physical laye… | column | frames SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.6 |
| hwDot3ahEfmErrFramePeriodThreshold The number of frame errors that must occur for this event to
be triggered. The default value is one frame error. If the
threshold value is zero, then an Event Notification OAMPD… | column | frames SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.7 |
| hwDot3ahEfmErrFramePeriodEvNotifEnable If true, the OAM entity should send an Event Notification
OAMPDU when an Errored Frame Period Event occurs.
By default, this object should have the value true for
E… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.8 |
| hwDot3ahEfmErrFrameWindow The amount of time (in 100ms increments) over which the
threshold is defined. The default value is 10 (1 second).
If hwDot3ahEfmErrFrameThreshold frame errors occu… | column | tenths of a second SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.9 |