hwDot3ahEfmErrFrameSecsSummaryThreshold

HUAWEI-ETHOAM-MIB · .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.13

Object

column r/w errored frame seconds Integer32
The number of errored frame seconds that must occur for this
event to be triggered.  The default value is one errored frame
second. If the threshold value is zero, then an Event
Notification OAMPDU is sent periodically (at the end of every
window).  This can be used as an asynchronous notification to
the peer OAM entity of the statistics related to this
threshold crossing alarm.
              
If hwDot3ahEfmErrFrameSecsSummaryThreshold frame errors occur
within a window of hwDot3ahEfmErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window.

Context

MIB
HUAWEI-ETHOAM-MIB
OID
.1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.13
Type
column
Access
readwrite
Status
current
Units
errored frame seconds
Parent
hwDot3ahEfmEventConfigEntry
Table
hwDot3ahEfmEventConfigTable
Siblings
20

Syntax

errored frame seconds Integer32

Values & Constraints

Object Constraints
range: 0-900

Related Objects

Sibling Objects