hwDot3ahEfmErrFramePeriodThreshold

HUAWEI-ETHOAM-MIB · .1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.7

Object

column r/w frames SNMPv2-SMIUnsigned32
The number of frame errors that must occur for this event to
be triggered.  The default value is one frame error.  If the
threshold value is zero, then an Event Notification OAMPDU is
sent periodically (at the end of every window).  This can be
used as an asynchronous notification to the peer OAM entity of
the statistics related to this threshold crossing alarm.
              
If hwDot3ahEfmErrFramePeriodThreshold frame errors occur within a
window of hwDot3ahEfmErrFramePeriodWindow frames, an Event
Notification OAMPDU should be generated with an Errored Frame
Period Event TLV indicating the threshold has been crossed in
this window.

Context

MIB
HUAWEI-ETHOAM-MIB
OID
.1.3.6.1.4.1.2011.5.25.136.1.2.2.6.1.7
Type
column
Access
readwrite
Status
current
Units
frames
Parent
hwDot3ahEfmEventConfigEntry
Table
hwDot3ahEfmEventConfigTable
Siblings
20

Syntax

frames SNMPv2-SMIUnsigned32
Source
SNMPv2-SMIUnsigned32
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..4294967295

Related Objects

Sibling Objects