hpSwitchRunningCfgChgTransmitInterval
HP-SWITCH-BASIC-CONFIG-MIB ·
.1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.2
Object
Specifies the transmission interval in seconds for sending running config change traps. Only one running config change trap is sent in this time interval. Default value is 0, indicating there is no limit on sending running config change traps.
Context
- MIB
- HP-SWITCH-BASIC-CONFIG-MIB
- OID
.1.3.6.1.4.1.11.2.14.11.5.1.7.1.29.1.12.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hpSwitchRunningCfgChgObjects
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'HP-SWITCH-BASIC-CONFIG-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'HP-SWITCH-BASIC-CONFIG-MIB::hpSwitchRunningCfgChgTransmitInterval.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'HP-SWITCH-BASIC-CONFIG-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'HP-SWITCH-BASIC-CONFIG-MIB::hpSwitchRunningCfgChgTransmitInterval'
Syntax
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Conformance
Member of