hm2IOModConfigDigOutputSourceAddressType
HM2-IOMODULE-MIB ·
.1.3.6.1.4.1.248.11.100.1.1.3.1.5
Object
Address type of an input mirrored to the output. Currently, only ipv4 is supported.
Context
- MIB
- HM2-IOMODULE-MIB
- OID
.1.3.6.1.4.1.248.11.100.1.1.3.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hm2IOModConfigDigOutputEntry
- Table
- hm2IOModConfigDigOutputTable
- Siblings
- 8
Syntax
INET-ADDRESS-MIBInetAddressType
- Source
- INET-ADDRESS-MIBInetAddressType
- Base type
Enumeration
Values & Constraints
Type Values
0 | unknown |
1 | ipv4 |
2 | ipv6 |
3 | ipv4z |
4 | ipv6z |
16 | dns |
25 | l2vpn |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hm2IOModConfigDigOutputModID The module ID of an output.
Module ID 0 corresponds to the power supply module. | column | Integer32 | .1.3.6.1.4.1.248.11.100.1.1.3.1.1 |
| hm2IOModConfigDigOutputID The ID of an output. | column | Integer32 | .1.3.6.1.4.1.248.11.100.1.1.3.1.2 |
| hm2IOModConfigDigOutputLogEvent Trigger an event log when output status changes.
If the value is disable (2), no event log entry will be written.
If the value is enable (1), an event log entry will be written wh… | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.100.1.1.3.1.3 |
| hm2IOModConfigDigOutputSnmpTrap Trigger an SNMP trap log when output status changes.
If the value is disable (2), no SNMP trap will be sent.
If the value is enable (1), a SNMP trap will be sent when
the output s… | column | HM2-TC-MIBHmEnabledStatus | .1.3.6.1.4.1.248.11.100.1.1.3.1.4 |
| hm2IOModConfigDigOutputSourceAddress The IP address of an input mirrored to the output.
Use 0.0.0.0 if the output should not be set.
In this case hm2IOModValueDigOutputValue is not-configured(4).
Use 127.0.0.1 if a l… | column | INET-ADDRESS-MIBInetAddress | .1.3.6.1.4.1.248.11.100.1.1.3.1.6 |
| hm2IOModConfigDigOutputSourcePort The SNMP port number being used by the input mirrored to the output.
This port would be the destination of the SNMP requests for
polling the state of the input. | column | INET-ADDRESS-MIBInetPortNumber | .1.3.6.1.4.1.248.11.100.1.1.3.1.7 |
| hm2IOModConfigDigOutputSourceModID The module ID of an input mirrored to the output.
Module ID 0 corresponds to the power supply module.
Ignored when hm2IOModConfigDigOutputSourceIP is 0.0.0.0. | column | Integer32 | .1.3.6.1.4.1.248.11.100.1.1.3.1.8 |
| hm2IOModConfigDigOutputSourceID The ID of an input mirrored to the output.
Ignored when hm2IOModConfigDigOutputSourceIP is 0.0.0.0. | column | Integer32 | .1.3.6.1.4.1.248.11.100.1.1.3.1.9 |