hh3cVoiceIfCfgEchoCancelSwitch
HH3C-VOICE-IF-MIB ·
.1.3.6.1.4.1.25506.2.39.13.1.1.1.5
Object
column
r/w
Enumeration
This object indicates whether the echo cancellation is enabled. It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice subscriber line.
Context
- MIB
- HH3C-VOICE-IF-MIB
- OID
.1.3.6.1.4.1.25506.2.39.13.1.1.1.5- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- hh3cVoiceIfConfigEntry
- Table
- hh3cVoiceIfConfigTable
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | enable |
2 | disable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| hh3cVoiceIfCfgCngOn This object indicates whether the silence gaps should be
filled with background noise. It is applicable to FXO, FXS,
E&M subscriber lines and E1/T1 voice subscriber line. | column | Enumeration | .1.3.6.1.4.1.25506.2.39.13.1.1.1.1 |
| hh3cVoiceIfCfgRegTone This object uses 2 or 3 letter country code specify voice
parameters of different countrys. This value will take effect
on all voice interfaces of all cards on the device. | column | OctetString | .1.3.6.1.4.1.25506.2.39.13.1.1.1.10 |
| hh3cVoiceIfCfgNonLinearSwitch This object expresses the nonlinear processing is enable
or disable for the voice interface. It is applicable to FXO,
FXS, E&M subscriber lines and E1/T1 voice subscriber line.
Cu… | column | Enumeration | .1.3.6.1.4.1.25506.2.39.13.1.1.1.2 |
| hh3cVoiceIfCfgInputGain This object indicates the amount of gain added to the receiver
side of the voice interface. Unit is 0.1 db. It is applicable to
FXO, FXS, E&M subscriber lines and E1/T1 voice subs… | column | Integer32 | .1.3.6.1.4.1.25506.2.39.13.1.1.1.3 |
| hh3cVoiceIfCfgOutputGain This object indicates the amount of gain added to the send side
of the voice interface. Unit is 0.1 db. It is applicable to FXO,
FXS, E&M subscriber lines and E1/T1 voice subscrib… | column | Integer32 | .1.3.6.1.4.1.25506.2.39.13.1.1.1.4 |
| hh3cVoiceIfCfgEchoCancelDelay This object indicates the delay of the echo cancellation for
the voice interface. This value couldn't be modified unless
hh3cVoiceIfCfgEchoCancelSwitch is enable. Unit is millisec… | column | Integer32 | .1.3.6.1.4.1.25506.2.39.13.1.1.1.6 |
| hh3cVoiceIfCfgTimerDialInterval The interval, in seconds, between two dialing numbers.
The default value of this object is 10 seconds. It is
applicable to FXO, FXS, E&M subscriber lines and E1/T1 with
loop-start… | column | Integer32 | .1.3.6.1.4.1.25506.2.39.13.1.1.1.7 |
| hh3cVoiceIfCfgTimerFirstDial The period of time, in seconds, before dialing the first
number. The default value of this object is 10 seconds. It
is applicable to FXO, FXS subscriber lines and E1/T1 with
loop-… | column | Integer32 | .1.3.6.1.4.1.25506.2.39.13.1.1.1.8 |
| hh3cVoiceIfCfgPrivateline This object indicates the E.164 phone number for plar mode.
It is applicable to FXO, FXS, E&M subscriber lines and E1/T1
voice subscriber line. | column | OctetString | .1.3.6.1.4.1.25506.2.39.13.1.1.1.9 |