HH3C-VOICE-IF-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
1
Rows
1
Columns
10
.1.3.6.1.4.1.25506.2.39.13.1.1 · 1 row entry · 10 columns
The table contains configurable parameters for both analog
voice interface and digital voice interface.
hh3cVoiceIfConfigEntry entry .1.3.6.1.4.1.25506.2.39.13.1.1.1
The entry of voice interface table.
Indexes
IF-MIBifIndex
Column Syntax OID
hh3cVoiceIfCfgCngOn
This object indicates whether the silence gaps should be
filled with background noise. It is applicable to FXO, FXS,
E&M subscriber lines and E1/T1 voice subscriber line.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.25506.2.39.13.1.1.1.1
hh3cVoiceIfCfgNonLinearSwitch
This object expresses the nonlinear processing is enable
or disable for the voice interface. It is applicable to FXO,
FXS, E&M subscriber lines and E1/T1 voice subscriber line.
Currently, only digital voice subscriber l…
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.25506.2.39.13.1.1.1.2
hh3cVoiceIfCfgInputGain
This object indicates the amount of gain added to the receiver
side of the voice interface. Unit is 0.1 db. It is applicable to
FXO, FXS, E&M subscriber lines and E1/T1 voice subscriber line.
Integer32r/w
Constraints:
range: -140-139
.1.3.6.1.4.1.25506.2.39.13.1.1.1.3
hh3cVoiceIfCfgOutputGain
This object indicates the amount of gain added to the send side
of the voice interface. Unit is 0.1 db. It is applicable to FXO,
FXS, E&M subscriber lines and E1/T1 voice subscriber line.
Integer32r/w
Constraints:
range: -140-139
.1.3.6.1.4.1.25506.2.39.13.1.1.1.4
hh3cVoiceIfCfgEchoCancelSwitch
This object indicates whether the echo cancellation is enabled.
It is applicable to FXO, FXS, E&M subscriber lines and E1/T1 voice
subscriber line.
Enumerationr/w
Enumerated Values:
1enable
2disable
.1.3.6.1.4.1.25506.2.39.13.1.1.1.5
hh3cVoiceIfCfgEchoCancelDelay
This object indicates the delay of the echo cancellation for
the voice interface. This value couldn't be modified unless
hh3cVoiceIfCfgEchoCancelSwitch is enable. Unit is milliseconds.
It is applicable to FXO, FXS, E&M …
Integer32r/w
Constraints:
range: 0-64
.1.3.6.1.4.1.25506.2.39.13.1.1.1.6
hh3cVoiceIfCfgTimerDialInterval
The interval, in seconds, between two dialing numbers.
The default value of this object is 10 seconds. It is
applicable to FXO, FXS, E&M subscriber lines and E1/T1 with
loop-start or ground-start protocol voice subscrib…
Integer32r/w
Constraints:
range: 1-300
.1.3.6.1.4.1.25506.2.39.13.1.1.1.7
hh3cVoiceIfCfgTimerFirstDial
The period of time, in seconds, before dialing the first
number. The default value of this object is 10 seconds. It
is applicable to FXO, FXS subscriber lines and E1/T1 with
loop-start or ground-start protocol voice sub…
Integer32r/w
Constraints:
range: 1-300
.1.3.6.1.4.1.25506.2.39.13.1.1.1.8
hh3cVoiceIfCfgPrivateline
This object indicates the E.164 phone number for plar mode.
It is applicable to FXO, FXS, E&M subscriber lines and E1/T1
voice subscriber line.
OctetStringr/w
Constraints:
range: 0-31
.1.3.6.1.4.1.25506.2.39.13.1.1.1.9
hh3cVoiceIfCfgRegTone
This object uses 2 or 3 letter country code specify voice
parameters of different countrys. This value will take effect
on all voice interfaces of all cards on the device.
OctetStringr/w
Constraints:
range: 0-0
range: 2-3
.1.3.6.1.4.1.25506.2.39.13.1.1.1.10