hh3cPOEThresholdACMimimum
HH3C-POWER-ETH-EXT-MIB ·
.1.3.6.1.4.1.25506.2.14.8.1.1
Object
scalar
r/w
OctetString
Input threshold AC minimum. It is a read-write node. The value of this node is 'OCTET STRING', it is used to describe a float value. So this string should fit the following rule: 1. This string should be terminated by '\0'; 2. Every characters should be number or radix point; 3. The radix point should occur only once, and it should not be the first or the last character of the string. The value of this node should be smaller than 264.0V and larger than 90.0V. And it should be smaller than the hh3cPOEThresholdACMaximum.
Context
- MIB
- HH3C-POWER-ETH-EXT-MIB
- OID
.1.3.6.1.4.1.25506.2.14.8.1.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- hh3cPOEThresholdLimitObjs
Syntax
OctetString
Values & Constraints
Object Constraints
range: 1-10