cmgPowerMgProcessor

G700-MG-MIB · .1.3.6.1.4.1.6889.2.9.1.1.10.7

Object

Voltage reading in millivolts at the power supply serving the Media
Gateway main processor.  Nominal value is +5100 mV.  If the reading
falls outside the range 4950 to 5250 mV, a trap is sent to the
management console and the corresponding bit in the fault mask
is turned on.

Context

MIB
G700-MG-MIB
OID
.1.3.6.1.4.1.6889.2.9.1.1.10.7
Type
scalar
Access
readonly
Status
current
Parent
cmgHardware

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'G700-MG-MIB' -M '/opt/observium/mibs/avaya:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'G700-MG-MIB::cmgPowerMgProcessor.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'G700-MG-MIB' -M '/opt/observium/mibs/avaya:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'G700-MG-MIB::cmgPowerMgProcessor'

Syntax

Source
SNMPv2-SMIInteger32
Base type
Integer32

Values & Constraints

Type Constraints
range: -2147483648..2147483647