netNodeObjects
FORCEPOINT-NGFW-ENGINE-MIB ·
.1.3.6.1.4.1.47565.1.1.1.19
Object
node
No description available.
Context
- MIB
- FORCEPOINT-NGFW-ENGINE-MIB
- OID
.1.3.6.1.4.1.47565.1.1.1.19- Type
- node
- Parent
- engineObjects
- Siblings
- 21
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| fwSoftwareVersion Version string of the firewall software | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.47565.1.1.1.1 |
| fwIfStatsTable This table contains an entry for each
interface in system | table | - | .1.3.6.1.4.1.47565.1.1.1.10 |
| fwHardware | node | - | .1.3.6.1.4.1.47565.1.1.1.11 |
| fwVpnEp4Table This table contains an entry for each
IPv4 VPN end-point pair | table | - | .1.3.6.1.4.1.47565.1.1.1.12 |
| fwVpnEp6Table This table contains an entry for each
IPv6 VPN end-point pair | table | - | .1.3.6.1.4.1.47565.1.1.1.13 |
| fwMbrInterfaceTable This table contains an entry for each cellular
interface in system | table | - | .1.3.6.1.4.1.47565.1.1.1.14 |
| fwDiskSerialNumber Disk serial number | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.47565.1.1.1.15 |
| fwHwTempSensorTable This table contains an entry for each
temperature sensor in system | table | - | .1.3.6.1.4.1.47565.1.1.1.16 |
| fwPsuTable This table contains an entry for each
power supply unit in system | table | - | .1.3.6.1.4.1.47565.1.1.1.17 |
| fwFanTable This table contains an entry for each
fan in system | table | - | .1.3.6.1.4.1.47565.1.1.1.18 |
| fwSecurityPolicy Name of the current security policy on the
firewall | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.47565.1.1.1.2 |
| fwVoltageTable This table contains an entry for each
voltage in system | table | - | .1.3.6.1.4.1.47565.1.1.1.20 |
| fwVETable This table contains an entry for each
virtual engine | table | - | .1.3.6.1.4.1.47565.1.1.1.21 |
| fwIfStatsProcTable This table contains an entry for each
interface in system | table | - | .1.3.6.1.4.1.47565.1.1.1.22 |
| fwPolicyTime The time when the security policy was
installed to the firewall | scalar | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.47565.1.1.1.3 |
| fwConnNumber Number of current connections | scalar | HCNUM-TCCounterBasedGauge64 | .1.3.6.1.4.1.47565.1.1.1.4 |
| fwAccepted Number of accepted packets | scalar | SNMPv2-SMICounter64 | .1.3.6.1.4.1.47565.1.1.1.5 |
| fwDropped Number of dropped packets | scalar | SNMPv2-SMICounter64 | .1.3.6.1.4.1.47565.1.1.1.6 |
| fwLogged Number of logged packets | scalar | SNMPv2-SMICounter64 | .1.3.6.1.4.1.47565.1.1.1.7 |
| fwAccounted Number of accounted packets | scalar | SNMPv2-SMICounter64 | .1.3.6.1.4.1.47565.1.1.1.8 |
| fwRejected Number of rejected packets | scalar | SNMPv2-SMICounter64 | .1.3.6.1.4.1.47565.1.1.1.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| nodeClusterId The identification number of the cluster
this node belongs to | scalar | Integer32 | .1.3.6.1.4.1.47565.1.1.1.19.1 |
| nodePosCode Appliance POS code | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.47565.1.1.1.19.10 |
| nodeLoginTime The most recent login event on the node | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.47565.1.1.1.19.11 |
| nodePolicyApplyTime The time when the security policy was installed to the node | scalar | SNMPv2-TCDateAndTime | .1.3.6.1.4.1.47565.1.1.1.19.12 |
| nodeHardwareSerialNumber Hardware chassis serial number | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.47565.1.1.1.19.13 |
| nodeMemberId Node's member identification within the cluster | scalar | Integer32 | .1.3.6.1.4.1.47565.1.1.1.19.2 |
| nodeOperState The operative (clustering) state of the node | scalar | Enumeration | .1.3.6.1.4.1.47565.1.1.1.19.3 |
| nodeCPULoad The CPU load percentage on the node | scalar | Integer32 | .1.3.6.1.4.1.47565.1.1.1.19.4 |
| nodeLastLogin The most recent login event on the node | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.47565.1.1.1.19.5 |
| nodeLastLoginTime Timestamp of the most recent login event on the node | scalar | SNMPv2-TCTimeStamp | .1.3.6.1.4.1.47565.1.1.1.19.6 |
| nodeTestTable This table contains an entry for each
test instance that was
configured to send a trap on test failure | table | - | .1.3.6.1.4.1.47565.1.1.1.19.7 |
| nodeHwmonEvent Reason for the hardware monitoring event | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.47565.1.1.1.19.8 |
| nodeApplianceModel Appliance model name | scalar | SNMPv2-TCDisplayString | .1.3.6.1.4.1.47565.1.1.1.19.9 |