flowManagerCurrentRuleSet
FLOW-METER-MIB ·
.1.3.6.1.2.1.40.1.4.1.2
Object
Index to the array of RuleSets. Specifies which set of
rules is the 'current' one for this task. The meter will
be 'running' the current RuleSet if this row's
flowManagerRunningStandby value is false(2).
When the manager sets this variable the meter will stop using
the task's old current RuleSet and start using the new one.
Specifying RuleSet 0 (the empty set) stops flow measurement
for this task.
Context
- MIB
- FLOW-METER-MIB
- OID
.1.3.6.1.2.1.40.1.4.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- flowManagerInfoEntry
- Groups
- 2
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'FLOW-METER-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FLOW-METER-MIB::flowManagerCurrentRuleSet'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'FLOW-METER-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'FLOW-METER-MIB::flowManagerCurrentRuleSet.<flowManagerIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'FLOW-METER-MIB' -M '/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'FLOW-METER-MIB::flowManagerCurrentRuleSet'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Conformance
Member of