flowManagerInfoEntry
FLOW-METER-MIB ·
.1.3.6.1.2.1.40.1.4.1
Object
row
Information about a particular meter 'task.' By creating
an entry in this table and activating it, a manager requests
that the meter 'run' the indicated RuleSet.
The entry also specifies a HighWaterMark and a StandbyRuleSet.
If the meter's flow table usage exceeds this task's
HighWaterMark the meter will stop running the task's
CurrentRuleSet and switch to its StandbyRuleSet.
If the value of the task's StandbyRuleSet is 0 when its
HighWaterMark is exceeded, the meter simply stops running the
task's CurrentRuleSet. By careful selection of HighWaterMarks
for the various tasks a manager can ensure that the most
critical RuleSets are the last to stop running as the number
of flows increases.
When a manager has determined that the demand for flow table
space has abated, it may cause the task to switch back to its
CurrentRuleSet by setting its flowManagerRunningStandby
variable to false(2).
Context
- MIB
- FLOW-METER-MIB
- OID
.1.3.6.1.2.1.40.1.4.1- Type
- row
- Status
- current
- Parent
- flowManagerInfoTable
- Table
- flowManagerInfoTable
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints