cableDiagResultStatusPairB
ES3552M-AND-PoE-MIB ·
.1.3.6.1.4.1.259.8.1.12.1.2.3.2.1.3
Object
column
Enumeration
The result of cable diagnostics. If there is no fault on the cable, the value is ok(2). Value notTestedYet(1) means the pair is not tested yet. Value ok(2) means the pair works well. Value open(3) means there is a lack of continuity between pins at each end of the pair. Value short(4) means conductors are short-circuited together on the pair. Value openShort(5) means the pair has open and short issues. Value crosstalk(6) means the pair is incorrectly connected at one end. Value unknown(7) means pair has an error matching none of the above. Value impedanceMismatch(8) means different quality cables connected together. Value fail(9) means test failed. Value notSupport(10) means cable diagnostics is not supported.
Context
- MIB
- ES3552M-AND-PoE-MIB
- OID
.1.3.6.1.4.1.259.8.1.12.1.2.3.2.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cableDiagResultEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | notTestedYet |
2 | ok |
3 | open |
4 | short |
5 | openShort |
6 | crosstalk |
7 | unknown |
8 | impedanceMismatch |
9 | fail |
10 | notSupport |