eltexVpcDomainSystemPriority
ELTEX-VPC-MIB ·
.1.3.6.1.4.1.35265.125.1.1.2.1.7
Object
column
r/w
Unsigned32
To configure the system priority for the VPC domain. This is used in the STP BPDU sent out on VPC member ports. System-priority should be configured same on both the VPC peers. If the configured VPC system priority is different on VPC peers, then VPC will not come up.
Context
- MIB
- ELTEX-VPC-MIB
- OID
.1.3.6.1.4.1.35265.125.1.1.2.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- eltexVpcDomainConfigEntry
- Table
- eltexVpcDomainConfigTable
- Siblings
- 13
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-65535
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eltexVpcDomainIndex VPC Domain ID. | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.1 |
| eltexVpcDomainPeerDetectionTimeout To configure the peer detection protocol reception timeout.
Configurable range is 700 to 14000 mseconds. | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.10 |
| eltexVpcDomainPeerIpAddr To configure IP address of the peer VPC switch. This
configuration is used by the dual control plane detection
protocol on the VPC switches.
NOTE: In order to set v… | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.35265.125.1.1.2.1.11 |
| eltexVpcDomainSourceIpAddr To configure Self IP address of the VPC switch that is used as
the source IP by the dual control plane detection protocol
on the VPC switches.
NOTE: In order to se… | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.35265.125.1.1.2.1.12 |
| eltexVpcDomainDcpdpUdpPort To configure the UDP port on which the VPC switch listens to
the peer detection protocol messages. | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.13 |
| eltexVpcDomainStatus Status of VPC Domain. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.35265.125.1.1.2.1.14 |
| eltexVpcDomainPeerLink To configures a port channel as the VPC peer link.
The configurable range is a valid port channel interface index. | column | IF-MIBInterfaceIndexOrZero | .1.3.6.1.4.1.35265.125.1.1.2.1.2 |
| eltexVpcDomainKeepalivePriority To configure the priority of the VPC switch. This value is used
for the VPC role election.
Note: The VPC switch with lower priority becomes the Primary. If
both the VPC peer… | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.3 |
| eltexVpcDomainKeepaliveTimeout To configure the peer keepalive timeout value (in seconds). If
an VPC switch does not receive keepalive messages from the peer
for this timeout value, it takes the decision to tra… | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.4 |
| eltexVpcDomainKeepaliveMode To start/stop the keepalive state machine on the VPC device, if
VPC is globally enabled. | column | Enumeration | .1.3.6.1.4.1.35265.125.1.1.2.1.5 |
| eltexVpcDomainSystemMac To configure the MAC address for the VPC domain. This mac-address
is used in the LACP PDUs and STP BPDUs
that are sent out on VPC member ports. For the VPC domain to use
the ma… | column | SNMPv2-TCMacAddress | .1.3.6.1.4.1.35265.125.1.1.2.1.6 |
| eltexVpcDomainPeerDetectionMode To start/stop the dual control peer detection protocol on the
VPC switch.
The following options are supported:
Note: The peer VPC switch's IP address has to be conf… | column | Enumeration | .1.3.6.1.4.1.35265.125.1.1.2.1.8 |
| eltexVpcDomainPeerDetectionInterval To configure the peer detection protocol transmission interval.
Configurable range is 200 to 4000 mseconds. | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.9 |