eltexVpcDomainSystemMac
ELTEX-VPC-MIB ·
.1.3.6.1.4.1.35265.125.1.1.2.1.6
Object
To configure the MAC address for the VPC domain. This mac-address is used in the LACP PDUs and STP BPDUs that are sent out on VPC member ports. For the VPC domain to use the manually configured VPC MAC address, it should be manually configured on both the VPC peers and should be the same. If VPC is configured on only one of the VPC peers or is configured different on VPC peers, auto-generated MAC address is used. The specified MAC address should be a unicast MAC address in <aa:bb:cc:dd:ee:ff> format and should not be equal to the MAC address of either primary VPC or secondary VPC device. The manually configured VPC MAC address is used instead of auto-generated VPC MAC address only if the VPC feature is re-enabled after configuring the VPC MAC address.
Context
- MIB
- ELTEX-VPC-MIB
- OID
.1.3.6.1.4.1.35265.125.1.1.2.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- eltexVpcDomainConfigEntry
- Table
- eltexVpcDomainConfigTable
- Siblings
- 13
Values & Constraints
Type Constraints
range: 6
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| eltexVpcDomainIndex VPC Domain ID. | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.1 |
| eltexVpcDomainPeerDetectionTimeout To configure the peer detection protocol reception timeout.
Configurable range is 700 to 14000 mseconds. | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.10 |
| eltexVpcDomainPeerIpAddr To configure IP address of the peer VPC switch. This
configuration is used by the dual control plane detection
protocol on the VPC switches.
NOTE: In order to set v… | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.35265.125.1.1.2.1.11 |
| eltexVpcDomainSourceIpAddr To configure Self IP address of the VPC switch that is used as
the source IP by the dual control plane detection protocol
on the VPC switches.
NOTE: In order to se… | column | SNMPv2-SMIIpAddress | .1.3.6.1.4.1.35265.125.1.1.2.1.12 |
| eltexVpcDomainDcpdpUdpPort To configure the UDP port on which the VPC switch listens to
the peer detection protocol messages. | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.13 |
| eltexVpcDomainStatus Status of VPC Domain. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.35265.125.1.1.2.1.14 |
| eltexVpcDomainPeerLink To configures a port channel as the VPC peer link.
The configurable range is a valid port channel interface index. | column | IF-MIBInterfaceIndexOrZero | .1.3.6.1.4.1.35265.125.1.1.2.1.2 |
| eltexVpcDomainKeepalivePriority To configure the priority of the VPC switch. This value is used
for the VPC role election.
Note: The VPC switch with lower priority becomes the Primary. If
both the VPC peer… | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.3 |
| eltexVpcDomainKeepaliveTimeout To configure the peer keepalive timeout value (in seconds). If
an VPC switch does not receive keepalive messages from the peer
for this timeout value, it takes the decision to tra… | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.4 |
| eltexVpcDomainKeepaliveMode To start/stop the keepalive state machine on the VPC device, if
VPC is globally enabled. | column | Enumeration | .1.3.6.1.4.1.35265.125.1.1.2.1.5 |
| eltexVpcDomainSystemPriority To configure the system priority for the VPC domain. This is used
in the STP BPDU sent out on VPC member ports. System-priority
should be configured same on both the VPC peers. … | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.7 |
| eltexVpcDomainPeerDetectionMode To start/stop the dual control peer detection protocol on the
VPC switch.
The following options are supported:
Note: The peer VPC switch's IP address has to be conf… | column | Enumeration | .1.3.6.1.4.1.35265.125.1.1.2.1.8 |
| eltexVpcDomainPeerDetectionInterval To configure the peer detection protocol transmission interval.
Configurable range is 200 to 4000 mseconds. | column | Unsigned32 | .1.3.6.1.4.1.35265.125.1.1.2.1.9 |