dvmNumberDCPowerSupply

ELECTROLINE-DVM-STATUS-MIB · .1.3.6.1.4.1.5802.1.3.1.3.3.10

Object

scalar Integer32
Number of entries in the internal DC power supply table
A zero entry means the table does not exist and the functional
area is not present in the device.

Context

MIB
ELECTROLINE-DVM-STATUS-MIB
OID
.1.3.6.1.4.1.5802.1.3.1.3.3.10
Type
scalar
Access
readonly
Status
current

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'ELECTROLINE-DVM-STATUS-MIB' -M '/opt/observium/mibs/electroline:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'ELECTROLINE-DVM-STATUS-MIB::dvmNumberDCPowerSupply.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'ELECTROLINE-DVM-STATUS-MIB' -M '/opt/observium/mibs/electroline:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'ELECTROLINE-DVM-STATUS-MIB::dvmNumberDCPowerSupply'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 0-16