pmo10010MesrlineMsaTemp

EKINOPS-Pmo10010-MIB · .1.3.6.1.4.1.20044.76.3.3.12

Object

scalar Unsigned32
Line Trscv Temperature :This OID 
gives the temperature value of
 the Line Transceiver, read from 
the DDM (Digital Diagnostic Monitoring) 
 (Temperature = AV/256) (Unit = 
C) <Help> This Measure gives the 
temperature value of the Line Transceiver.This 
temperature must remain below 95?C 
for proper operation

Context

MIB
EKINOPS-Pmo10010-MIB
OID
.1.3.6.1.4.1.20044.76.3.3.12
Type
scalar
Access
readonly
Status
current
Parent
pmo10010MesrLine

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EKINOPS-Pmo10010-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pmo10010-MIB::pmo10010MesrlineMsaTemp.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EKINOPS-Pmo10010-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EKINOPS-Pmo10010-MIB::pmo10010MesrlineMsaTemp'

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-65535