pm200frs02MesrregTemp

OBS ✓
EKINOPS-Pm200frs02-MIB · .1.3.6.1.4.1.20044.90.3.1.251

Object

scalar Unsigned32
Regulator Temperature :This OID 
gives the temperature value of
 the Regulator (Temperature = AV_S16) 
(Unit = C) <Help> This Measure
 gives the Regulator Temperature
Observium directly uses this object
This object is referenced by an Observium discovery or polling workflow.
Used in: Sensors
Explore Observium network monitoring

Context

MIB
EKINOPS-Pm200frs02-MIB
OID
.1.3.6.1.4.1.20044.90.3.1.251
Type
scalar
Access
readonly
Status
current
Parent
pm200frs02MesrOther

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EKINOPS-Pm200frs02-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm200frs02-MIB::pm200frs02MesrregTemp.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EKINOPS-Pm200frs02-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EKINOPS-Pm200frs02-MIB::pm200frs02MesrregTemp'

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-65535