pm200fr20MesrlineTrscvVoltage

EKINOPS-Pm200fr20-MIB · .1.3.6.1.4.1.20044.87.3.1.408

Object

scalar Unsigned32
Line Trscv Voltage :This OID gives 
the voltage value of the QSFP plugged 
into the port, read from the DDM 
(Digital Diagnostic Monitoring) 
(Voltage = AV_U16/10000) (Unit
 = V)  <Help>  This measure gives 
the power supply voltage of the 
transceiver

Context

MIB
EKINOPS-Pm200fr20-MIB
OID
.1.3.6.1.4.1.20044.87.3.1.408
Type
scalar
Access
readonly
Status
current
Parent
pm200fr20MesrOther

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'EKINOPS-Pm200fr20-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'EKINOPS-Pm200fr20-MIB::pm200fr20MesrlineTrscvVoltage.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'EKINOPS-Pm200fr20-MIB' -M '/opt/observium/mibs/ekinops:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'EKINOPS-Pm200fr20-MIB::pm200fr20MesrlineTrscvVoltage'

Syntax

Unsigned32

Values & Constraints

Object Constraints
range: 0-65535