unitUtilitiesFarIndex
DS8200v2-MIB ·
.1.3.6.1.4.1.321.100.2.12.1.1.2
Object
column
Integer32
Selects the far device.
Context
- MIB
- DS8200v2-MIB
- OID
.1.3.6.1.4.1.321.100.2.12.1.1.2- Type
- column
- Access
- readonly
- Status
- current
- Parent
- unitUtilitiesTableEntry
- Table
- unitUtilitiesTable
- Siblings
- 13
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| unitUtilitiesNearIndex Selects the near device. | column | Integer32 | .1.3.6.1.4.1.321.100.2.12.1.1.1 |
| unitUtilitiesRestartStatus This parameter indicates if the unit configuration needs to be saved and restarted.
notNeeded - A save and restart is not needed at this time.
recommended - A save and restart is … | column | Enumeration | .1.3.6.1.4.1.321.100.2.12.1.1.10 |
| unitUtilitiesReadOnlyPassword The password for read only access to a device (VT100, front panel). | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.321.100.2.12.1.1.11 |
| unitUtilitiesPasswordLockoutEnable This parameter is used to enable or disable the password lockout feature. | column | Enumeration | .1.3.6.1.4.1.321.100.2.12.1.1.12 |
| unitUtilitiesPasswordLockoutStatus This parameter indicates if the password lockout feature is enabled
or disabled, and if it is enabled this parameter may reflect if the
password is indeed locked. | column | Enumeration | .1.3.6.1.4.1.321.100.2.12.1.1.13 |
| unitUtilitiesPasswordLockoutClear This parameter is used to unlock a locked password. | column | Enumeration | .1.3.6.1.4.1.321.100.2.12.1.1.14 |
| unitUtilitiesLocalPassword The password for local access to a device (VT100, front panel). | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.321.100.2.12.1.1.3 |
| unitUtilitiesTime This string is the current time as known to the device. The current time may be entered in this field using the HHMMSS format. For example, 3:45AM is entered as 034500 and 3:45P… | column | OctetString | .1.3.6.1.4.1.321.100.2.12.1.1.4 |
| unitUtilitiesDate This string is the current date as known to the device. The current date may be entered in this field using the MMDDYY format. For example, July 4, 1997 is entered as 070497. | column | OctetString | .1.3.6.1.4.1.321.100.2.12.1.1.5 |
| unitUtilitiesMaintenanceReset This field allows resetting the device to default values by reloading the start-up default configuration parameters. | column | Enumeration | .1.3.6.1.4.1.321.100.2.12.1.1.6 |
| unitUtilitiesAlarmResetTimer This field allows setting a timer which will cause all existing alarms on the device to be cleared upon expiration. The counter is in seconds. | column | Integer32 | .1.3.6.1.4.1.321.100.2.12.1.1.7 |
| unitUtilitiesAlarmClear Writing a value of utilitiesAlarmClearNow(2) to this field causes all existing alarms to be cleared immediately. | column | Enumeration | .1.3.6.1.4.1.321.100.2.12.1.1.8 |
| unitUtilitiesSaveConfig This field commands the unit to save its configuration. | column | Enumeration | .1.3.6.1.4.1.321.100.2.12.1.1.9 |