docsDiagLogRangingRetryStationMaintNum
DOCS-DIAG-MIB ·
.1.3.6.1.4.1.4491.2.1.9.1.2.7
Object
scalar
r/w
Unsigned32
Number of station maintenance opportunities to monitor for ranging retry trigger. This value implies time intervals in a certain range. DOCSIS requires the CMTS to schedule ranging opportunity to Cable Modem sufficiently smaller than T4. There is no fixed formula to derive at a fixed time interval, how many ranging opportunities would be offered to a Cable Modem by the CMTS, hence using the number of station maintenance opportunities provides ratio with the fixed denominators while also taking time factor into consideration.
Context
- MIB
- DOCS-DIAG-MIB
- OID
.1.3.6.1.4.1.4491.2.1.9.1.2.7- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- docsDiagLogTriggersCfg
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 60-65535