agentG8032ProfileHoldOffTimer

DNOS-G8032-PRIVATE-MIB · .1.3.6.1.4.1.674.10895.5000.2.6132.1.1.72.1.1.1.4

Object

column r/w milliseconds Unsigned32
When a new defect or more severe defect occurs, this event will
not be reported immediately to protection switching if the provisioned
hold-off timer value is non-zero. Instead, the hold-off timer will be started.
When the hold-off timer expires, it will be checked whether a defect still
exists on the trail that started the timer. If it does, that defect will be
reported to protection switching. Specify holdoff timer value in steps of 100ms.

Context

MIB
DNOS-G8032-PRIVATE-MIB
OID
.1.3.6.1.4.1.674.10895.5000.2.6132.1.1.72.1.1.1.4
Type
column
Access
readwrite
Status
current
Units
milliseconds
Parent
agentG8032ProfileEntry
Table
agentG8032ProfileTable
Siblings
5

Syntax

milliseconds Unsigned32

Values & Constraints

Object Constraints
range: 0-10000