rmonAlarmVariable
DES-1210-28ME-B2 ·
.1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.3
Object
column
r/w
ObjectIdentifier
The object identifier of the particular variable to be
sampled. Only variables that resolve to an ASN.1 primitive
type of INTEGER (INTEGER, Integer32, Counter32, Counter64,
Gauge, or TimeTicks) may be sampled.
Because SNMP access control is articulated entirely
in terms of the contents of MIB views, no access
control mechanism exists that can restrict the value of
this object to identify only those objects that exist
in a particular MIB view. Because there is thus no
acceptable means of restricting the read access that
could be obtained through the alarm mechanism, the
probe must only grant write access to this object in
those views that have read access to all objects on
the probe.
During a set operation, if the supplied variable name is
not available in the selected MIB view, a badValue error
must be returned. If at any time the variable name of
an established alarmEntry is no longer available in the
selected MIB view, the probe must change the status of
this alarmEntry to invalid(4).
This object may not be modified if the associated
alarmStatus object is equal to valid(1).
Context
- MIB
- DES-1210-28ME-B2
- OID
.1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- rmonAlarmEntry
- Table
- rmonAlarmTable
- Siblings
- 9
Syntax
ObjectIdentifier
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| rmonAlarmIndex An index that uniquely identifies an entry in the
alarm table. Each such entry defines a
diagnostic sample at a particular interval
for an object on the device. | column | Integer32 | .1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.1 |
| rmonAlarmStatus The status of this alarm entry. | column | RmonStatus | .1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.10 |
| rmonAlarmInterval The interval in seconds over which the data is
sampled and compared with the rising and falling
thresholds. When setting this variable, care
should be taken in the case of deltaV… | column | Seconds SNMPv2-SMIInteger32 | .1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.2 |
| rmonAlarmSampleType The method of sampling the selected variable and
calculating the value to be compared against the
thresholds. If the value of this object is
absoluteValue(1), the value of the se… | column | Enumeration | .1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.4 |
| rmonAlarmRisingThreshold A threshold for the sampled statistic. When the current
sampled value is greater than or equal to this threshold,
and the value at the last sampling interval was less than
this t… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.5 |
| rmonAlarmFallingThreshold A threshold for the sampled statistic. When the current
sampled value is less than or equal to this threshold,
and the value at the last sampling interval was greater than
this t… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.6 |
| rmonAlarmRisingEventIndex The index of the eventEntry that is
used when a rising threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same v… | column | Integer32 | .1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.7 |
| rmonAlarmFallingEventIndex The index of the eventEntry that is
used when a falling threshold is crossed. The
eventEntry identified by a particular value of
this index is the same as identified by the same … | column | Integer32 | .1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.8 |
| rmonAlarmOwner The entity that configured this entry and is therefore
using the resources assigned to it. | column | OwnerString | .1.3.6.1.4.1.171.10.75.15.2.22.4.1.1.9 |