dcLmpProductHelloDeadIvlDfltMin
DC-LMP-PROD ·
.1.3.6.1.4.1.629.10.5.1.1.1.12
Object
column r/w
millisecondsUnsigned32
This object specifies the default minimum value for the
HelloDeadInterval parameter. It is used as a default value
for lmpCcHelloDeadIntervalMin.
This field can be set to zero to disable the LMP Hello
mechanism.
Context
- MIB
- DC-LMP-PROD
- OID
.1.3.6.1.4.1.629.10.5.1.1.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- dcLmpProductEntry
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'DC-LMP-PROD' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DC-LMP-PROD::dcLmpProductHelloDeadIvlDfltMin'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'DC-LMP-PROD' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'DC-LMP-PROD::dcLmpProductHelloDeadIvlDfltMin.<index>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'DC-LMP-PROD' -M '/opt/observium/mibs/mrv:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'DC-LMP-PROD::dcLmpProductHelloDeadIvlDfltMin'
Syntax
millisecondsUnsigned32
Values & Constraints
No enumerated values or constraints recorded.
Conformance
Member of