dcLmpProductHelloDeadIvlDflt
DC-LMP-PROD ·
.1.3.6.1.4.1.629.10.5.1.1.1.11
Object
column
r/w
milliseconds Unsigned32
This object specifies the default HelloDeadInterval parameter to
use in the Hello protocol keep-alive phase. It indicates how long
a device should wait before declaring the control channel dead.
The HelloDeadInterval parameter must be greater than the HelloInterval
parameter and should be at least three times the value of
HelloInterval. This field is used as the initial suggestion during the
negotiation of the hello dead interval, but may be overridden with a
per-control channel field.
This field can be set to zero to disable the LMP Hello
mechanism.
Context
- MIB
- DC-LMP-PROD
- OID
.1.3.6.1.4.1.629.10.5.1.1.1.11- Type
- column
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- dcLmpProductEntry
Syntax
milliseconds Unsigned32
Values & Constraints
No enumerated values or constraints recorded.