Enumeration
Has this circuit been configured by MIB (manual), I3
information (automatic) or both? MIB configuration
overrides I3 configuration.
Automatic circuits cannot be destroyed. Destroying a
manual circuit removes all configuration from that circuit
from DC-ISIS. Destroying a circuit in state 'both'
destroys any MIB configuration and returns the circuit to
automatic state.
Context
- MIB
- DC-ISIS-MIB
- OID
.1.3.6.1.4.1.629.10.10.1.3.2.1.23- Type
- column
- Access
- readonly
- Status
- current
- Parent
- isisCircEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | manual |
2 | automatic |
3 | both |