cyPMElecOutletTablePowerType
CYCLADES-ACS5K-PM-MIB ·
.1.3.6.1.4.1.2925.8.5.8.1.13
Object
column
Enumeration
The type of Power sensor for this elecmon
Context
- MIB
- CYCLADES-ACS5K-PM-MIB
- OID
.1.3.6.1.4.1.2925.8.5.8.1.13- Type
- column
- Access
- readonly
- Status
- current
- Parent
- cyPMElecOutletTableEntry
- Table
- cyPMElecOutletTable
- Siblings
- 14
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | estimated |
2 | measured |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cyPMElecOutletTablePortNumber Serial Port number where the PDU is connected. | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.2925.8.5.8.1.1 |
| cyPMElecOutletTableVoltageMax Maximum value of voltage in the Outlet (V). When Outlet does
not have voltage sensor, it returns 0. Write operation accepts
only 0 for reset action. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2925.8.5.8.1.10 |
| cyPMElecOutletTablePowerFactorValue Actual value of power factor in the Outlet (Pf x 10). When
Outlet does not have power factor sensor, returns 0. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2925.8.5.8.1.11 |
| cyPMElecOutletTablePowerFactorMax Maximum value of power factor in the Outlet (Pf x 10). When
Outlet does not have power factor sensor, returns 0.Write
operation accepts only 0 for reset action. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2925.8.5.8.1.12 |
| cyPMElecOutletTableVoltageType The type of Voltage sensor for this elecmon | column | Enumeration | .1.3.6.1.4.1.2925.8.5.8.1.14 |
| cyPMElecOutletTablePowerFactorType The type of Power Factor sensor for this elecmon | column | Enumeration | .1.3.6.1.4.1.2925.8.5.8.1.15 |
| cyPMElecOutletTablePduNumber The number of the PDU unit in the daisy-chained mode | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.2925.8.5.8.1.2 |
| cyPMElecOutletTableNumber outlet number in the PDU | column | IF-MIBInterfaceIndex | .1.3.6.1.4.1.2925.8.5.8.1.3 |
| cyPMElecOutletTableName name of the Outlet. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.2925.8.5.8.1.4 |
| cyPMElecOutletTableCurrentValue Actual value of current in the Outlet (A x 10). | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2925.8.5.8.1.5 |
| cyPMElecOutletTableCurrentMax Maximum detected value of current in the Outlet (A x 10).
Write operation accepts only 0 for reset action. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2925.8.5.8.1.6 |
| cyPMElecOutletTablePowerValue Actual value of power in the Outlet (W x 10). | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2925.8.5.8.1.7 |
| cyPMElecOutletTablePowerMax Maximum value of power in the Outlet (W x 10).Write operation
accepts only 0 for reset action. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2925.8.5.8.1.8 |
| cyPMElecOutletTableVoltageValue Actual value of voltage in the Outlet (V).When Outlet does
not have voltage sensor, it returns 0. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.2925.8.5.8.1.9 |