psPowerMinVoltage
CTRON-POWER-SUPPLY-MIB ·
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.10
Object
The minimum voltage for this power line. If the voltage reading for this power line is greater than this value then the power line is considered to be in an over volatge condition. The value of this object is voltage * 100.
Context
- MIB
- CTRON-POWER-SUPPLY-MIB
- OID
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.10- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- psPowerSlotEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::psPowerMinVoltage'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::psPowerMinVoltage.<psPowerSlotID>.<psPowerID>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CTRON-POWER-SUPPLY-MIB::psPowerMinVoltage'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647