CTRON-POWER-SUPPLY-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
5
Rows
5
Columns
39
.1.3.6.1.4.1.52.4.1.1.7.1.8
·
1 row entry
·
6 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk chPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::chPowerTable'
A list of power lines or busses on the chassis's backplane.
A slot entry containing objects for a particular
module and associated power line.
module and associated power line.
Indexes
| Column | Syntax | OID |
|---|---|---|
|
chPowerLineIDmandatory
A unique value used to identify a particular power line on
the chassis's backplane. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.1 |
|
chPowerLineTypemandatory
The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v. |
ObjectIdentifier | .1.3.6.1.4.1.52.4.1.1.7.1.8.1.2 |
|
chPowerLineTotalSupplymandatory
The total power being supplied by the chassis's power
supplies to the chassis on this power line. The value of this object is the actual watts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.3 |
|
chPowerLineTotalLoadmandatory
The total load being presented by the chassis to the
chassis's power supplies on this power line. This value will be zero if unknown The value of this object is the actual watts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.4 |
|
chPowerLineMaxSupplymandatory
The maximum power that could de supplied by the chassis's power
supplies to the chassison this power line. The value of this object is the actual watts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.5 |
|
chPowerLineMaxLoadmandatory
The maximum load that could be presented by the chassis to the
chassis's power supplies on this power line. The value of this object is the actual watts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.6 |
.1.3.6.1.4.1.52.4.1.1.7.2.1
·
1 row entry
·
9 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk boardPowerSlotStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::boardPowerSlotStatusTable'
A list of networking modules installed in this chassis.
A slot entry containing objects for a particular
module.
module.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
boardPowerSlotStatusIDmandatory
The slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the Chassis MIB. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.1 |
||||||||||||||||||||||
|
boardPowerOperationalStatusmandatory
This object reflects the status of the module's
DC-DC converter power supply. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.2 |
||||||||||||||||||||||
|
boardPowerAdminStatusmandatory
This object controls the operation of the module's
DC-DC power supply. If the value 3 is written to this object then the value of the object will be set to 1 after the reset is performed. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.3 |
||||||||||||||||||||||
|
boardPowerLocalAdminStatusmandatory
This object controls the operation of the module's
front panel button. In local mode this button may be used to locally control the operation of the DC-DC converter, i.e. power on, power off and reset. In secure mode … |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.4 |
||||||||||||||||||||||
|
boardPowerLocalStatusmandatory
This object reflects the state of the module's front
panel button. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.5 |
||||||||||||||||||||||
|
boardPowerShutdownAdminmandatory
This object controls whether or not the module should
auto power down due to an fault condition. |
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.6 |
||||||||||||||||||||||
|
boardPowerPrioritymandatory
The module's power-up and power down priority. This is a
value of 1 to 14 and is used to decide which modules are allowed to power on in the event that power demand of the chassis is greater than the total power supply.… |
Integer32r/w Constraints: range: 1-14 |
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.7 |
||||||||||||||||||||||
|
boardPowerMaxInputPowermandatory
The maximum input power that this module is allowed
to consume. The value of this object is actual watts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.8 |
||||||||||||||||||||||
|
boardPowerManagementmandatory
Module power management status.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.9 |
.1.3.6.1.4.1.52.4.1.1.7.2.2
·
1 row entry
·
9 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk boardPowerSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::boardPowerSlotTable'
A list of networking modules and associated power lines installed in this chassis.
A slot entry containing objects for a particular
module and associated power line.
module and associated power line.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
boardPowerSlotIDmandatory
The slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the Chassis MIB. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.1 |
||||||||||
|
boardPowerIDmandatory
A unique value used to identify a particular power line.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.2 |
||||||||||
|
boardPowerTypemandatory
The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v. |
ObjectIdentifier | .1.3.6.1.4.1.52.4.1.1.7.2.2.1.3 |
||||||||||
|
boardPowerStatusmandatory
This object reflects the status of this power line.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.4 |
||||||||||
|
boardPowerVoltagemandatory
The voltage reading for the power line. The value of this
object is actual voltage * 100. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.5 |
||||||||||
|
boardPowerCurrentmandatory
The current reading for the power line. The value of this
object is the actual amperage * 100. If this reading is not implemented then value will be zero. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.6 |
||||||||||
|
boardPowerMaxVoltagemandatory
The maximum voltage for this power line. If the voltage
reading for this power line is greater than this value then the power line is considered to be in an overvolatge condition. The value of this object is in voltage… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.7 |
||||||||||
|
boardPowerMinVoltagemandatory
The minimum voltage for this power line. If the voltage
reading for this power line is less than this value then the power line is considered to be in an undervolatge condition. The value of this object is voltage * 10… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.8 |
||||||||||
|
boardPowerMaxPowermandatory
The maximum power for this power line. If the power calculated
for this power line is greater than this value then the power line is considered to be in an overload condition. The value of this object is in watts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.9 |
.1.3.6.1.4.1.52.4.1.1.7.3.1
·
1 row entry
·
4 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk psPowerSlotStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::psPowerSlotStatusTable'
A list of AC & DC power supplies installed in this chassis.
A slot entry containing objects for a particular
power supply.
power supply.
Indexes
| Column | Syntax | OID | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
psPowerSlotStatusIDmandatory
The slot number of a chassis slot in which this AC power
supply is installed. This object is similiar to chSlotID in the Chassis MIB. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.1 |
||||||||||||||||||
|
psPowerOperationalStatusmandatory
This object reflects the status of the module's
DC-DC converter power supply. |
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.2 |
||||||||||||||||||
|
psPowerAdminStatusmandatory
This object controls the operation of power supply.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.3 |
||||||||||||||||||
|
psPowerMaxOutputPowermandatory
The maximum power that this power supply is allowed
to ouput. The value of this object is watts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.4 |
.1.3.6.1.4.1.52.4.1.1.7.3.2
·
1 row entry
·
11 columns
Uses the cabletron variant from
Command help
/opt/observium/mibs/cabletron.
Walk psPowerSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::psPowerSlotTable'
A list of power supplies and associated power lines installed in this chassis.
A slot entry containing objects for a particular
power line on a particular power supply.
power line on a particular power supply.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
psPowerSlotIDmandatory
The slot number of a chassis slot in which this Power
supply is installed. This object is similiar to chSlotID in the Chassis MIB. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.1 |
||||||||||
|
psPowerIDmandatory
A unique value used to identify a particular power line.
|
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.2 |
||||||||||
|
psPowerTypemandatory
The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a power line that supplies AC current at a nominal volatge of 110v. |
ObjectIdentifier | .1.3.6.1.4.1.52.4.1.1.7.3.2.1.3 |
||||||||||
|
psPowerStatusmandatory
This object reflects the status of the power line.
|
Enumeration Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.4 |
||||||||||
|
psPowerAdminmandatory
This object controls the operation of power supply.
|
Enumerationr/w Enumerated Values:
|
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.5 |
||||||||||
|
psPowerVoltagemandatory
The voltage reading for the power line. The value of this
object is the actual voltage * 100. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.6 |
||||||||||
|
psPowerCurrentmandatory
The current reading for the power line. The value of this
object is amperage * 100. If this reading is not implemented then value will be zero. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.7 |
||||||||||
|
psPowerLineFrequencymandatory
The line frequency for the power line. The value of this
object is the actual frequency in Hertz * 10. If this reading is not implemented then value will be zero. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.8 |
||||||||||
|
psPowerMaxVoltagemandatory
The maximum voltage for this power line. If the voltage
reading for this power line is greater than this value then the power line is considered to be in an over volatge condition. The value of this object is voltage *… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.9 |
||||||||||
|
psPowerMinVoltagemandatory
The minimum voltage for this power line. If the voltage
reading for this power line is greater than this value then the power line is considered to be in an over volatge condition. The value of this object is voltage *… |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.10 |
||||||||||
|
psPowerMaxPowermandatory
The maximum power for this power line. If the power calculated
for this power line is greater than this value then the power line is considered to be in an overload condition. The value of this object is watts. |
Integer32 Type Constraints: range: -2147483648..2147483647 |
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.11 |