CTRON-POWER-SUPPLY-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
5
Rows
5
Columns
39

chPowerTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.7.1.8 · 1 row entry · 6 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk chPowerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::chPowerTable'
A list of power lines or busses on the chassis's backplane.
chPowerEntry row .1.3.6.1.4.1.52.4.1.1.7.1.8.1
A slot entry containing objects for a particular
module and associated power line.
Indexes
Column Syntax OID
chPowerLineIDmandatory
A unique value used to identify a particular power line on
the chassis's backplane.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.1
The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.1.7.1.8.1.2
The total power being supplied by the chassis's power
supplies to the chassis on this power line. The value
of this object is the actual watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.3
The total load being presented by the chassis to the
chassis's power supplies on this power line. This value
will be zero if unknown The value of this object is the
actual watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.4
The maximum power that could de supplied by the chassis's power
supplies to the chassison this power line. The value of
this object is the actual watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.5
The maximum load that could be presented by the chassis to the
chassis's power supplies on this power line. The value of
this object is the actual watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.1.8.1.6

boardPowerSlotStatusTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.7.2.1 · 1 row entry · 9 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk boardPowerSlotStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::boardPowerSlotStatusTable'
A list of networking modules installed in this chassis.
boardPowerSlotStatusEntry row .1.3.6.1.4.1.52.4.1.1.7.2.1.1
A slot entry containing objects for a particular
module.
Column Syntax OID
The slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the
Chassis MIB.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.1
This object reflects the status of the module's
DC-DC converter power supply.
Enumeration
Enumerated Values:
1powerOn
2powerOff
3reset
4overVoltage
5underVoltage
6overCurrent
7overCurrentShutdown
8temperatureShutdown
9remotePowerOff
10powerConservationShutdown
11frontPanelPowerOff
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.2
This object controls the operation of the module's
DC-DC power supply. If the value 3 is written to
this object then the value of the object will be
set to 1 after the reset is performed.
Enumerationr/w
Enumerated Values:
1powerOn
2powerOff
3reset
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.3
This object controls the operation of the module's
front panel button. In local mode this button may
be used to locally control the operation of the
DC-DC converter, i.e. power on, power off and
reset. In secure mode …
Enumerationr/w
Enumerated Values:
1localMode
2secureMode
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.4
This object reflects the state of the module's front
panel button.
Enumeration
Enumerated Values:
1resetRequest
2powerDownRequest
3powerOnRequest
4normal
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.5
This object controls whether or not the module should
auto power down due to an fault condition.
Enumerationr/w
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.6
The module's power-up and power down priority. This is a
value of 1 to 14 and is used to decide which modules are
allowed to power on in the event that power demand of the
chassis is greater than the total power supply.…
Integer32r/w
Constraints:
range: 1-14
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.7
The maximum input power that this module is allowed
to consume. The value of this object is actual
watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.8
Module power management status.
Enumerationr/w
Enumerated Values:
1disabled
2enabled
7not-supported
.1.3.6.1.4.1.52.4.1.1.7.2.1.1.9

boardPowerSlotTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.7.2.2 · 1 row entry · 9 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk boardPowerSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::boardPowerSlotTable'
A list of networking modules and associated power lines 
installed in this chassis.
boardPowerSlotEntry row .1.3.6.1.4.1.52.4.1.1.7.2.2.1
A slot entry containing objects for a particular
module and associated power line.
Column Syntax OID
The slot number of a chassis slot in which this board is
installed. This object is similiar to chSlotID in the
Chassis MIB.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.1
boardPowerIDmandatory
A unique value used to identify a particular power line.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.2
The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.1.7.2.2.1.3
This object reflects the status of this power line.
Enumeration
Enumerated Values:
1powerOK
2powerOff
3overCurrent
4overVoltage
5underVoltage
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.4
The voltage reading for the power line. The value of this
object is actual voltage * 100.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.5
The current reading for the power line. The value of this
object is the actual amperage * 100. If this reading is not
implemented then value will be zero.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.6
The maximum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an overvolatge
condition. The value of this object is in voltage…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.7
The minimum voltage for this power line. If the voltage
reading for this power line is less than this value
then the power line is considered to be in an undervolatge
condition. The value of this object is voltage * 10…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.8
The maximum power for this power line. If the power calculated
for this power line is greater than this value then the
power line is considered to be in an overload condition.
The value of this object is in watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.2.2.1.9

psPowerSlotStatusTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.7.3.1 · 1 row entry · 4 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk psPowerSlotStatusTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::psPowerSlotStatusTable'
A list of AC & DC power supplies installed in this chassis.
psPowerSlotStatusEntry row .1.3.6.1.4.1.52.4.1.1.7.3.1.1
A slot entry containing objects for a particular
power supply.
Column Syntax OID
The slot number of a chassis slot in which this AC power
supply is installed. This object is similiar
to chSlotID in the Chassis MIB.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.1
This object reflects the status of the module's
DC-DC converter power supply.
Enumeration
Enumerated Values:
1powerOn
2powerOff
3reset
4overVoltage
5underVoltage
6overCurrent
7overCurrentShutdown
8temperatureShutdown
9remotePowerOff
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.2
This object controls the operation of power supply.
Enumerationr/w
Enumerated Values:
1powerOn
2powerOff
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.3
The maximum power that this power supply is allowed
to ouput. The value of this object is watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.1.1.4

psPowerSlotTable

table mandatory
.1.3.6.1.4.1.52.4.1.1.7.3.2 · 1 row entry · 11 columns
Uses the cabletron variant from /opt/observium/mibs/cabletron.
Command help
Walk psPowerSlotTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::psPowerSlotTable'
A list of power supplies and associated power lines
installed in this chassis.
psPowerSlotEntry row .1.3.6.1.4.1.52.4.1.1.7.3.2.1
A slot entry containing objects for a particular
power line on a particular power supply.
Column Syntax OID
psPowerSlotIDmandatory
The slot number of a chassis slot in which this Power
supply is installed. This object is similiar to
chSlotID in the Chassis MIB.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.1
psPowerIDmandatory
A unique value used to identify a particular power line.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.2
psPowerTypemandatory
The type of power. For example, a power line that supplies
DC current at a nominal voltage of 40 to 57 volts or a
power line that supplies AC current at a nominal volatge of
110v.
ObjectIdentifier .1.3.6.1.4.1.52.4.1.1.7.3.2.1.3
psPowerStatusmandatory
This object reflects the status of the power line.
Enumeration
Enumerated Values:
1powerOK
2powerOff
3overCurrent
4overVoltage
5underVoltage
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.4
psPowerAdminmandatory
This object controls the operation of power supply.
Enumerationr/w
Enumerated Values:
1powerOn
2powerOff
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.5
The voltage reading for the power line. The value of this
object is the actual voltage * 100.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.6
The current reading for the power line. The value of this
object is amperage * 100. If this reading is not implemented
then value will be zero.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.7
The line frequency for the power line. The value of this
object is the actual frequency in Hertz * 10. If this
reading is not implemented then value will be zero.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.8
The maximum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an over volatge
condition. The value of this object is voltage *…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.9
The minimum voltage for this power line. If the voltage
reading for this power line is greater than this value
then the power line is considered to be in an over volatge
condition. The value of this object is voltage *…
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.10
The maximum power for this power line. If the power calculated
for this power line is greater than this value then the
power line is considered to be in an overload condition.
The value of this object is watts.
Integer32
Type Constraints:
range: -2147483648..2147483647
.1.3.6.1.4.1.52.4.1.1.7.3.2.1.11