chPowerDiagVoltage
CTRON-POWER-SUPPLY-MIB ·
.1.3.6.1.4.1.52.4.1.1.7.1.10
Object
The voltage of the chassis's diag voltage rail. This rail carries power to all the modules in the chassis. It has an allowable range of 4.75 volts to 5.25 volts DC. The value of this object is the actual voltage * 10.
Context
- MIB
- CTRON-POWER-SUPPLY-MIB
- OID
.1.3.6.1.4.1.52.4.1.1.7.1.10- Type
- scalar
- Access
- readonly
- Status
- mandatory
- Parent
- chPower
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CTRON-POWER-SUPPLY-MIB::chPowerDiagVoltage.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CTRON-POWER-SUPPLY-MIB' -M '/opt/observium/mibs/cabletron:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CTRON-POWER-SUPPLY-MIB::chPowerDiagVoltage'
Syntax
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647