upsLoadShedSecsWithRestart
CPQPOWER-MIB ·
.1.3.6.1.4.1.232.165.3.8.6
Object
scalar
mandatory
r/w
Integer32
Setting this value will cause the UPS output to turn off after the set number of seconds, then restart (after a UPS-defined 'down time') when the utility is again available. Unlike UpsControlOutputOffDelay, which might or might not, this object always maps to the XCP 0x8A Load Dump & Restart command, so the desired shutdown and restart behavior is guaranteed to happen. Once set, this command cannot be aborted. This is the preferred Control object to use when performing an On Battery OS Shutdown.
Context
- MIB
- CPQPOWER-MIB
- OID
.1.3.6.1.4.1.232.165.3.8.6- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- upsControl
Syntax
Integer32
Values & Constraints
Object Constraints
range: 0-2147483647