CPQPOWER-MIB Table View
Table-centric layout grouping table, row, and column objects.
Tables
41
Rows
41
Columns
485
.1.3.6.1.4.1.232.165.2.1.2
·
1 row entry
·
9 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pduIdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pduIdentTable'
The Aggregate Object with number of entries equal to NumOfPdu and including the PduIdent group.
The ident table entry containing the name,
model, manufacturer, firmware version, part number, etc.
model, manufacturer, firmware version, part number, etc.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
pduIdentIndexmandatory Index for the PduIdentEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.2.1.2.1.1 | ||||||||
pduNamemandatory The string identify the device. | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.2.1.2.1.2 | ||||||||
pduModelmandatory The Device Model. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.2.1.2.1.3 | ||||||||
pduManufacturermandatory The Device Manufacturer Name (e.g. Hewlett-Packard). | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.2.1.2.1.4 | ||||||||
pduFirmwareVersionmandatory The firmware revision level of the device. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.2.1.2.1.5 | ||||||||
pduPartNumbermandatory The device part number. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.2.1.2.1.6 | ||||||||
pduSerialNumbermandatory The device serial number. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.2.1.2.1.7 | ||||||||
pduStatusmandatory The overall status of the device. A value of OK(2) indicates the device is operating normally.A value of degraded(3) indicates the device is operating with warning indicators. A value of failed(4) indicates the devic… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.2.1.2.1.8 | ||||||||
pduControllablemandatory This object indicates whether or not the device is controllable. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.2.1.2.1.9 |
.1.3.6.1.4.1.232.165.2.2.1
·
1 row entry
·
3 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pduInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pduInputTable'
The Aggregate Object with number of entries equal to NumOfPdu and including the PduInput group.
The input table entry containing the voltage and
current for the PDU
current for the PDU
Indexes
| Column | Syntax | OID |
|---|---|---|
pduInputIndexmandatory Index for the PduInputEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.2.2.1.1.1 |
inputVoltagemandatory The measured input voltage from the PDU meters in volts. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.2.2.1.1.2 |
inputCurrentmandatory The measured input current from the PDU meters in hundredths of Amp. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.2.2.1.1.3 |
.1.3.6.1.4.1.232.165.2.3.1
·
1 row entry
·
5 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pduOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pduOutputTable'
The Aggregate Object with number of entries equal to NumOfPdu and including the PduInput group.
The input table entry containing the name,
heat load, current load, power load, firmware, etc.
heat load, current load, power load, firmware, etc.
Indexes
| Column | Syntax | OID |
|---|---|---|
pduOutputIndexmandatory Index for the PduOutputEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.2.3.1.1.1 |
pduOutputLoadmandatory The device output load in percent of rated capacity. A value of -1 will bereturned if the heat load is unable to be measured. | Integer32 Constraints: range: 0-200 | .1.3.6.1.4.1.232.165.2.3.1.1.2 |
pduOutputHeatmandatory The total heat load measured on the PDU in BTUs. A value of -1 will bereturned if the heat load is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.2.3.1.1.3 |
pduOutputPowermandatory The total power load measured on the PDU in watts. A value of -1 will bereturned if the power load is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.2.3.1.1.4 |
pduOutputNumBreakersmandatory The number of breakers for the device. This variable indicates the number of rows in the breakers table. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.2.3.1.1.5 |
.1.3.6.1.4.1.232.165.2.3.2
·
1 row entry
·
5 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pduOutputBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pduOutputBreakerTable'
List of breaker table entries. The number of entries is given by pduOutputNumBreakers .
An entry containing information applicable to an breaker.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
breakerIndexmandatory The breaker identifier. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.2.3.2.1.1 | ||||||||||
breakerVoltagemandatory The breaker voltage in volts. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.2.3.2.1.2 | ||||||||||
breakerCurrentmandatory The breaker current draw in hundredths of Amp. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.2.3.2.1.3 | ||||||||||
breakerPercentLoadmandatory The breaker load in percent. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.2.3.2.1.4 | ||||||||||
breakerStatusmandatory This object indicates the status of the breaker. A value of normal(1)indicates the breaker is operating normally. A value of overloadWarning(2) indicates the breaker has an overload warning. A value of overloadCriti… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.2.3.2.1.5 |
.1.3.6.1.4.1.232.165.3.3.4
·
1 row entry
·
4 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk upsInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::upsInputTable'
The Aggregate Object with number of entries equal to NumPhases and including the UpsInput group.
The input table entry containing the current, voltage, etc.
Indexes
| Column | Syntax | OID |
|---|---|---|
upsInputPhasemandatory The number of the phase. Serves as index for input table. | Integer32 Constraints: range: 0-6 | .1.3.6.1.4.1.232.165.3.3.4.1.1 |
upsInputVoltagemandatory The measured input voltage from the UPS meters in volts. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.3.3.4.1.2 |
upsInputCurrentmandatory The measured input current from the UPS meters in amps. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.3.3.4.1.3 |
upsInputWattsmandatory The measured input real power in watts. Most UPSs do not reportthis XCP data | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.3.3.4.1.4 |
.1.3.6.1.4.1.232.165.3.4.4
·
1 row entry
·
4 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk upsOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::upsOutputTable'
The Aggregate Object with number of entries equal to NumPhases and including the UpsOutput group.
Output Table Entry containing voltage, current, etc.
Indexes
| Column | Syntax | OID |
|---|---|---|
upsOutputPhasemandatory The number {1..3} of the output phase. | Integer32 Constraints: range: 0-6 | .1.3.6.1.4.1.232.165.3.4.4.1.1 |
upsOutputVoltagemandatory The measured output voltage from the UPS metering in volts. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.3.4.4.1.2 |
upsOutputCurrentmandatory The measured UPS output current in amps. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.3.4.4.1.3 |
upsOutputWattsmandatory The measured real output power in watts. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.3.4.4.1.4 |
.1.3.6.1.4.1.232.165.3.5.3
·
1 row entry
·
2 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk upsBypassTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::upsBypassTable'
Entry in the UpsBypassTable.
Indexes
| Column | Syntax | OID |
|---|---|---|
upsBypassPhasemandatory The Bypass Phase, index for the table. | Integer32 Constraints: range: 0-6 | .1.3.6.1.4.1.232.165.3.5.3.1.1 |
upsBypassVoltagemandatory The measured UPS bypass voltage in volts. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.3.5.3.1.2 |
.1.3.6.1.4.1.232.165.3.6.8
·
1 row entry
·
4 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk upsContactsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::upsContactsTable'
A list of Contact Sensing table entries. The number of entries is given by the value of UpsEnvNumContacts.
An entry containing information applicable
to a particular Contact input.
to a particular Contact input.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
upsContactIndexmandatory The Contact identifier; identical to the Contact Number. | Integer32 Constraints: range: 1-1024 | .1.3.6.1.4.1.232.165.3.6.8.1.1 | ||||||||
upsContactTypemandatory The normal state for this contact. The 'other'state is the Active state for generating the UpstdContactActiveNotice trap. If anyChange(3) is selected, then this trap is sent any time the contact changes to either Ope… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.3.6.8.1.2 | ||||||||
upsContactStatemandatory The current state of the Contact input;the value is based on the open/closed input state and the setting for UpsContactType. When entering the openWithNotice(3) and closedWithNotice(4) states, no entries added to the… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.3.6.8.1.3 | ||||||||
upsContactDescrmandatory A label identifying the Contact. This object should beset by the administrator. | OctetStringr/w Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.3.6.8.1.4 |
.1.3.6.1.4.1.232.165.3.10.2
·
1 row entry
·
7 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk upsRecepTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::upsRecepTable'
The Aggregate Object with number of entries equal to NumReceptacles and including the UpsRecep group.
The Recep table entry, etc.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
upsRecepIndexmandatory The number of the Receptacle. Serves as index for Receptacle table. | Integer32 Constraints: range: 1-64 | .1.3.6.1.4.1.232.165.3.10.2.1.1 | ||||||||||
upsRecepStatusmandatory The Recep Status 1=On/Close, 2=Off/Open, 3=On w/Pending Off, 4=Off w/Pending ON, 5=Unknown. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.3.10.2.1.2 | ||||||||||
upsRecepOffDelaySecsmandatory The Delay until the Receptacle is turned Off. Setting this value to other than -1 will cause the UPS output to turn off after the number of seconds (0 is immediately). Setting it to -1 will cause an attempt to abor… | Integer32r/w Constraints: range: -1-2147483647 | .1.3.6.1.4.1.232.165.3.10.2.1.3 | ||||||||||
upsRecepOnDelaySecsmandatory The Delay until the Receptacle is turned On. Setting this value to other than -1 will cause the UPS output to turn on after the number of seconds (0 is immediately). Setting it to -1 will cause an attempt to abort … | Integer32r/w Constraints: range: -1-2147483647 | .1.3.6.1.4.1.232.165.3.10.2.1.4 | ||||||||||
upsRecepAutoOffDelaymandatory The delay after going On Battery until the Receptacle is automatically turned Off. A value of -1 means that this Output should never be turned Off automatically, but must be turned Off only by command. Values from 0 … | Integer32r/w Constraints: range: -1-32767 | .1.3.6.1.4.1.232.165.3.10.2.1.5 | ||||||||||
upsRecepAutoOnDelaymandatory Seconds delay after the Outlet is signaled to turn On before the Output isAutomatically turned ON. A value of -1 means that this Output should never be turned On automatically, but only when specifically commanded to d… | Integer32r/w Constraints: range: -1-32767 | .1.3.6.1.4.1.232.165.3.10.2.1.6 | ||||||||||
upsRecepShedSecsWithRestartmandatory Setting this value will cause the UPS output to turn off after the set number of seconds, then restart (after a UPS-defined 'down time') when the utility is again available. Unlike UpsRecepOffDelaySecs, which might o… | Integer32r/w Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.3.10.2.1.7 |
.1.3.6.1.4.1.232.165.4.2.1
·
1 row entry
·
16 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdrPanelTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdrPanelTable'
Aggregate Object with number of entries equal to pdrNumPanels
The panel table entry containing all power parameters
for each panel.
for each panel.
Indexes
| Column | Syntax | OID |
|---|---|---|
pdrPanelIndexmandatory Index for the pdrPanelEntry table. | Integer32 Constraints: range: 0-10 | .1.3.6.1.4.1.232.165.4.2.1.1.1 |
pdrPanelFrequencymandatory The present frequency reading for the panel voltage. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.2 |
pdrPanelPowermandatory The present power of the panel. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.3 |
pdrPanelRatedCurrentmandatory The present rated current of the panel. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.4 |
pdrPanelMonthlyKWHmandatory The accumulated KWH for this panel since the beginning of this calendar month or since the last reset. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.5 |
pdrPanelYearlyKWHmandatory The accumulated KWH for this panel since the beginning of this calendar year or since the last reset. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.6 |
pdrPanelTotalKWHmandatory The accumulated KWH for this panel since it was put into service or since the last reset. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.7 |
pdrPanelVoltageAmandatory The measured panel output voltage. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.8 |
pdrPanelVoltageBmandatory The measured panel output voltage. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.9 |
pdrPanelVoltageCmandatory The measured panel output voltage. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.10 |
pdrPanelCurrentAmandatory The measured panel output current. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.11 |
pdrPanelCurrentBmandatory The measured panel output current. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.12 |
pdrPanelCurrentCmandatory The measured panel output current. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.2.1.1.13 |
pdrPanelLoadAmandatory The percentage of load is the ratio of each output current to the rated output current to the panel. | Integer32 Constraints: range: 0-200 | .1.3.6.1.4.1.232.165.4.2.1.1.14 |
pdrPanelLoadBmandatory The percentage of load is the ratio of each output current to the rated output current to the panel. | Integer32 Constraints: range: 0-200 | .1.3.6.1.4.1.232.165.4.2.1.1.15 |
pdrPanelLoadCmandatory The percentage of load is the ratio of each output current to the rated output current to the panel. | Integer32 Constraints: range: 0-200 | .1.3.6.1.4.1.232.165.4.2.1.1.16 |
.1.3.6.1.4.1.232.165.4.3.1
·
1 row entry
·
14 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdrBreakerTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdrBreakerTable'
List of breaker table entries. The number of entries is given by pdrNumBreakers for this panel.
An entry containing information applicable to a
particular output breaker of a particular panel.
particular output breaker of a particular panel.
Indexes
| Column | Syntax | OID |
|---|---|---|
pdrBreakerIndexmandatory The index of breakers. 42 breakers in each panel,arranged in odd and even columns | Integer32 Constraints: range: 0-200 | .1.3.6.1.4.1.232.165.4.3.1.1.1 |
pdrBreakerPanelmandatory The index of panel that these breakers are installed on. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.2 |
pdrBreakerNumPositionmandatory The position of this breaker in the panel, 1-phase breakeror n-m breaker for 2-phase or n-m-k breaker for 3-phase. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.3 |
pdrBreakerNumPhasesmandatory The number of phase for this particular breaker. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.4 |
pdrBreakerNumSequencemandatory The sequence of this breaker. i.e. 1 for single phase1,2 for 2-phase or 1,2,3 for 3-phase. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.5 |
pdrBreakerRatedCurrentmandatory The rated current in Amps for this particular breaker. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.6 |
pdrBreakerMonthlyKWHmandatory The accumulated KWH for this breaker since the beginning of this calendar month or since the last reset. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.7 |
pdrBreakerYearlyKWHmandatory The accumulated KWH for this breaker since the beginning of this calendar year or since the last reset. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.8 |
pdrBreakerTotalKWHmandatory The accumulated KWH for this breaker since it was put into service or since the last reset. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.9 |
pdrBreakerCurrentmandatory The measured output current for this breaker Current. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.10 |
pdrBreakerCurrentPercentmandatory The ratio of output current over rated current for each breaker. | Integer32 Constraints: range: 0-200 | .1.3.6.1.4.1.232.165.4.3.1.1.11 |
pdrBreakerPowermandatory The power for this breaker in Watts. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.12 |
pdrBreakerPercentWarningmandatory The percentage of Warning set for this breaker. | Integer32 Constraints: range: 0-200 | .1.3.6.1.4.1.232.165.4.3.1.1.13 |
pdrBreakerPercentOverloadmandatory The percentage of Overload set for this breaker. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.4.3.1.1.14 |
.1.3.6.1.4.1.232.165.5.1.2
·
1 row entry
·
41 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk mpduIdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::mpduIdentTable'
Indexed by mpduNumMPDU. So aggregate objects for each entry equal to mpduNumMPDU before go to the next entry. i.e if 4 MPDU detected, display 4 indexes, 4 Manufacturers, 4 Models..., start with 1.
The table entry containing the identifications of each MPDU as well
as names of PDR panel, location of MPDU in a Data Center.
as names of PDR panel, location of MPDU in a Data Center.
Indexes
| Column | Syntax | OID |
|---|---|---|
mpduIdentIndexmandatory Index for the MpduIdentEntry table. Start with 1 | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.5.1.2.1.1 |
mpduManufacturermandatory The Core PDU manufacturer. StringLength=[21] | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.2 |
mpduModelmandatory The Core PDU model, marketing name. StringLength=[40]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.3 |
mpduNamemandatory The Core PDU name, descriptive name or hostname. StringLength=[16]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.4 |
mpduFirmwareVersionmandatory The Core PDU firmware version(s). StringLength=[12]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.5 |
mpduHardwareVersionmandatory The Core PDU hardware version. StringLength=[8]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.6 |
mpduPartNumbermandatory The Core PDU part number. StringLength=[21]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.7 |
mpduSerialNumbermandatory The PDU external serial number. StringLength=[21]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.8 |
mpduUUIDmandatory The PDU's UUID equals PN add SN then canonical conversion. StringLength=[37]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.9 |
mpduIPmandatory The PDU's assigned IP. StringLength=[16]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.10 |
mpduMACAddressmandatory The Core PDU MAC address. StringLength=[18]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.11 |
mpduControlStatusmandatory The Core PDU Control Status: master or slave units.StringLength=[31]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.12 |
mpduRegionmandatory The PDU's Region: NA, Intl, Japan... StringLength=[7]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.13 |
mpduTypemandatory The PDU's Type: Delta, Wye, single, Wye+lowline.StringLength=[24]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.14 |
mpduPowerRatingmandatory The PDU's Power Rating in KVA (Name Plate). Value is presented in 1/100 of the KVA. i.e. 1750 means 17.50 KVA | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.15 |
mpduInputRatingmandatory The PDU's Input Current Rating in A (Name Plate) | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.16 |
mpduInputPlugmandatory The PDU's Input Plug: IEC60309 516P6,NEMA L15-30P...StringLength=[16]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.17 |
mpduNumBreakersmandatory The number of breakers used in each MPDU (6 by default). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.1.2.1.18 |
mpduNumOutletmandatory The number of outlets of each MPDU (6 by default). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.1.2.1.19 |
mpduUHeightmandatory The MPDU U Height 1U or 2 U (1U by default). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.1.2.1.20 |
mpduRedundantStatusmandatory Status of Core PDU in paired or not: Stand-alone or Redundant.StringLength=[12]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.21 |
mpduNumSmartExtBarmandatory total number of detected Smart Sticks connecting to each PDU. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.1.2.1.22 |
mpduPanelNamemandatory Name of Panel that was entered by customer in GUI.StringLength=[50]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.23 |
mpduPanelBreakerNamemandatory Name of breakers or Panel Position entered by customer in GUI.StringLength=[50]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.24 |
mpduPanelBreakerRatingmandatory Breaker rating of the PDR Panel. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.25 |
mpduACFeedNamemandatory it would be A, B, Red, or White...StringLength=[50]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.26 |
mpduFloorNamemandatory Name of building floor entered by customer in GUI.StringLength=[50]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.27 |
mpduRoomNamemandatory Name of the room entered by customer in GUI. StringLength=[50]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.28 |
mpduRowmandatory Data Center Row entered by customer in GUI.StringLength=[11]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.29 |
mpduRowPositionmandatory Position in Row entered by customer in GUI. Null will be returned if not detected. StringLength=[11]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.30 |
mpduRackNamemandatory Name of the Rack entered by customer in GUI. Null will be returned if not detected. StringLength=[50]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.31 |
mpduRackHeightmandatory Rack Type (22U, 42U, 50U...). Null will be returned if not detected.StringLength=[3]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.32 |
mpduRackIDmandatory An unique ID to identify a rack, i.e. Rack SN. Null will be returned if not detected. StringLength=[50]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.33 |
mpduUPositionmandatory PDU Rack bottom U Start position, core U position. Null will be returned if not detected. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.1.2.1.34 |
mpduPairedPDUUUIDmandatory UUID of the PDU paired with this one. Null will be returned if not detected.StringLength=[50]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.35 |
mpduPairedPDUIPmandatory IP address of the PDU paired with this one. Null will be returned if not detected.StringLength=[16]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.36 |
mpduInstalledLocationmandatory 0=Left 0U side area or rack frame, 1= Right 0U side area or rack frame, 2= front RETMA rail, 3=back RETMA rail) - spatial location. A value of -1 will be returned if not detected. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.1.2.1.37 |
mpduTotalPowerWattmandatory The total power for the whole iPDU in Watts. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.1.2.1.38 |
mpduTotalPowerVAmandatory The total power for the whole iPDU in VA. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.1.2.1.39 |
mpduTotalPercentLoadmandatory The whole iPDU's load in percent of rated capacity. Value is presented in 1/10 of the percentage i.e. 125 is 12.5%. A value of -1 will be returned if the current is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.1.2.1.40 |
mpduRegionalNominalVoltagemandatory value is either America(208V), Japan(202V) or blank for International Model | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.1.2.1.41 |
.1.3.6.1.4.1.232.165.5.2.1
·
1 row entry
·
13 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk mpduOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::mpduOutputTable'
Indexed by mpduNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU multiplies mpduNumOutlet) before go to the next entry. i.e if 4 MPDU detected, display 6x4 indexes, 6x4 OutputStatus, 6x4 OutputBreakerRating...start with 1.
The output table entry containing the voltage, current, PF,
percent load, VA, Watts for the Modular PDU.
percent load, VA, Watts for the Modular PDU.
Indexes
| Column | Syntax | OID |
|---|---|---|
mpduOutputIndexmandatory Index for the MpduOutputEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.5.2.1.1.1 |
mpduOutputStatusmandatory The overall status of the device: off, on, problem. StringLength=[7]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.2.1.1.2 |
mpduOutputBreakerRatingmandatory The rating of each MPDU Output in Ampere. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.3 |
mpduOutputSmartDevicemandatory A smart cord device detected: False, True. StringLength=[5]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.2.1.1.4 |
mpduOutputPercentLoadmandatory The MPDU's each output load in percent of rated capacity. Value is presented in 1/10 of the percentage i.e. 125 is 12.5%. A value of -1 will be returned if the current is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.5 |
mpduOutputVoltagemandatory The measured output voltage from the PDU meters in volts. Value is presented in 1/10 of the Volt i.e. 2095 is 209.5 V. A value of -1 will be returned if the voltage is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.6 |
mpduOutputCurrentmandatory The measured output current from the PDU meters in amps. Value is presented in 1/100 of the Ampere i.e. 175 is 1.75 A. A value of -1 will be returned if the current is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.7 |
mpduOutputPowerVAmandatory The total VA load (VI) measured on the PDU in VA. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.8 |
mpduOutputPowerWattmandatory The total power load measured on the PDU in Watts. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.9 |
mpduOutputPowerFactormandatory The power factor is presented in 1/100 of the unit i.e.98 is 0.98. A value of -1 will be returned if the power factor is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.10 |
mpduOutputWarningThresholdmandatory Report the User-set threshhold limit for Warning in percentage | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.11 |
mpduOutputCriticalThresholdmandatory Report the User-set threshhold limit for Critical in percentage | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.12 |
mpduOutputPowerWattHourmandatory Support Billing Grade Energy Metering in Watt-Hour. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.2.1.1.13 |
.1.3.6.1.4.1.232.165.5.3.1
·
1 row entry
·
20 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk mpduDeviceIdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::mpduDeviceIdentTable'
Indexed by mpduNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU multiplies mpduNumOutlet) before go to the next entry. i.e if 4 MPDU detected, display 6x4 indexes, 6x4 mpduDeviceStatus, 6x4 DeviceUIDStatus...start with 1.
The ident table entry containing the name, model,
manufacturer, firmware version, part number... for
each smart device, null value for unknown device.
manufacturer, firmware version, part number... for
each smart device, null value for unknown device.
Indexes
| Column | Syntax | OID |
|---|---|---|
mpduDeviceIdentIndexmandatory Index is based on the total number of Smart Extension Bars plussmart devices (with smart power cord i.e. blades) detected. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.5.3.1.1.1 |
mpduDeviceStatusmandatory The overall status of the device: off, on, problem. StringLength=[8]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.2 |
mpduDeviceUIDStatusmandatory The overall status of the device UID: off, on, blink. StringLength=[8]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.3 |
mpduDeviceNumOutletmandatory The number of outlets of detected the device. This variable indicates the number of rows in the breakers table. Default is 5 | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.3.1.1.4 |
mpduDeviceUHeightmandatory The Unit height of ext bar or device. Some device supports non-integer. Present value x100, when read back, divided by 100 to get 2 decimal points. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.3.1.1.5 |
mpduDevicePowerRatingmandatory The device's Power Rating in VA. Null will be returned if not detected.StringLength=[8]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.6 |
mpduDeviceManufacturermandatory The Device Manufacturer Name (e.g. Hewlett-Packard).Null will be returned if not detected. StringLength=[16]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.7 |
mpduDeviceTypemandatory The Device's Type: Ext Bar, server, or network device...StringLength=[16]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.8 |
mpduDeviceModelmandatory The Device Model is Managed or Non-managed Ext Bar. Null will be returned if not detected. StringLength=[24]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.9 |
mpduDeviceNamemandatory The string identify the Device. i.e. 'BAR#1' (descriptive name)Null will be returned if not detected. StringLength=[32]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.10 |
mpduDeviceFirmwareVersionmandatory The firmware revision level of Sm Ext Bar. Null will be returned if not detected. StringLength=[8]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.11 |
mpduDeviceHardwareVersionmandatory The hardware version of Sm Ext Bar. Null will be returned if not detected. StringLength=[8]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.12 |
mpduDevicePartNumbermandatory The device's part number. Null will be returned if not detected.StringLength=[21]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.13 |
mpduDeviceSerialNumbermandatory The device's serial number. Null will be returned if not detected.StringLength=[21]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.14 |
mpduDeviceUUIDmandatory The device's UUID. Null will be returned if not detected.StringLength=[37]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.15 |
mpduDeviceIPmandatory The device's IP Address. Null will be returned if not detected.StringLength=[16]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.16 |
mpduDeviceMACmandatory The device mgmt processor MAC Address. Null will be returned if not detected. StringLength=[18]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.3.1.1.17 |
mpduDevicePSUSlotNomandatory Device power supply logical slot number. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.3.1.1.18 |
mpduDeviceUPositionmandatory Device U start position. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.3.1.1.19 |
mpduDeviceDetectionThresholdmandatory Read device detection threshold between 10 and 50mA. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.3.1.1.20 |
.1.3.6.1.4.1.232.165.5.4.1
·
1 row entry
·
20 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk mpduSmExtBarOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::mpduSmExtBarOutletTable'
Indexed by mpduDeviceNumOutlet. So aggregate objects for each entry equal to (mpduNumMPDU multiplies mpduNumOutlet multiplies mpduDeviceNumOutlet) before go to the next entry. i.e if 4 MPDU detected, display 5x6x4 indexes, 5x6x4 mpduSmExtBarOutletStatus, 5x6x4 mpduSmExtBarOutletUIDStatus...start with 1.
Entries contain status, measurements for each outlet (no PowerVA)
Display null if it can't be measured or no device detected.
Display null if it can't be measured or no device detected.
| Column | Syntax | OID |
|---|---|---|
mpduSmExtBarOutletIndexmandatory The Index of Smart Extension Bar. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.5.4.1.1.1 |
mpduSmExtBarOutletStatusmandatory The overall status of the Smart Extension Bar's outlet: off, on, problem...StringLength=[3]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.4.1.1.2 |
mpduSmExtBarOutletUIDStatusmandatory The overall status of the Smart Extension Bar's UID: off, on, blink...StringLength=[8]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.4.1.1.3 |
mpduSmExtBarOutletRatingmandatory Sm Ext Bar Outlet's Rating in Amp. A value of -1 will be returned if the stick is unable to detect. StringLength=[8]. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.4 |
mpduSmExtBarOutletVoltagemandatory The SM Ext Bar voltage in volts. Value is presented 1/10 of the Volt i.e. 2098 means 209.8 V. A value of -1 will be returned if the voltage is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.5 |
mpduSmExtBarOutletCurrentmandatory The SM Ext Bar current draw in Amps. Value is presented in 1/100 of the Amperei.e. 127 means 1.27 A. A value of -1 will be returned if the current is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.6 |
mpduSmExtBarOutletPowerWattmandatory The Sm Ext Bar's Power measured in Watts. A value of -1 will be returned if the power is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.7 |
mpduSmExtBarOutletPowerFactormandatory The outlet's power factor in 0.01 unit. It is presented in 1/100 of the unit. i.e. 98 means 0.98. A value of -1 will be returned if the voltage is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.8 |
mpduSmExtBarOutletDeviceNamemandatory The Device (Blade/Server/Storage) Name that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[50]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.4.1.1.9 |
mpduSmExtBarOutletDeviceUUIDmandatory The Device (Blade/Server/Storage) UUID that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[37]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.4.1.1.10 |
mpduSmExtBarOutletDeviceProductmandatory The Device (Blade/Server/Storage) Model that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[40]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.4.1.1.11 |
mpduSmExtBarOutletDeviceIPmandatory The Device (Blade/Server/Storage) IP of iLO that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[16]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.4.1.1.12 |
mpduSmExtBarOutletAutoDiscoveredmandatory Boolean values of 0 or 1. 1 means this Sm Ext Bar Outlet is able to get information from a blade with smart power supply (auto discovery is enabled)... | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.13 |
mpduSmExtBarOutletDeviceMACmandatory The Device (Blade/Server/Storage) MAC address that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[18]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.4.1.1.14 |
mpduSmExtBarOutletDeviceSNmandatory The Device (Blade/Server/Storage) Serial Number that connects to this Sm Ext Bar Outlet. Null will be returned if not detected. StringLength=[21]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.5.4.1.1.15 |
mpduSmExtBarOutletDevicePSSlotNomandatory The Device (Blade/Server/Storage) Power Supply' Slot Number that connects to this Sm Ext Bar Outlet. A value of -1 will be returned if not detected. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.16 |
mpduSmExtBarOutletDeviceUPositionmandatory Device U start position. A value of -1 will be returned if not detected. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.17 |
mpduSmExtBarOutletDeviceUHeightmandatory Device U height. Enter -1 if not detected. Some device supports non-integer. Present value x100, when read back, divided by 100 to get 2 decimal points. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.18 |
| 0=Left 0U side area or rack frame, 1= Right 0U side area or rack frame, 2= front RETMA rail, 3=back RETMA rail) - spatial location. A value of -1 will be returned if not detected. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.19 |
mpduSmExtBarOutletPowerWattHourmandatory The Sm Ext Bar's Power measured in Watt-Hour support Billing Grade Energy Metering. A value of -1 will be returned if the power is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.5.4.1.1.20 |
.1.3.6.1.4.1.232.165.6.3.4
·
1 row entry
·
4 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk oupsInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::oupsInputTable'
Aggregate Object with number of entries equal to NumPhases and including the UpsInput group.
The input table entry containing the current, voltage, etc.
Indexes
| Column | Syntax | OID |
|---|---|---|
oupsInputPhasemandatory The number of the phase. Serves as index for input table. | Integer32 Constraints: range: 0-6 | .1.3.6.1.4.1.232.165.6.3.4.1.1 |
oupsInputVoltagemandatory The measured input voltage from the UPS meters in volts. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.6.3.4.1.2 |
oupsInputCurrentmandatory The measured input current from the UPS meters in amps. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.6.3.4.1.3 |
oupsInputWattsmandatory The measured input power in watts. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.6.3.4.1.4 |
.1.3.6.1.4.1.232.165.6.4.4
·
1 row entry
·
5 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk oupsOutputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::oupsOutputTable'
The Aggregate Object with number of entries equal to NumPhases and including the UpsOutput group.
Output Table Entry containing voltage, current, etc.
Indexes
| Column | Syntax | OID |
|---|---|---|
oupsOutputPhasemandatory The number {1..3} of the output phase. | Integer32 Constraints: range: 0-6 | .1.3.6.1.4.1.232.165.6.4.4.1.1 |
oupsOutputVoltagemandatory The measured output voltage from the UPS metering in volts. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.6.4.4.1.2 |
oupsOutputCurrentmandatory The measured UPS output current in amps. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.6.4.4.1.3 |
oupsOutputWattsmandatory The measured real output power in watts. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.6.4.4.1.4 |
oupsOutputLoadPerPhasemandatory The UPS output load per phase in percentage of rated capacity. | Integer32 Constraints: range: 0-200 | .1.3.6.1.4.1.232.165.6.4.4.1.5 |
.1.3.6.1.4.1.232.165.7.1.2
·
1 row entry
·
12 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2IdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2IdentTable'
Aggregate Object with number of entries equal to pdu2NumberPDU .
The ident table entry containing the name, model, manufacturer,
firmware version, part number, etc.
firmware version, part number, etc.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
pdu2IdentIndexmandatory Index for the Pdu2IdentEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.7.1.2.1.1 | ||||||||
pdu2Namemandatory The string identify the device in daisy chain. Example PDU A. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.1.2.1.2 | ||||||||
pdu2Modelmandatory The Device Model. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.1.2.1.3 | ||||||||
pdu2Manufacturermandatory The Device Manufacturer Name (e.g. Hewlett-Packard). | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.1.2.1.4 | ||||||||
pdu2FirmwareVersionmandatory The firmware revision level of the device. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.1.2.1.5 | ||||||||
pdu2PartNumbermandatory The device part number. Example AF400A. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.1.2.1.6 | ||||||||
pdu2SerialNumbermandatory The device serial number, 10- or 16-digit. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.1.2.1.7 | ||||||||
pdu2Statusmandatory The overall status of the device. A value of OK(2) indicates the device is operating normally.A value of degraded(3) indicates the device is operating with warning indicators. A value of failed(4) indicates the devic… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.1.2.1.8 | ||||||||
pdu2Controllablemandatory This object indicates whether or not the device is controllable. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.1.2.1.9 | ||||||||
pdu2InputPhaseCountmandatory The number of input phase on this pdu 1,2,3. | Integer32 Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.1.2.1.10 | ||||||||
pdu2GroupCountmandatory The number of groups (breakers) on this pdu. | Integer32 Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.1.2.1.11 | ||||||||
pdu2OutletCountmandatory The number of outlets in this PDU. | Integer32 Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.1.2.1.12 |
.1.3.6.1.4.1.232.165.7.2.1
·
1 row entry
·
9 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2InputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2InputTable'
Aggregate Object with number of entries equal to pdu2NumberPDU .
The ident table entry containing the VA, Watts, WH, etc.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
pdu2InputTypemandatory Type of input - single phase, split phase, three phase delta, or threephase wye. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.2.1.1.1 | ||||||||
pdu2InputFrequencymandatory The measured input frequency from the PDU meters in tenths of Hz. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.7.2.1.1.2 | ||||||||
pdu2InputFrequencyStatusmandatory Status of the measured input frequency relative to the nominal frequency and the admitted tolerance. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.2.1.1.3 | ||||||||
pdu2InputPowerVAmandatory A total input VA of all phases. Units are VA. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.1.1.4 | ||||||||
pdu2InputPowerWattsmandatory A total input Watts of all phases. Units are Watts. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.1.1.5 | ||||||||
pdu2InputPowerWattHourmandatory A total input Watt-Hour value for all phases. Units are WH. This value can be reset to 0 using GUI. In that case, the pdu2InputPowerWattHourTimer will be reset as well A negative value indicates that this object is … | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.1.1.6 | ||||||||
pdu2InputPowerWattHourTimermandatory A Timestamp of when the Total Input WH was last reset. | OctetString Constraints: range: 0-22 | .1.3.6.1.4.1.232.165.7.2.1.1.7 | ||||||||
pdu2InputPowerFactormandatory An input PF value. Units are in thousandths, for example a power factorof 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.1.1.8 | ||||||||
pdu2InputPowerVARmandatory An input VAR value. Units are VAR. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.1.1.9 |
.1.3.6.1.4.1.232.165.7.2.2
·
1 row entry
·
25 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2InputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2InputPhaseTable'
Aggregate Object with number of entries equal to number of PDUs (pdu2NumberPDU) and number of input phase (pdu2InputPhaseCount).
The input table entry containing the voltage, current, frequency, power for each phase.
Entries are given with number of pdu and number of input phase 1, 2, or 3.
Entries are given with number of pdu and number of input phase 1, 2, or 3.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu2InputPhaseIndexmandatory Index for the Pdu2InputEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.7.2.2.1.1 | ||||||||||||||
pdu2InputPhaseVoltageMeasTypemandatory Value indicates what input voltage is being measured in this table row - single phasevoltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.2.2.1.2 | ||||||||||||||
pdu2InputPhaseVoltagemandatory An input voltage measurement value. Units are millivolts. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.3 | ||||||||||||||
pdu2InputPhaseVoltageThStatusmandatory Status of the measured input voltage relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.2.2.1.4 | ||||||||||||||
pdu2InputPhaseVoltageThLowerWarningmandatory Lower warning threshold. Units are millivolts. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.7.2.2.1.5 | ||||||||||||||
pdu2InputPhaseVoltageThLowerCriticalmandatory Lower critical threshold. Units are millivolts. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.7.2.2.1.6 | ||||||||||||||
pdu2InputPhaseVoltageThUpperWarningmandatory Upper warning threshold. Units are millivolts. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.7.2.2.1.7 | ||||||||||||||
pdu2InputPhaseVoltageThUpperCriticalmandatory Upper critical threshold. Units are millivolts. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.7.2.2.1.8 | ||||||||||||||
pdu2InputPhaseCurrentMeasTypemandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,phase 2, or phase 3. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.2.2.1.9 | ||||||||||||||
pdu2InputPhaseCurrentRatingmandatory Rated current capacity of the input. A negative value indicates thatthe hardware current capacity is unknown. Units are milliamps. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.10 | ||||||||||||||
pdu2InputPhaseCurrentmandatory An input current measurement value. Units are milliamps. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.11 | ||||||||||||||
pdu2InputPhaseCurrentThStatusmandatory Status of the measured input current relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.2.2.1.12 | ||||||||||||||
pdu2InputPhaseCurrentThLowerWarningmandatory Lower warning threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.2.2.1.13 | ||||||||||||||
pdu2InputPhaseCurrentThLowerCriticalmandatory Lower critical threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.2.2.1.14 | ||||||||||||||
pdu2InputPhaseCurrentThUpperWarningmandatory Upper warning threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.2.2.1.15 | ||||||||||||||
pdu2InputPhaseCurrentThUpperCriticalmandatory Upper critical threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.2.2.1.16 | ||||||||||||||
pdu2InputPhaseCurrentCrestFactormandatory Current crest factor. Units are in milli, for example a crest factor of1.414 will be returned as 1414. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.17 | ||||||||||||||
pdu2InputPhaseCurrentPercentLoadmandatory Current percent load, based on the rated current capacity. Units arepercentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.18 | ||||||||||||||
pdu2InputPhasePowerMeasTypemandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,phase 2, or phase 3. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.2.2.1.19 | ||||||||||||||
pdu2InputPhasePowerVAmandatory An input VA value. Units are VA. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.20 | ||||||||||||||
pdu2InputPhasePowerWattsmandatory An input Watts value. Units are Watts. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.21 | ||||||||||||||
pdu2InputPhasePowerWattHourmandatory A Watt-Hour value for each Input phase. Units are WH. This value can be reset to 0 using GUI. In that case, the pdu2InputPhasePowerWattHourTimer will be reset as well A negative value indicates that this object is… | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.22 | ||||||||||||||
pdu2InputPhasePowerWattHourTimermandatory Timestamp of when input Watt-hours (inputWh) was last reset. | OctetString Constraints: range: 0-22 | .1.3.6.1.4.1.232.165.7.2.2.1.23 | ||||||||||||||
pdu2InputPhasePowerFactormandatory An input PF value. Units are in thousandths, for example a power factorof 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.24 | ||||||||||||||
pdu2InputPhasePowerVARmandatory An input VAR value. Units are VAR. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.2.2.1.25 |
.1.3.6.1.4.1.232.165.7.3.1
·
1 row entry
·
27 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2GroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2GroupTable'
Aggregate Object with number of entries equal to number of PDUs and number of breakers (pdu2GroupCount).
The input table entry containing the name, voltages, currents, power, etc.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu2GroupIndexmandatory Index for the Pdu2GroupEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.7.3.1.1.1 | ||||||||||||||
pdu2GroupNamemandatory A descriptive name for the group. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.7.3.1.1.2 | ||||||||||||||
pdu2GroupTypemandatory The type of the group. (5) has no breaker | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.3.1.1.3 | ||||||||||||||
pdu2GroupVoltageMeasTypemandatory Value indicates what input voltage is being measured in this table row - single phasevoltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.3.1.1.4 | ||||||||||||||
pdu2GroupVoltagemandatory Units are millivolts. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.5 | ||||||||||||||
pdu2GroupVoltageThStatusmandatory Status of the measured group voltage relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.3.1.1.6 | ||||||||||||||
pdu2GroupVoltageThLowerWarningmandatory Lower warning threshold. Units are millivolts. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.7.3.1.1.7 | ||||||||||||||
pdu2GroupVoltageThLowerCriticalmandatory Lower critical threshold. Units are millivolts. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.7.3.1.1.8 | ||||||||||||||
pdu2GroupVoltageThUpperWarningmandatory Upper warning threshold. Units are millivolts. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.7.3.1.1.9 | ||||||||||||||
pdu2GroupVoltageThUpperCriticalmandatory Upper critical threshold. Units are millivolts. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.7.3.1.1.10 | ||||||||||||||
pdu2groupCurrentRatingmandatory Rated current capacity of the group. Units are milliamps. A negative value indicates that the hardware current capacity is unknown (it will always be unknown for custom groups). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.11 | ||||||||||||||
pdu2GroupCurrentmandatory A group current measurement value. Units are milliamps. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.12 | ||||||||||||||
pdu2GroupCurrentThStatusmandatory Status of the measured group current relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.3.1.1.13 | ||||||||||||||
pdu2GroupCurrentThLowerWarningmandatory Lower warning threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.3.1.1.14 | ||||||||||||||
pdu2GroupCurrentThLowerCriticalmandatory Lower critical threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.3.1.1.15 | ||||||||||||||
pdu2GroupCurrentThUpperWarningmandatory Upper warning threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.3.1.1.16 | ||||||||||||||
pdu2GroupCurrentThUpperCriticalmandatory Upper critical threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.3.1.1.17 | ||||||||||||||
pdu2GroupCurrentCrestFactormandatory Current crest factor. Units are in milli, for example a crest factor of1.414 will be returned as 1414. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.18 | ||||||||||||||
pdu2GroupCurrentPercentLoadmandatory Current percent load, based on the rated current capacity. Units arepercentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.19 | ||||||||||||||
pdu2GroupPowerVAmandatory A group VA value. Units are VA. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.20 | ||||||||||||||
pdu2GroupPowerWattsmandatory A group Watts value. Units are Watts. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.21 | ||||||||||||||
pdu2GroupPowerWattHourmandatory A Watt-Hour value for each section. Units are WH. This value can be reset to 0 using GUI. In that case, the pdu2GroupPowerWattHourTimer will be reset as well. A negative value indicates that this object is not ava… | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.22 | ||||||||||||||
pdu2GroupPowerWattHourTimermandatory Timestamp of when group Watt-hours (groupWh) was last reset. | OctetString Constraints: range: 0-22 | .1.3.6.1.4.1.232.165.7.3.1.1.23 | ||||||||||||||
pdu2GroupPowerFactormandatory A group PF value. Units are in thousandths, for example a power factorof 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.24 | ||||||||||||||
pdu2GroupPowerVARmandatory A group VAR value. Units are VAR. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.3.1.1.25 | ||||||||||||||
pdu2GroupOutletCountmandatory The number of outlets in each group (breaker). | Integer32 Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.7.3.1.1.26 | ||||||||||||||
pdu2GroupBreakerStatusmandatory Only applicable to groups with breaker. Indicates whether a breaker is turnedoff or on. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.3.1.1.27 |
.1.3.6.1.4.1.232.165.7.4.1
·
1 row entry
·
4 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2EnvProbeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2EnvProbeTable'
A list of environment probe (1 per PDU) for temperature, humidity, and contacts. The number of entries is given by number of PDUs in daisy chain.
Aggregate entries equal to number of PDUs.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
pdu2TemperatureScalemandatory Scale used to return temperature objects. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.4.1.1.1 | ||||
pdu2TemperatureCountmandatory Max number of temperature measurements (1 per probe). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.4.1.1.2 | ||||
pdu2HumidityCountmandatory Max number of humidity measurements (1 per probe). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.4.1.1.3 | ||||
pdu2ContactCountmandatory Max number of contact sensors (1 per probe). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.4.1.1.4 |
.1.3.6.1.4.1.232.165.7.4.2
·
1 row entry
·
9 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2TemperatureTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2TemperatureTable'
A list of temperature probe measurements. The number of entries are given by number of pdu and pdu2TemperatureCount.
An entry for a temperature measurement.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu2TemperatureIndexmandatory A unique value for each temperature probe measurement. Its valueranges from 1 to temperatureCount. | Integer32 Constraints: range: 1-2 | .1.3.6.1.4.1.232.165.7.4.2.1.1 | ||||||||||
pdu2TemperatureNamemandatory A descriptive name for the temperature probe. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.7.4.2.1.2 | ||||||||||
pdu2TemperatureProbeStatusmandatory Indicates whether a probe is connected or not. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.4.2.1.3 | ||||||||||
pdu2TemperatureValuemandatory Units are in tenths of a degree (either Fahrenheit or Celsius). Divide by ten to get degrees. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.4.2.1.4 | ||||||||||
pdu2TemperatureThStatusmandatory Status of the measured temperature relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.4.2.1.5 | ||||||||||
pdu2TemperatureThLowerWarningmandatory Lower warning threshold. Units are tenths of a degree. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-150000 | .1.3.6.1.4.1.232.165.7.4.2.1.6 | ||||||||||
pdu2TemperatureThLowerCriticalmandatory Lower critical threshold. Units are tenths of a degree. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-150000 | .1.3.6.1.4.1.232.165.7.4.2.1.7 | ||||||||||
pdu2TemperatureThUpperWarningmandatory Upper warning threshold. Units are tenths of a degree. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-150000 | .1.3.6.1.4.1.232.165.7.4.2.1.8 | ||||||||||
pdu2TemperatureThUpperCriticalmandatory Upper critical threshold. Units are tenths of a degree. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-150000 | .1.3.6.1.4.1.232.165.7.4.2.1.9 |
.1.3.6.1.4.1.232.165.7.4.3
·
1 row entry
·
9 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2HumidityTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2HumidityTable'
A list of humidity probe measurements. The number of entries are given by number of pdu and pdu2HumidityCount.
An entry for a humidity measurement.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu2HumidityIndexmandatory A unique value for each humidity probe measurement. Its valueranges from 1 to pdu2HumidityCount per pdu. | Integer32 Constraints: range: 1-2 | .1.3.6.1.4.1.232.165.7.4.3.1.1 | ||||||||||
pdu2HumidityNamemandatory A descriptive name for the humidity probe. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.7.4.3.1.2 | ||||||||||
pdu2HumidityProbeStatusmandatory Indicates whether a probe is connected or not. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.4.3.1.3 | ||||||||||
pdu2HumidityValuemandatory Units are tenths of a percent relative humidity. Divide the value by 10 to get %RH. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.4.3.1.4 | ||||||||||
pdu2HumidityThStatusmandatory Status of the measured humidity relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.4.3.1.5 | ||||||||||
pdu2HumidityThLowerWarningmandatory Lower warning threshold. Units are 0.1 %RH. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-1000 | .1.3.6.1.4.1.232.165.7.4.3.1.6 | ||||||||||
pdu2HumidityThLowerCriticalmandatory Lower critical threshold. Units are 0.1 %RH. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-1000 | .1.3.6.1.4.1.232.165.7.4.3.1.7 | ||||||||||
pdu2HumidityThUpperWarningmandatory Upper warning threshold. Units are 0.1 %RH. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-1000 | .1.3.6.1.4.1.232.165.7.4.3.1.8 | ||||||||||
pdu2HumidityThUpperCriticalmandatory Upper critical threshold. Units are 0.1 %RH. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-1000 | .1.3.6.1.4.1.232.165.7.4.3.1.9 |
.1.3.6.1.4.1.232.165.7.4.4
·
1 row entry
·
4 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2ContactTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2ContactTable'
A list of contact sensors. The number of entries are given by number of pdu and pdu2ContactCount.
An entry for a contact sensor
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
pdu2ContactIndexmandatory A unique value for each contact sensor. Its value ranges from 1 tocontactCount. | Integer32 Constraints: range: 1-3 | .1.3.6.1.4.1.232.165.7.4.4.1.1 | ||||||
pdu2ContactNamemandatory A descriptive name for the contact sensor. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.7.4.4.1.2 | ||||||
pdu2ContactProbeStatusmandatory Indicates whether a probe is connected or not.Will not be returned if the contact sensor is internal to the ePDU, in that case only contactState should be read. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.4.4.1.3 | ||||||
pdu2ContactStatemandatory The state of the contact sensor. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.4.4.1.4 |
.1.3.6.1.4.1.232.165.7.5.1
·
1 row entry
·
18 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2OutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2OutletTable'
Aggregate Object with number of entries equal to Number of PDU (pdu2IdentIndex) and Number of outlet per PDU (pdu2OutletIndex).
The Outlet table entry containing the type, voltage, current etc.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu2OutletIndexmandatory Index for each outlet, value from 1 to the number of outlets per PDU. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.7.5.1.1.1 | ||||||||||||||||||||||||||||||||
pdu2OutletNamemandatory A descriptive name for the outlet. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.7.5.1.1.2 | ||||||||||||||||||||||||||||||||
pdu2OutletTypemandatory Type of this outlet - C13, C19. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.5.1.1.3 | ||||||||||||||||||||||||||||||||
pdu2OutletCurrentRatingmandatory Rated current capacity of this outlet. Units are milliamps. A negative value indicates that the hardware current capacity is unknown. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.5.1.1.4 | ||||||||||||||||||||||||||||||||
pdu2OutletCurrentmandatory A outlet current measurement value. Units are milliamps. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.5.1.1.5 | ||||||||||||||||||||||||||||||||
pdu2OutletCurrentThStatusmandatory Status of the measured outlet current relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.5.1.1.6 | ||||||||||||||||||||||||||||||||
pdu2OutletCurrentThLowerWarningmandatory Lower warning threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.5.1.1.7 | ||||||||||||||||||||||||||||||||
pdu2OutletCurrentThLowerCriticalmandatory Lower critical threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.5.1.1.8 | ||||||||||||||||||||||||||||||||
pdu2OutletCurrentThUpperWarningmandatory Upper warning threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.5.1.1.9 | ||||||||||||||||||||||||||||||||
pdu2OutletCurrentThUpperCriticalmandatory Upper critical threshold. Units are milliamps. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.7.5.1.1.10 | ||||||||||||||||||||||||||||||||
pdu2OutletCurrentCrestFactormandatory Current crest factor. Units are in milli, for example a crest factor of1.414 will be returned as 1414. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.5.1.1.11 | ||||||||||||||||||||||||||||||||
pdu2OutletCurrentPercentLoadmandatory Current percent load, based on the rated current capacity. Units arepercentage, for example 80% will be returned as 80. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.5.1.1.12 | ||||||||||||||||||||||||||||||||
pdu2OutletVAmandatory A outlet VA value. Units are VA. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.5.1.1.13 | ||||||||||||||||||||||||||||||||
pdu2OutletWattsmandatory A outlet Watts value. Units are Watts. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.5.1.1.14 | ||||||||||||||||||||||||||||||||
pdu2OutletWhmandatory A Watt-Hour value for each outlet. Units are WH.This object is writable so that it can be reset to 0. When it is written to, the pdu2OutletWhTimer will be reset updated as well A negative value indicates that thi… | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.5.1.1.15 | ||||||||||||||||||||||||||||||||
pdu2OutletWhTimermandatory Timestamp (date and time) of outlet Watt-hours was last reset. | OctetString Constraints: range: 0-22 | .1.3.6.1.4.1.232.165.7.5.1.1.16 | ||||||||||||||||||||||||||||||||
pdu2OutletPowerFactormandatory An outlet PF value. Units are in thousandths, for example a power factorof 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.5.1.1.17 | ||||||||||||||||||||||||||||||||
pdu2OutletVARmandatory An outlet VAR value. Units are VAR. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.7.5.1.1.18 |
.1.3.6.1.4.1.232.165.7.5.2
·
1 row entry
·
9 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu2OutletControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu2OutletControlTable'
Aggregate Object with number of entries equal to Number of PDU (pdu2IdentIndex) and Number of outlets per PDU (pdu2OutletIndex).
The Outlet table entry containing the type, voltage, current etc.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
pdu2OutletControlStatusmandatory current state of a control outlet. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.7.5.2.1.1 | ||||||||
pdu2OutletControlOffCmdmandatory When write, once issued, the outlet will turn Off immediately.0-n: Time in seconds until the outlet command is issued -1: Cancel a pending outlet Off command When read, returns -1 if no command is pending, or the curr… | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.7.5.2.1.2 | ||||||||
pdu2OutletControlOnCmdmandatory When write, once issued, the outlet will turn On immediately.0-n: Time in seconds until the outlet command is issued -1: Cancel a pending outlet On command When read, returns -1 if no command is pending, or the curren… | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.7.5.2.1.3 | ||||||||
pdu2OutletControlRebootCmdmandatory When write, for outlets that are On prior to this Reboot command, they will switch Off immediately when the command is issued, remain Off for outletControlRebootOffTime seconds, and then turn back On. For outlets tha… | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.7.5.2.1.4 | ||||||||
pdu2OutletControlPowerOnStatemandatory Determines the outlet state when power is applied to the unit.1 : not restart at device startup 2 : should sequence back ON in line with outletControlSequenceTime 3 : should take the state the outlet had when power was… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.7.5.2.1.5 | ||||||||
pdu2OutletControlSequenceDelaymandatory Time delay in seconds from when a Global Sequence On command is issued towhen the command is executed on this outlet. This delay is also used as a power-on delay. Set to -1 to exclude this outlet from Global Sequence … | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.7.5.2.1.6 | ||||||||
pdu2OutletControlRebootOffTimemandatory Time delay in seconds that the outlet should remain in the Off state when executing a Reboot command. | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.7.5.2.1.7 | ||||||||
pdu2OutletControlSwitchablemandatory Determines the outlet capability to be controlled On/Off from the communication channels.1 : control On/Off enabled 2 : control On/Off disabled. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.7.5.2.1.8 | ||||||||
pdu2OutletControlShutoffDelaymandatory Time delay in seconds that could be taken in account before shutting of the outlet.An application which need to shutoff properly an outlet will read this parameter first then write it to the command pdu2OutletControlOf… | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.7.5.2.1.9 |
.1.3.6.1.4.1.232.165.9.1.2
·
1 row entry
·
17 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk hpduIdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::hpduIdentTable'
Indexed by 1 Hpdu unit.
The table entry containing the identifications of HPDU
Indexes
| Column | Syntax | OID |
|---|---|---|
hpduIdentIndexmandatory Index for the MpduIdentEntry table. Start with 1 | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.9.1.2.1.1 |
hpduManufacturermandatory The Core PDU manufacturer. StringLength=[21] | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.2 |
hpduModelmandatory The Core PDU model, marketing name. StringLength=[40]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.3 |
hpduNamemandatory The Core PDU name, descriptive name or hostname. StringLength=[16]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.4 |
hpduFirmwareVersionmandatory The Core PDU firmware version(s). StringLength=[12]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.5 |
hpduHardwareVersionmandatory The Core PDU hardware version. StringLength=[8]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.6 |
hpduPartNumbermandatory The Core PDU part number. StringLength=[21]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.7 |
hpduSerialNumbermandatory The PDU external serial number. StringLength=[21]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.8 |
hpduUUIDmandatory The PDU's UUID equals PN add SN, canonical conversion. StringLength=[37]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.9 |
hpduTypemandatory The PDU's Type: Delta, Wye, single, Wye+lowline.StringLength=[24]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.10 |
hpduPowerRatingmandatory The PDU's Power Rating in KVA (Name Plate). Value is presented in 1/100 of the KVA. i.e. 1750 means 17.50 KVA | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.11 |
hpduInputRatingmandatory The PDU's Input Current Rating in A (Name Plate) | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.12 |
hpduRegionalNominalVoltagemandatory value is either America(208V), Japan(202V) or blank for International Model | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.13 |
hpduNumOutputBreakersmandatory The number of outlets with breakers of each hpdu. | Integer32 Constraints: range: 0-10 | .1.3.6.1.4.1.232.165.9.1.2.1.14 |
hpduNumMonitoredOutletmandatory The number of measured outlets (with CT, VT) of each hpdu. | Integer32 Constraints: range: 0-10 | .1.3.6.1.4.1.232.165.9.1.2.1.15 |
hpduFanStatusmandatory Report fan status: OK or FAIL | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.1.2.1.16 |
hpduTemperaturemandatory The internal temperature in Celcius. Value is presented in 1/10 of a degree i.e. 251 is 25.1. A value of -1 will be returned if the temperature is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.1.2.1.17 |
.1.3.6.1.4.1.232.165.9.2.1
·
1 row entry
·
13 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk hpduInputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::hpduInputTable'
Indexed by hpduNumPhase.
The Input table entry containing the voltage, current, PF,
percent load, VA, Watts for the HPDU.
percent load, VA, Watts for the HPDU.
Indexes
| Column | Syntax | OID |
|---|---|---|
hpduInputIndexmandatory Index for the hpduInputEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.9.2.1.1.1 |
hpduInputStatusmandatory The overall status of the Input: off, on, problem. StringLength=[7]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.2.1.1.2 |
hpduInputBreakerRatingmandatory The rating of each hpdu Input in Ampere. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.3 |
hpduInputVoltagemandatory The measured Input voltage from the PDU meters in volts. Value is presented in 1/10 of the Volt i.e. 2095 is 209.5 V. A value of -1 will be returned if the voltage is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.4 |
hpduInputCurrentmandatory The measured Input current from the PDU meters in amps. Value is presented in 1/100 of the Ampere i.e. 175 is 1.75 A. A value of -1 will be returned if the current is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.5 |
hpduInputPowerVAmandatory The total Input Power measured in VA. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.6 |
hpduInputPowerWattmandatory The total Input power measured in Watts. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.7 |
hpduInputPowerFactormandatory The Input power factor is presented in 1/100 of the unit i.e.98 is 0.98. A value of -1 will be returned if the power factor is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.8 |
hpduInputWarningThresholdmandatory Report the User-setting Input threshhold limit for Warning in percentage | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.9 |
hpduInputCriticalThresholdmandatory Report the User-setting Input threshhold limit for Critical in percentage | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.10 |
hpduInputPowerWattHourmandatory Support Billing Grade Energy Metering in Watt-Hour. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.11 |
hpduInputTotalEnergySincemandatory Display the date and time that starts to accumulate the per Load segment energy in WH. Date and Time can be set by user on GUI. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.2.1.1.12 |
hpduInputEnergyMeteringTotalHoursmandatory Total hours of collecting measurement data. A value of -1 will be returned if the value is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.2.1.1.13 |
.1.3.6.1.4.1.232.165.9.3.1
·
1 row entry
·
14 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk hpduOutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::hpduOutletTable'
Indexed by hpduNumMonitoredOutlet and hpduNumPhase . So aggregate objects for each entry equal to (hpduNumMonitoredOutlet x hpduNumPhase). Start with 1.
The Outlet table entry containing the voltage, current, PF,
percent load, VA, Watts for the Modular PDU.
percent load, VA, Watts for the Modular PDU.
| Column | Syntax | OID |
|---|---|---|
hpduOutletIndexmandatory Index for the hpduOutletEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.9.3.1.1.1 |
hpduOutletStatusmandatory The overall status of the breaker: off, on, problem. StringLength=[7]. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.3.1.1.2 |
hpduOutletBreakerRatingmandatory The rating of each hpdu Outlet in Ampere. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.3 |
hpduOutletPercentLoadmandatory The hpdu's each Outlet load in percent of rated capacity. Value is presented in 1/10 of the percentage i.e. 125 is 12.5%. A value of -1 will be returned if the current is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.4 |
hpduOutletVoltagemandatory The measured Outlet voltage from the PDU meters in volts. Value is presented in 1/10 of the Volt i.e. 2095 is 209.5 V. A value of -1 will be returned if the voltage is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.5 |
hpduOutletCurrentmandatory The measured Outlet current from the PDU meters in amps. Value is presented in 1/100 of the Ampere i.e. 175 is 1.75 A. A value of -1 will be returned if the current is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.6 |
hpduOutletPowerVAmandatory The total VA load (VI) measured on the PDU in VA. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.7 |
hpduOutletPowerWattmandatory The total power load measured on the PDU in Watts. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.8 |
hpduOutletPowerFactormandatory The power factor is presented in 1/100 of the unit i.e.98 is 0.98. A value of -1 will be returned if the power factor is unable to be measured. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.9 |
hpduOutletWarningThresholdmandatory Report the User-set threshhold limit for Warning in percentage | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.10 |
hpduOutletCriticalThresholdmandatory Report the User-set threshhold limit for Critical in percentage | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.11 |
hpduOutletPowerWattHourmandatory Support Billing Grade Energy Metering in Watt-Hour. A value of -1 will be returned if the power is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.12 |
hpduOutletTotalEnergySincemandatory Display the date and time that starts to accumulate the per Load segment energy in WH. Date and Time can be set by user on GUI. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.9.3.1.1.13 |
hpduOutletEnergyMeteringTotalHoursmandatory Total hours of collecting measurement data. A value of -1 will be returned if the value is unable to be calculated. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.9.3.1.1.14 |
.1.3.6.1.4.1.232.165.11.1.2
·
1 row entry
·
16 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3IdentTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3IdentTable'
Aggregate Object with number of entries equal to pdu3NumberPDU .
The ident table entry containing the name, model, manufacturer,
firmware version, part number, etc.
firmware version, part number, etc.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
pdu3IdentIndexmandatory Index for the Pdu3IdentEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.11.1.2.1.1 | ||||||||
pdu3Namemandatory The string identify the device in daisy chain. Example PDU A. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.1.2.1.2 | ||||||||
pdu3Modelmandatory The Device Model. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.1.2.1.3 | ||||||||
pdu3Manufacturermandatory The Device Manufacturer Name (e.g. Hewlett-Packard). | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.1.2.1.4 | ||||||||
pdu3FirmwareVersionmandatory The firmware revision level of the device. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.1.2.1.5 | ||||||||
pdu3FirmwareVersionTimeStampmandatory Timestamp of when the PDU firmware was last updated | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.11.1.2.1.6 | ||||||||
pdu3PartNumbermandatory The device part number. Example AF400A. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.1.2.1.7 | ||||||||
pdu3SerialNumbermandatory The device serial number, 10- or 16-digit. | OctetString Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.1.2.1.8 | ||||||||
pdu3Statusmandatory The overall status of the device. A value of OK(2) indicates the device is operating normally.A value of degraded(3) indicates the device is operating with warning indicators. A value of failed(4) indicates the devic… | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.2.1.9 | ||||||||
pdu3Controllablemandatory This object indicates whether or not the device is controllable. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.2.1.10 | ||||||||
pdu3InputPhaseCountmandatory The number of input phase on this pdu 1,2,3. | Integer32 Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.1.2.1.11 | ||||||||
pdu3GroupCountmandatory The number of groups (breakers) on this pdu. | Integer32 Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.1.2.1.12 | ||||||||
pdu3OutletCountmandatory The number of outlets in this PDU. | Integer32 Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.1.2.1.13 | ||||||||
pdu3MACAddressmandatory The assigned MAC address for this PDU. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.11.1.2.1.14 | ||||||||
pdu3IPv4Addressmandatory The current IPv4 Address. A value of 0.0.0.0 indicates an error or an unset option. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.11.1.2.1.15 | ||||||||
pdu3IPv6Addressmandatory The current IPv6 Address.A vale of 0.0.0.0.0.0 indicates an error or an unset option. | RFC1213-MIBDisplayString | .1.3.6.1.4.1.232.165.11.1.2.1.16 |
.1.3.6.1.4.1.232.165.11.1.3
·
1 row entry
·
11 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3ConfigTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3ConfigTable'
Aggregate Object with number of entries equal to pdu3NumberPDU .
Read Configuration data from the PDU being queried.
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
pdu3ConfigIndexmandatory The index of PDU configuration entry. | Integer32 Constraints: range: 0-20 | .1.3.6.1.4.1.232.165.11.1.3.1.1 | ||||||
pdu3ConfigSshmandatory Setting this OID to off(0) will disable the SSH conneciton.Setting this OID to on(1) will enable the SSH connection. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.2 | ||||||
pdu3ConfigFtpsmandatory Setting this OID to off(0) will disable the FTPS connection.Setting this OID to on(1) will enable the FTPS connection. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.3 | ||||||
pdu3ConfigHttpmandatory Setting this OID to off(0) will disable the HTTP connection.Setting this OID to on(1) will enable the HTTP connection. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.4 | ||||||
pdu3ConfigHttpsmandatory Setting this OID to off(0) will disable the HTTPS connection.Setting this OID to on(1) will enable the HTTPS connection. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.5 | ||||||
pdu3ConfigIPv4IPv6Switchmandatory Setting this OID to IPv4(1) will enable the IPv4 configuration.Setting this OID to IPv6(2) will enable the IPv6 configuration. Setting this OID to IPv4&IPv6(3) will enable both IPv4 and IPv6 configuration. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.6 | ||||||
pdu3ConfigRedfishAPImandatory Setting this OID to off(0) will disable the Redfish API.Setting this OID to on(1) will enable the Redfish API. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.7 | ||||||
pdu3ConfigOledDispalyOrientationmandatory Indicates the intended physical orientation of OLED display.displayNormal(1) indicates normal orientation. displayReverse(2) indicates upside down orientation. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.8 | ||||||
pdu3ConfigEnergyResetmandatory Setting this OID to reset(2) will cause the device energy meter value to be reset to zero. Getting this OID in models that support this feature will do nothing and return the noOperation(1) value. Models that do not su… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.9 | ||||||
pdu3ConfigNetworkManagementCardResetmandatory Getting this OID will return noOperation(0).Getting this OID to reset(1) will reset NMC. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.10 | ||||||
pdu3ConfigDaisyChainStatusmandatory Setting this OID to daisychain(0) will enable daisychain mode. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.11.1.3.1.11 |
.1.3.6.1.4.1.232.165.11.2.1
·
1 row entry
·
10 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3InputTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3InputTable'
Aggregate Object with number of entries equal to pdu3NumberPDU .
The ident table entry containing the VA, Watts, WH, etc.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
pdu3InputTypemandatory Type of input - single phase, split phase, three phase delta, or threephase wye. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.2.1.1.1 | ||||||||
pdu3InputFrequencymandatory The measured input frequency from the PDU meters in tenths of Hz. | Integer32 Constraints: range: 0-2147483647 | .1.3.6.1.4.1.232.165.11.2.1.1.2 | ||||||||
pdu3InputFrequencyStatusmandatory Status of the measured input frequency relative to the nominal frequency and the admitted tolerance. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.2.1.1.3 | ||||||||
pdu3InputPowerVAmandatory A total input VA of all phases. Units are 0.001 VA. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.1.1.4 | ||||||||
pdu3InputPowerWattsmandatory A total input Watts of all phases. Units are 0.001 Watts. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.1.1.5 | ||||||||
pdu3InputTotalEnergymandatory A total input Watt-Hour value for all phases. Units are KWh. This value is accumulated since PDU in service. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.1.1.6 | ||||||||
pdu3InputPowerWattHourTimermandatory A Timestamp of when the Total Input WH was last reset. | OctetString Constraints: range: 0-22 | .1.3.6.1.4.1.232.165.11.2.1.1.7 | ||||||||
pdu3InputResettableEnergymandatory A total input Watt-Hour value for all phases. Units are 0.001 Wh. This value can be reset to 0 using GUI. In that case, the pdu3InputPowerWattHourTimer will be reset as well A negative value indicates that this obje… | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.1.1.8 | ||||||||
pdu3InputPowerFactormandatory An input PF value. Units are in thousandths, for example a power factorof 0.958 would be returned as 958, and 0.92 would be returned as 920. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.1.1.9 | ||||||||
pdu3InputPowerVARmandatory An input VAR value. Units are 0.001 VAR. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.1.1.10 |
.1.3.6.1.4.1.232.165.11.2.2
·
1 row entry
·
24 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3InputPhaseTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3InputPhaseTable'
Aggregate Object with number of entries equal to number of PDUs (pdu3NumberPDU) and number of input phase (pdu3InputPhaseCount).
The input table entry containing the voltage, current, frequency, power for each phase.
Entries are given with number of pdu and number of input phase 1, 2, or 3.
Entries are given with number of pdu and number of input phase 1, 2, or 3.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu3InputPhaseIndexmandatory Index for the Pdu3InputEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.11.2.2.1.1 | ||||||||||||||
pdu3InputPhaseVoltageMeasTypemandatory Value indicates what input voltage is being measured in this table row - single phasevoltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.2.2.1.2 | ||||||||||||||
pdu3InputPhaseVoltagemandatory An input voltage measurement value. Return value is divided by 10. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.2.1.3 | ||||||||||||||
pdu3InputPhaseVoltageThStatusmandatory Status of the measured input voltage relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.2.2.1.4 | ||||||||||||||
pdu3InputPhaseVoltageThLowerWarningmandatory Lower warning threshold. Return value is divided by 10. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.11.2.2.1.5 | ||||||||||||||
pdu3InputPhaseVoltageThLowerCriticalmandatory Lower critical threshold. Return value is divided by 10. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.11.2.2.1.6 | ||||||||||||||
pdu3InputPhaseVoltageThUpperWarningmandatory Upper warning threshold. Return value is divided by 10. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.11.2.2.1.7 | ||||||||||||||
pdu3InputPhaseVoltageThUpperCriticalmandatory Upper critical threshold. Return value is divided by 10. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.11.2.2.1.8 | ||||||||||||||
pdu3InputPhaseCurrentMeasTypemandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,phase 2, or phase 3. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.2.2.1.9 | ||||||||||||||
pdu3InputPhaseCurrentRatingmandatory Rated current capacity of the input. A negative value indicates thatthe hardware current capacity is unknown. Return value is divided by 100. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.2.1.10 | ||||||||||||||
pdu3InputPhaseCurrentmandatory An input current measurement value. Return value is divided by 100. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.2.1.11 | ||||||||||||||
pdu3InputPhaseCurrentThStatusmandatory Status of the measured input current relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.2.2.1.12 | ||||||||||||||
pdu3InputPhaseCurrentThLowerWarningmandatory Lower warning threshold. Return value is divided by 100. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.11.2.2.1.13 | ||||||||||||||
pdu3InputPhaseCurrentThLowerCriticalmandatory Lower critical threshold. Return value is divided by 100. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.11.2.2.1.14 | ||||||||||||||
pdu3InputPhaseCurrentThUpperWarningmandatory Upper warning threshold. Return value is divided by 100. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.11.2.2.1.15 | ||||||||||||||
pdu3InputPhaseCurrentThUpperCriticalmandatory Upper critical threshold. Return value is divided by 100. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.11.2.2.1.16 | ||||||||||||||
pdu3InputPhaseCurrentPercentLoadmandatory Current percent load, based on the rated current capacity. Units arepercentage, for example 80.9 % will be returned as 809. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.2.1.17 | ||||||||||||||
pdu3InputPhasePowerMeasTypemandatory Which input wire is being measured in this table row - single phase, neutral, phase 1,phase 2, or phase 3. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.2.2.1.18 | ||||||||||||||
pdu3InputPhasePowerVAmandatory An input VA value. Units are VA. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.2.1.19 | ||||||||||||||
pdu3InputPhasePowerWattsmandatory An input Watts value. Units are Watts. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.2.1.20 | ||||||||||||||
pdu3InputPhasePowerWattHourmandatory A kWatt-Hour value for each Input phase. Units are kWh. This value can be reset to 0 using GUI. In that case, the pdu3InputPhasePowerWattHourTimer will be reset as well A negative value indicates that this object … | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.2.1.21 | ||||||||||||||
pdu3InputPhasePowerWattHourTimermandatory Timestamp of when input phase kWatt-hours (kWh) was last reset. | OctetString Constraints: range: 0-22 | .1.3.6.1.4.1.232.165.11.2.2.1.22 | ||||||||||||||
pdu3InputPhasePowerFactormandatory An input PF value. Return value is divided by 100, for example a power factorof 0.95 would be returned as 95. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.2.1.23 | ||||||||||||||
pdu3InputPhasePowerVARmandatory An input VA Reactive value. Units are in VAR. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.2.2.1.24 |
.1.3.6.1.4.1.232.165.11.3.1
·
1 row entry
·
26 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3GroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3GroupTable'
Aggregate Object with number of entries equal to number of PDUs and number of breakers (pdu3GroupCount).
The input table entry containing the name, voltages, currents, power, etc.
Indexes
| Column | Syntax | OID | ||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu3GroupIndexmandatory Index for the Pdu3GroupEntry table. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.11.3.1.1.1 | ||||||||||||||
pdu3GroupNamemandatory A descriptive name for the group. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.11.3.1.1.2 | ||||||||||||||
pdu3GroupTypemandatory The type of the group. (5) has no breaker | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.3.1.1.3 | ||||||||||||||
pdu3GroupVoltageMeasTypemandatory Value indicates what input voltage is being measured in this table row - single phasevoltage, phase 1 to neutral, phase 2 to neutral, phase 3 to neutral, phase 1 to phase 2, phase 2 to phase 3, or phase 3 to phase 1. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.3.1.1.4 | ||||||||||||||
pdu3GroupVoltagemandatory Return value is divided by 10 to get one decimal point, unit is in Volt. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.3.1.1.5 | ||||||||||||||
pdu3GroupVoltageThStatusmandatory Status of the measured group voltage relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.3.1.1.6 | ||||||||||||||
pdu3GroupVoltageThLowerWarningmandatory Lower warning threshold. Return value is divided by 10 to get one decimal point, unit is in Volt. A negative value indicates that this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.11.3.1.1.7 | ||||||||||||||
pdu3GroupVoltageThLowerCriticalmandatory Lower critical threshold. Return value is divided by 10 to get one decimal point, unit is in Volt. A negative value indicates that this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.11.3.1.1.8 | ||||||||||||||
pdu3GroupVoltageThUpperWarningmandatory Upper warning threshold. Return value is divided by 10 to get one decimal point, unit is in Volt. A negative value indicates that this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.11.3.1.1.9 | ||||||||||||||
pdu3GroupVoltageThUpperCriticalmandatory Upper critical threshold. Return value is divided by 10 to get one decimal point, unit is in Volt. A negative value indicates that this object is not available. | Integer32 Constraints: range: -1-500000 | .1.3.6.1.4.1.232.165.11.3.1.1.10 | ||||||||||||||
pdu3groupCurrentRatingmandatory Rated current capacity of the group. Return value is divided by 100 to get two decimal points, unit is in Amps. A negative value indicates that the hardware current capacity is unknown (it will always be unknown for… | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.3.1.1.11 | ||||||||||||||
pdu3GroupCurrentmandatory A group current measurement value. Return value is divided by 100 to get two decimal points. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.3.1.1.12 | ||||||||||||||
pdu3GroupCurrentThStatusmandatory Status of the measured group current relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.3.1.1.13 | ||||||||||||||
pdu3GroupCurrentThLowerWarningmandatory Lower warning threshold. Return value is divided by 100 to get two decimal points. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.11.3.1.1.14 | ||||||||||||||
pdu3GroupCurrentThLowerCriticalmandatory Lower critical threshold. Return value is divided by 100 to get two decimal points. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.11.3.1.1.15 | ||||||||||||||
pdu3GroupCurrentThUpperWarningmandatory Upper warning threshold. Return value is divided by 100 to get two decimal points. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.11.3.1.1.16 | ||||||||||||||
pdu3GroupCurrentThUpperCriticalmandatory Upper critical threshold. Return value is divided by 100 to get two decimal points. A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-100000 | .1.3.6.1.4.1.232.165.11.3.1.1.17 | ||||||||||||||
pdu3GroupCurrentPercentLoadmandatory Current percent load, based on the rated current capacity. Units arepercentage, for example 80.9 % will be returned as 809. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.3.1.1.18 | ||||||||||||||
pdu3GroupPowerVAmandatory A group VA value. Units are VA. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.3.1.1.19 | ||||||||||||||
pdu3GroupPowerWattsmandatory A group power value. Units are Watts. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.3.1.1.20 | ||||||||||||||
pdu3GroupPowerWattHourmandatory An energy consumption value for each load segment. Units are kWh. This value can be reset to 0 using GUI. In that case, the pdu3GroupPowerWattHourTimer will be reset as well. A negative value indicates that this o… | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.3.1.1.21 | ||||||||||||||
pdu3GroupPowerWattHourTimermandatory Timestamp when group kilo Watt-hours (group kWh) is reset. | OctetString Constraints: range: 0-22 | .1.3.6.1.4.1.232.165.11.3.1.1.22 | ||||||||||||||
pdu3GroupPowerFactormandatory A group PF value. Return value is divided by 100, for example a power factor of 0.95 would be returned as 95. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.3.1.1.23 | ||||||||||||||
pdu3GroupPowerVARmandatory A measurement for group/load segment power reactive. Units are VAR. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.3.1.1.24 | ||||||||||||||
pdu3GroupOutletCountmandatory The number of outlets in each group (breaker). | Integer32 Constraints: range: 0-63 | .1.3.6.1.4.1.232.165.11.3.1.1.25 | ||||||||||||||
pdu3GroupBreakerStatusmandatory Only applicable to groups with breaker. Indicates whether a breaker is turnedoff or on. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.3.1.1.26 |
.1.3.6.1.4.1.232.165.11.4.1
·
1 row entry
·
4 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3EnvProbeTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3EnvProbeTable'
A list of environment probe (1 per PDU) for temperature, humidity, and contacts. The number of entries is given by number of PDUs in daisy chain.
Aggregate entries equal to number of PDUs.
Indexes
| Column | Syntax | OID | ||||
|---|---|---|---|---|---|---|
pdu3TemperatureScalemandatory Scale used to return temperature objects. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.4.1.1.1 | ||||
pdu3TemperatureCountmandatory Max number of temperature measurements (1 per probe). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.4.1.1.2 | ||||
pdu3HumidityCountmandatory Max number of humidity measurements (1 per probe). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.4.1.1.3 | ||||
pdu3ContactCountmandatory Max number of contact sensors (1 per probe). | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.4.1.1.4 |
.1.3.6.1.4.1.232.165.11.4.2
·
1 row entry
·
9 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3TemperatureTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3TemperatureTable'
A list of temperature probe measurements. The number of entries are given by number of pdu and pdu3TemperatureCount.
An entry for a temperature measurement.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu3TemperatureIndexmandatory A unique value for each temperature probe measurement. Its valueranges from 1 to temperatureCount. | Integer32 Constraints: range: 1-2 | .1.3.6.1.4.1.232.165.11.4.2.1.1 | ||||||||||
pdu3TemperatureNamemandatory A descriptive name for the temperature probe. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.11.4.2.1.2 | ||||||||||
pdu3TemperatureProbeStatusmandatory Indicates whether a probe is connected or not. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.4.2.1.3 | ||||||||||
pdu3TemperatureValuemandatory Units are in tenths of a degree (either Fahrenheit or Celsius). Return value is divided by 10 to get degrees. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.4.2.1.4 | ||||||||||
pdu3TemperatureThStatusmandatory Status of the measured temperature relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.4.2.1.5 | ||||||||||
pdu3TemperatureThLowerWarningmandatory Lower warning threshold. Return value is divided by 10 to get degree. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-150000 | .1.3.6.1.4.1.232.165.11.4.2.1.6 | ||||||||||
pdu3TemperatureThLowerCriticalmandatory Lower critical threshold. Return value is divided by 10 to get degree. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-150000 | .1.3.6.1.4.1.232.165.11.4.2.1.7 | ||||||||||
pdu3TemperatureThUpperWarningmandatory Upper warning threshold. Return value is divided by 10 to get degree. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-150000 | .1.3.6.1.4.1.232.165.11.4.2.1.8 | ||||||||||
pdu3TemperatureThUpperCriticalmandatory Upper critical threshold. Return value is divided by 10 to get degree. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-150000 | .1.3.6.1.4.1.232.165.11.4.2.1.9 |
.1.3.6.1.4.1.232.165.11.4.3
·
1 row entry
·
9 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3HumidityTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3HumidityTable'
A list of humidity probe measurements. The number of entries are given by number of pdu and pdu3HumidityCount.
An entry for a humidity measurement.
Indexes
| Column | Syntax | OID | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu3HumidityIndexmandatory A unique value for each humidity probe measurement. Its valueranges from 1 to pdu3HumidityCount per pdu. | Integer32 Constraints: range: 1-2 | .1.3.6.1.4.1.232.165.11.4.3.1.1 | ||||||||||
pdu3HumidityNamemandatory A descriptive name for the humidity probe. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.11.4.3.1.2 | ||||||||||
pdu3HumidityProbeStatusmandatory Indicates whether a probe is connected or not. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.4.3.1.3 | ||||||||||
pdu3HumidityValuemandatory Units are tenths of a percent relative humidity. Return value is divided by 10 to get %RH. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.4.3.1.4 | ||||||||||
pdu3HumidityThStatusmandatory Status of the measured humidity relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.4.3.1.5 | ||||||||||
pdu3HumidityThLowerWarningmandatory Lower warning threshold. Return value is divided by 10 to get %RH. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-1000 | .1.3.6.1.4.1.232.165.11.4.3.1.6 | ||||||||||
pdu3HumidityThLowerCriticalmandatory Lower critical threshold. Return value is divided by 10 to get %RH. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-1000 | .1.3.6.1.4.1.232.165.11.4.3.1.7 | ||||||||||
pdu3HumidityThUpperWarningmandatory Upper warning threshold. Return value is divided by 10 to get %RH. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-1000 | .1.3.6.1.4.1.232.165.11.4.3.1.8 | ||||||||||
pdu3HumidityThUpperCriticalmandatory Upper critical threshold. Return value is divided by 10 to get %RH. A negative valueindicates that this object is not available. | Integer32 Constraints: range: -1-1000 | .1.3.6.1.4.1.232.165.11.4.3.1.9 |
.1.3.6.1.4.1.232.165.11.4.4
·
1 row entry
·
4 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3ContactTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3ContactTable'
A list of contact sensors. The number of entries are given by number of pdu and pdu3ContactCount.
An entry for a contact sensor
Indexes
| Column | Syntax | OID | ||||||
|---|---|---|---|---|---|---|---|---|
pdu3ContactIndexmandatory A unique value for each contact sensor. Its value ranges from 1 tocontactCount. | Integer32 Constraints: range: 1-3 | .1.3.6.1.4.1.232.165.11.4.4.1.1 | ||||||
pdu3ContactNamemandatory A descriptive name for the contact sensor. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.11.4.4.1.2 | ||||||
pdu3ContactProbeStatusmandatory Indicates whether a probe is connected or not.Will not be returned if the contact sensor is internal to the ePDU, in that case only contactState should be read. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.4.4.1.3 | ||||||
pdu3ContactStatemandatory The state of the contact sensor. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.4.4.1.4 |
.1.3.6.1.4.1.232.165.11.5.1
·
1 row entry
·
17 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3OutletTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3OutletTable'
Aggregate Object with number of entries equal to Number of PDU (pdu3IdentIndex) and Number of outlet per PDU (pdu3OutletIndex).
The Outlet table entry containing the type, voltage, current etc.
Indexes
| Column | Syntax | OID | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
pdu3OutletIndexmandatory Index for each outlet, value from 1 to the number of outlets per PDU. | Integer32 Constraints: range: 0-100 | .1.3.6.1.4.1.232.165.11.5.1.1.1 | ||||||||||||||||||||||||||||||||
pdu3OutletNamemandatory A descriptive name for the outlet. | OctetString Constraints: range: 1-31 | .1.3.6.1.4.1.232.165.11.5.1.1.2 | ||||||||||||||||||||||||||||||||
pdu3OutletTypemandatory Type of this outlet - C13, C19. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.5.1.1.3 | ||||||||||||||||||||||||||||||||
pdu3OutletCurrentRatingmandatory Rated current capacity of this outlet. Return value is divided by 100 to get amps. A negative value indicates that the hardware current capacity is unknown. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.5.1.1.4 | ||||||||||||||||||||||||||||||||
pdu3OutletCurrentmandatory A outlet current measurement value. Return value is divided by 100 to get amps. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.5.1.1.5 | ||||||||||||||||||||||||||||||||
pdu3OutletActivePowerThStatusmandatory Status of the measured outlet active power relative to the configured thresholds. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.5.1.1.6 | ||||||||||||||||||||||||||||||||
pdu3OutletActivePowerThLowerWarningmandatory Lower warning threshold. Units are Watts(W). A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-10000 | .1.3.6.1.4.1.232.165.11.5.1.1.7 | ||||||||||||||||||||||||||||||||
pdu3OutletActivePowerThLowerCriticalmandatory Lower critical threshold. Units are Watts(W). A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-10000 | .1.3.6.1.4.1.232.165.11.5.1.1.8 | ||||||||||||||||||||||||||||||||
pdu3OutletActivePowerThUpperWarningmandatory Upper warning threshold. Units are Watts(W). A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-10000 | .1.3.6.1.4.1.232.165.11.5.1.1.9 | ||||||||||||||||||||||||||||||||
pdu3OutletActivePowerThUpperCriticalmandatory Upper critical threshold. Units are Watts(W). A negative value indicatesthat this object is not available. | Integer32 Constraints: range: -1-10000 | .1.3.6.1.4.1.232.165.11.5.1.1.10 | ||||||||||||||||||||||||||||||||
pdu3OutletCurrentPercentLoadmandatory Current percent load, based on the rated current capacity. Units arepercentage, for example 80.5% will be returned as 805. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.5.1.1.11 | ||||||||||||||||||||||||||||||||
pdu3OutletVAmandatory A outlet power VA value. Units are VA. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.5.1.1.12 | ||||||||||||||||||||||||||||||||
pdu3OutletWattsmandatory A outlet power in Watts value. Units are Watts. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.5.1.1.13 | ||||||||||||||||||||||||||||||||
pdu3OutletWhmandatory An energy in kWatt-Hour value for each outlet. Units are kWh.This object is writable so that it can be reset to 0. When it is written to, the pdu3OutletWhTimer will be reset updated as well A negative value indic… | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.5.1.1.14 | ||||||||||||||||||||||||||||||||
pdu3OutletWhTimermandatory Timestamp (date and time) of outlet energy in kWh is reset. | OctetString Constraints: range: 0-22 | .1.3.6.1.4.1.232.165.11.5.1.1.15 | ||||||||||||||||||||||||||||||||
pdu3OutletPowerFactormandatory An outlet PF value. Return value is divided by 100, for example a power factorof 0.95 would be returned as 95. A negative value indicates that this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.5.1.1.16 | ||||||||||||||||||||||||||||||||
pdu3OutletVARmandatory An outlet power reactive in VAR value. Units are VAR. A negative value indicatesthat this object is not available. | Integer32 Type Constraints: range: -2147483648..2147483647 | .1.3.6.1.4.1.232.165.11.5.1.1.17 |
.1.3.6.1.4.1.232.165.11.5.2
·
1 row entry
·
9 columns
Uses the hp variant from
Command help
/opt/observium/mibs/hp.
Walk pdu3OutletControlTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CPQPOWER-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CPQPOWER-MIB::pdu3OutletControlTable'
Aggregate Object with number of entries equal to Number of PDU (pdu3IdentIndex) and Number of outlets per PDU (pdu3OutletIndex).
The Outlet table entry containing the type, voltage, current etc.
Indexes
| Column | Syntax | OID | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|
pdu3OutletControlStatusmandatory current state of a control outlet. | Enumeration Enumerated Values:
| .1.3.6.1.4.1.232.165.11.5.2.1.1 | ||||||||
pdu3OutletControlOffCmdmandatory When write, once issued, the outlet will turn Off immediately.0-n: Time in seconds until the outlet command is issued -1: Cancel a pending outlet Off command When read, returns -1 if no command is pending, or the curr… | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.11.5.2.1.2 | ||||||||
pdu3OutletControlOnCmdmandatory When write, once issued, the outlet will turn On immediately.0-n: Time in seconds until the outlet command is issued -1: Cancel a pending outlet On command When read, returns -1 if no command is pending, or the curren… | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.11.5.2.1.3 | ||||||||
pdu3OutletControlRebootCmdmandatory When write, for outlets that are On prior to this Reboot command, they will switch Off immediately when the command is issued, remain Off for outletControlRebootOffTime seconds, and then turn back On. For outlets tha… | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.11.5.2.1.4 | ||||||||
pdu3OutletControlPowerOnStatemandatory Determines the outlet state when power is applied to the unit.1 : not restart at device startup 2 : should sequence back ON in line with outletControlSequenceTime 3 : should take the state the outlet had when power was… | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.11.5.2.1.5 | ||||||||
pdu3OutletControlSequenceDelaymandatory Time delay in seconds from when a Global Sequence On command is issued towhen the command is executed on this outlet. This delay is also used as a power-on delay. Set to -1 to exclude this outlet from Global Sequence … | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.11.5.2.1.6 | ||||||||
pdu3OutletControlRebootOffTimemandatory Time delay in seconds that the outlet should remain in the Off state when executing a Reboot command. | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.11.5.2.1.7 | ||||||||
pdu3OutletControlSwitchablemandatory Determines the outlet capability to be controlled On/Off from the communication channels.1 : control On/Off enabled 2 : control On/Off disabled. | Enumerationr/w Enumerated Values:
| .1.3.6.1.4.1.232.165.11.5.2.1.8 | ||||||||
pdu3OutletControlShutoffDelaymandatory Time delay in seconds that could be taken in account before shutting of the outlet.An application which need to shutoff properly an outlet will read this parameter first then write it to the command pdu3OutletControlOf… | Integer32r/w Constraints: range: -1-99999 | .1.3.6.1.4.1.232.165.11.5.2.1.9 |