sCellEventTrap_9_f

CPQHSV110V3-MIB · .1.3.6.1.4.1.232.0.13602319

Object

notification
Severity: Warning -- not failed but attention recommended or required. The temperature within the HSV110 controller identified in the handle field is approaching its trip point. The value.ul1 field contains the current temperature reading from I2C sensor 1 in degrees celsius while the value.ul2 field contains the adjusted reading from I2C sensor 2. The secondary_id field contains the set temperature trip point in Celsius.

Context

MIB
CPQHSV110V3-MIB
OID
.1.3.6.1.4.1.232.0.13602319
Type
notification
Status
current
Parent
compaq

Notifications are emitted by an agent; they cannot be read with snmpget or walked.