CPQHSV110V3-MIB

Source file
CPQHSV110V3-MIB
Last revised
Not declared
Imported Objects
RFC-1212 OBJECT-TYPE (no object page)
RFC-1215 TRAP-TYPE (no object page)
RFC1155-SMI enterprises
RFC1213-MIB DisplayString
Objects (74)
.1.3.6.1.4.1.232
.1.3.6.1.4.1.232.136
.1.3.6.1.4.1.232.136.1
.1.3.6.1.4.1.232.136.1.1
agManufacturer mandatory
.1.3.6.1.4.1.232.136.1.1.1
agMajVersion mandatory
.1.3.6.1.4.1.232.136.1.1.2
agMinVersion mandatory
.1.3.6.1.4.1.232.136.1.1.3
agHostName mandatory
.1.3.6.1.4.1.232.136.1.1.4
agEnterprise mandatory
ObjectIdentifier
.1.3.6.1.4.1.232.136.1.1.5
agDescription mandatory
.1.3.6.1.4.1.232.136.1.1.6
agStatusTable mandatory
.1.3.6.1.4.1.232.136.1.1.7
agentEntry mandatory
.1.3.6.1.4.1.232.136.1.1.7.1
agentEntryIndex mandatory
.1.3.6.1.4.1.232.136.1.1.7.1.1
agentStatus mandatory
Enumeration
.1.3.6.1.4.1.232.136.1.1.7.1.2
agentEventCode mandatory
.1.3.6.1.4.1.232.136.1.1.7.1.3
agentEventLevel mandatory
.1.3.6.1.4.1.232.136.1.1.7.1.4
agentEventTimeDate mandatory
.1.3.6.1.4.1.232.136.1.1.7.1.5
.1.3.6.1.4.1.232.136.1.1.7.1.6
.1.3.6.1.4.1.232.136.1.2
srvCPU mandatory
.1.3.6.1.4.1.232.136.1.2.1
srvComputerType mandatory
.1.3.6.1.4.1.232.136.1.2.2
srvModel mandatory
.1.3.6.1.4.1.232.136.1.2.3
srvSubModel mandatory
.1.3.6.1.4.1.232.136.1.2.4
srvBiosVersion mandatory
.1.3.6.1.4.1.232.136.1.2.5
srvOS mandatory
.1.3.6.1.4.1.232.136.1.2.6
srvOSMajVersion mandatory
.1.3.6.1.4.1.232.136.1.2.7
srvOSMinVersion mandatory
.1.3.6.1.4.1.232.136.1.2.8
.1.3.6.1.4.1.232.136.1.3
.1.3.6.1.4.1.232.136.1.3.1
scellTotal mandatory
.1.3.6.1.4.1.232.136.1.3.1.1
scellStatusTable mandatory
.1.3.6.1.4.1.232.136.1.3.1.2
scellEntry mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1
scellEntryIndex mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.1
scellCAC mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.10
scellEIP mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.11
scellNameDateTime mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.12
scellName mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.2
scellUUID mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.3
scellStatus mandatory
Enumeration
.1.3.6.1.4.1.232.136.1.3.1.2.1.4
.1.3.6.1.4.1.232.136.1.3.1.2.1.5
scellEventTimeDate mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.6
scellEventCode mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.7
scellSWComponent mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.8
scellECode mandatory
.1.3.6.1.4.1.232.136.1.3.1.2.1.9
.1.3.6.1.4.1.232.136.1.3.2
.1.3.6.1.4.1.232.136.1.3.3
hostTotal mandatory
.1.3.6.1.4.1.232.136.1.3.3.1
hostStatusTable mandatory
.1.3.6.1.4.1.232.136.1.3.3.2
hostEntry mandatory
.1.3.6.1.4.1.232.136.1.3.3.2.1
hostEntryIndex mandatory
.1.3.6.1.4.1.232.136.1.3.3.2.1.1
hostName mandatory
.1.3.6.1.4.1.232.136.1.3.3.2.1.2
hostUUID mandatory
.1.3.6.1.4.1.232.136.1.3.3.2.1.3
hostStatus mandatory
Enumeration
.1.3.6.1.4.1.232.136.1.3.3.2.1.4
nsc
.1.3.6.1.4.1.232.136.1.3.4
nscTotal mandatory
.1.3.6.1.4.1.232.136.1.3.4.1
nscStatusTable mandatory
.1.3.6.1.4.1.232.136.1.3.4.2
nscEntry mandatory
.1.3.6.1.4.1.232.136.1.3.4.2.1
nscEntryIndex mandatory
.1.3.6.1.4.1.232.136.1.3.4.2.1.1
nscName mandatory
.1.3.6.1.4.1.232.136.1.3.4.2.1.2
nscUUID mandatory
.1.3.6.1.4.1.232.136.1.3.4.2.1.3
nscStatus mandatory
Enumeration
.1.3.6.1.4.1.232.136.1.3.4.2.1.4
.1.3.6.1.4.1.232.136.1.3.8
shelfTotal mandatory
.1.3.6.1.4.1.232.136.1.3.8.1
shelfStatusTable mandatory
.1.3.6.1.4.1.232.136.1.3.8.2
shelfEntry mandatory
.1.3.6.1.4.1.232.136.1.3.8.2.1
shelfEntryIndex mandatory
.1.3.6.1.4.1.232.136.1.3.8.2.1.1
shelfStatus mandatory
Enumeration
.1.3.6.1.4.1.232.136.1.3.8.2.1.2
shelfId mandatory
.1.3.6.1.4.1.232.136.1.3.8.2.1.3
shelfElementType mandatory
.1.3.6.1.4.1.232.136.1.3.8.2.1.4
shelfElementNum mandatory
.1.3.6.1.4.1.232.136.1.3.8.2.1.5
shelfErrorCode mandatory
.1.3.6.1.4.1.232.136.1.3.8.2.1.6
.1.3.6.1.4.1.232.136.1.4
maHSVMibRevMajor mandatory
.1.3.6.1.4.1.232.136.1.4.1
maHSVMibRevMinor mandatory
.1.3.6.1.4.1.232.136.1.4.2
Dependencies (7) 4 direct · 3 transitive Show tree and compile order Hide dependency details

Each imported module is resolved in the importing module's source directory first, then through the normal default-variant rules.

Dependency tree
Dependency-first compile order
  1. RFC-1212rfc
  2. RFC-1215rfc
  3. RFC1155-SMIrfc
  4. SNMPv2-SMIrfc
  5. SNMPv2-TCrfc
  6. IANAifType-MIBrfc
  7. RFC1213-MIBrfc
  8. CPQHSV110V3-MIBhpselected
Notifications / Traps (1078)
NameOIDDescription
.1.3.6.1.4.1.232.0.136000001
Object Already Exists
.1.3.6.1.4.1.232.0.136000002
Supplied Buffer Too Small
.1.3.6.1.4.1.232.0.136000003
Object Already Assigned
.1.3.6.1.4.1.232.0.136000004
Insufficient Available Data Storage
.1.3.6.1.4.1.232.0.136000005
Internal Error
.1.3.6.1.4.1.232.0.136000006
Invalid status for logical disk
.1.3.6.1.4.1.232.0.136000007
Invalid Class
.1.3.6.1.4.1.232.0.136000008
Invalid Function
.1.3.6.1.4.1.232.0.136000009
Invalid Logical Disk Block State
.1.3.6.1.4.1.232.0.136000010
Invalid Loop Configuration
.1.3.6.1.4.1.232.0.136000011
Invalid Parameter
.1.3.6.1.4.1.232.0.136000012
Invalid Parameter handle
.1.3.6.1.4.1.232.0.136000013
Invalid Parameter Id
.1.3.6.1.4.1.232.0.136000014
Invalid Quorum Configuration
.1.3.6.1.4.1.232.0.136000015
Invalid Target Handle
.1.3.6.1.4.1.232.0.136000016
Invalid Target Id
.1.3.6.1.4.1.232.0.136000017
Invalid Time
.1.3.6.1.4.1.232.0.136000018
Media is Inaccessible
.1.3.6.1.4.1.232.0.136000019
No Fibre Channel Port
.1.3.6.1.4.1.232.0.136000020
No Image
.1.3.6.1.4.1.232.0.136000021
No Permission
.1.3.6.1.4.1.232.0.136000022
Storage system not initialized
.1.3.6.1.4.1.232.0.136000023
Not a Loop Port
.1.3.6.1.4.1.232.0.136000024
Not a Participating Controller
.1.3.6.1.4.1.232.0.136000025
Objects in your system are in use, and their state prevents the operation you wish to perform.
.1.3.6.1.4.1.232.0.136000026
Parameter Object Does Not Exist
.1.3.6.1.4.1.232.0.136000027
Target Object Does Not Exist
.1.3.6.1.4.1.232.0.136000028
Timeout
.1.3.6.1.4.1.232.0.136000029
Unknown Id
.1.3.6.1.4.1.232.0.136000030
Unknown Parameter Handle
.1.3.6.1.4.1.232.0.136000031
Unrecoverable Media Error
.1.3.6.1.4.1.232.0.136000032
Invalid State
.1.3.6.1.4.1.232.0.136000033
Transport Error
.1.3.6.1.4.1.232.0.136000034
Volume is Missing
.1.3.6.1.4.1.232.0.136000035
Invalid Cursor
.1.3.6.1.4.1.232.0.136000036
Invalid Target for the Operation
.1.3.6.1.4.1.232.0.136000037
No More Events
.1.3.6.1.4.1.232.0.136000038
Lock Busy
.1.3.6.1.4.1.232.0.136000039
Time Not Set
.1.3.6.1.4.1.232.0.136000040
Not a Supported Version
.1.3.6.1.4.1.232.0.136000041
No Logical Disk for Vdisk
.1.3.6.1.4.1.232.0.136000042
Logical disk Presented
.1.3.6.1.4.1.232.0.136000043
Operation Denied On Slave
.1.3.6.1.4.1.232.0.136000044
Not licensed for data replication
.1.3.6.1.4.1.232.0.136000045
Not DR group member
.1.3.6.1.4.1.232.0.136000046
Invalid DR mode
.1.3.6.1.4.1.232.0.136000047
Invalid DR State
.1.3.6.1.4.1.232.0.136000048
Security credentials needed. Please update your system's ID and password in the Storage System Access menu.
.1.3.6.1.4.1.232.0.136000049
Security credentials supplied were invalid. Please update your system's ID and password in the Storage System Access menu.
.1.3.6.1.4.1.232.0.136000050
Security credentials supplied were invalid. Please update your system's ID and password in the Storage System Access menu.
.1.3.6.1.4.1.232.0.136000051
Storage system connection down
.1.3.6.1.4.1.232.0.136000052
DR group empty
.1.3.6.1.4.1.232.0.136000053
Incompatible attribute
.1.3.6.1.4.1.232.0.136000054
Vdisk is a DR group member
.1.3.6.1.4.1.232.0.136000055
Vdisk is a DR log unit
.1.3.6.1.4.1.232.0.136000056
Cache batteries failed or missing.
.1.3.6.1.4.1.232.0.136000057
Vdisk is not presented
.1.3.6.1.4.1.232.0.136000058
Other controller failed
.1.3.6.1.4.1.232.0.136000059
Maximum Number of Objects Exceeded.
.1.3.6.1.4.1.232.0.136000060
Max size
.1.3.6.1.4.1.232.0.136000061
Password mismatch. Please update your system's password in the Storage System Access menu. Continued attempts to access this storage system with an incorrect password will disable management of this storage system.
.1.3.6.1.4.1.232.0.136000062
DR group is merging
.1.3.6.1.4.1.232.0.136000063
DR group is logging
.1.3.6.1.4.1.232.0.136000064
Connection is suspended
.1.3.6.1.4.1.232.0.136000065
Bad image header
.1.3.6.1.4.1.232.0.136000066
Bad image
.1.3.6.1.4.1.232.0.136000067
Image too large
.1.3.6.1.4.1.232.0.136000068
EMU not available
.1.3.6.1.4.1.232.0.136000069
EMU indefinite delay
.1.3.6.1.4.1.232.0.136000070
Image incompatible with system configuration. Version conflict in upgrade or downgrade not allowed.
.1.3.6.1.4.1.232.0.136000071
Bad image segment
.1.3.6.1.4.1.232.0.136000072
Image already loaded
.1.3.6.1.4.1.232.0.136000073
Image Write Error
.1.3.6.1.4.1.232.0.136000074
Logical Disk Sharing
.1.3.6.1.4.1.232.0.136000075
Bad Image Size
.1.3.6.1.4.1.232.0.136000076
Image Load Busy
.1.3.6.1.4.1.232.0.136000077
Volume Failure Predicted
.1.3.6.1.4.1.232.0.136000078
Background allocation on the destination member is in progress. This action must complete before any others can be initiated .
.1.3.6.1.4.1.232.0.136000079
Invalid Predecessor Vdisk Condition
.1.3.6.1.4.1.232.0.136000080
Invalid Volume Usage
.1.3.6.1.4.1.232.0.136000081
Minimum Volumes In Disk Group
.1.3.6.1.4.1.232.0.136000082
Shutdown In Progress
.1.3.6.1.4.1.232.0.136000083
Not Ready
.1.3.6.1.4.1.232.0.136000084
Is Snapshot
.1.3.6.1.4.1.232.0.136000085
Cannot add or remove DR group member. Mirror cache must be active for this Vdisk. Check controller cache condition.
.1.3.6.1.4.1.232.0.136000086
Inoperative
.1.3.6.1.4.1.232.0.136000087
Disk group inoperative or less than 8 disks in group
.1.3.6.1.4.1.232.0.136000088
Storage system inoperative
.1.3.6.1.4.1.232.0.136000089
Failsafe Locked
.1.3.6.1.4.1.232.0.136000090
Data Flush Incomplete
.1.3.6.1.4.1.232.0.136000091
Redundancy Mirrored Inoperative
.1.3.6.1.4.1.232.0.136000092
Duplicate LUN
.1.3.6.1.4.1.232.0.136000093
Other remote controller failed
.1.3.6.1.4.1.232.0.136000094
Unknown remote Vdisk
.1.3.6.1.4.1.232.0.136000095
Unknown remote DR group
.1.3.6.1.4.1.232.0.136000096
PLDMC failed
.1.3.6.1.4.1.232.0.136000097
Storage system could not be locked. System busy. Try command again.
.1.3.6.1.4.1.232.0.136000098
Error on remote storage system.
.1.3.6.1.4.1.232.0.136000099
This operation can only be completed when the source-destination connection is down.
.1.3.6.1.4.1.232.0.136000100
Login required - password changed.
.1.3.6.1.4.1.232.0.136000101
Numerous login attempts have been detected that uses an incorrect password. Please update your system's password in the Storage System Access menu.
.1.3.6.1.4.1.232.0.136000102
Invalid cookie
.1.3.6.1.4.1.232.0.136000103
Login timed out
.1.3.6.1.4.1.232.0.136000104
Max snapshot depth reached
.1.3.6.1.4.1.232.0.136000105
Attribute mismatch
.1.3.6.1.4.1.232.0.136000106
The password has been set in Command View EVA. The same password still needs to be set in the controllers.
.1.3.6.1.4.1.232.0.136000107
Not host port
.1.3.6.1.4.1.232.0.136000108
Duplicate Lun WWID
.1.3.6.1.4.1.232.0.136000109
System Inoperative
.1.3.6.1.4.1.232.0.136000110
SnapClone Active
.1.3.6.1.4.1.232.0.136000111
Emu Load Busy
.1.3.6.1.4.1.232.0.136000112
Duplicate User Name
.1.3.6.1.4.1.232.0.136000113
Drive Reserved For Code Load
.1.3.6.1.4.1.232.0.136000114
Already Presented
.1.3.6.1.4.1.232.0.136000115
Invalid remote storage system
.1.3.6.1.4.1.232.0.136000116
No Lock
.1.3.6.1.4.1.232.0.136000117
Maximum Number of Members Exceeded
.1.3.6.1.4.1.232.0.136000118
Max Destinations
.1.3.6.1.4.1.232.0.136000119
Empty User Name
.1.3.6.1.4.1.232.0.136000120
Storage system already initialized
.1.3.6.1.4.1.232.0.136000121
Already Open
.1.3.6.1.4.1.232.0.136000122
Session Not Open
.1.3.6.1.4.1.232.0.136000123
Not Marked Inoperative
.1.3.6.1.4.1.232.0.136000124
Media Not Available
.1.3.6.1.4.1.232.0.136000125
Battery System Failed
.1.3.6.1.4.1.232.0.136000126
DR Group Member Is Cache Data Lost
.1.3.6.1.4.1.232.0.136000127
Internal Lock Collision
.1.3.6.1.4.1.232.0.136000128
OCP Error
.1.3.6.1.4.1.232.0.136000129
Mirror Offline
.1.3.6.1.4.1.232.0.136000130
This operation cannot be completed if failsafe mode is enabled.
.1.3.6.1.4.1.232.0.136000131
Drive firmware load abort due to Raid0 virtual disk(s).
.1.3.6.1.4.1.232.0.136000132
Fibre channel ports are unavailable.
.1.3.6.1.4.1.232.0.136000133
The storage system has reached its maximum number of DR relationship.
.1.3.6.1.4.1.232.0.136001
An EMU Informational event has occurred
scellNameDateTime: StorageCell name, and date/time
emuShelfId: disk shelf number in the cabinet
emuElementType: the element type
01: Disk
02: Pwr Supply
03: Fan
04: Temp Sensor
06: Alarm Horn
07: EMU
12: LCD
15: Xcvr
16: Lang
17: Comm Port
18: Volt Sensor
19: Amp Sensor
128:Encl
130:Back plane
emuErrorCode: error number
.1.3.6.1.4.1.232.0.136001000
Logical Disk Condition Change
.1.3.6.1.4.1.232.0.136001001
Storage system is FULL **critical**
.1.3.6.1.4.1.232.0.136001002
Storage system is almost FULL. Disk group at or above maximum capacity warning level.
.1.3.6.1.4.1.232.0.136001003
Controller Cache Battery Condition Change
.1.3.6.1.4.1.232.0.136001004
Controller Cache Condition Change
.1.3.6.1.4.1.232.0.136001005
Controller Condition Change
.1.3.6.1.4.1.232.0.136001006
Controller FC Port Condition Change
.1.3.6.1.4.1.232.0.136001007
Physical Device Condition Change
.1.3.6.1.4.1.232.0.136001008
Physical Store Condition Change
.1.3.6.1.4.1.232.0.136001009
Host condition change
.1.3.6.1.4.1.232.0.136001010
Storage system time has been set
.1.3.6.1.4.1.232.0.136001011
Volume Condition change
.1.3.6.1.4.1.232.0.136001012
Volume insufficient_resources condition change
.1.3.6.1.4.1.232.0.136001013
Volume Quorum Disk change
.1.3.6.1.4.1.232.0.136001014
The state of an object in the system has changed. View adjacent events for more detail.
.1.3.6.1.4.1.232.0.136002
An EMU Non-critical event has occurred
scellNameDateTime: StorageCell name, and date/time
emuShelfId: disk shelf number in the cabinet
emuElementType: the element type
01: Disk
02: Pwr Supply
03: Fan
04: Temp Sensor
06: Alarm Horn
07: EMU
12: LCD
15: Xcvr
16: Lang
17: Comm Port
18: Volt Sensor
19: Amp Sensor
128:Encl
130:Back plane
emuErrorCode: error number
.1.3.6.1.4.1.232.0.136002001
Startup Failed
.1.3.6.1.4.1.232.0.136002002
Management agent event log cleared successfully
.1.3.6.1.4.1.232.0.136002003
Invalid name specified for storage system
.1.3.6.1.4.1.232.0.136002004
Storage system is not initialized
.1.3.6.1.4.1.232.0.136002006
Invalid name specified for Vdisk
.1.3.6.1.4.1.232.0.136002007
Vdisk name exceeds maximum length
.1.3.6.1.4.1.232.0.136002008
Invalid parameter specified for Vdisk
.1.3.6.1.4.1.232.0.136002010
Specified Vdisk size exceeds available size
.1.3.6.1.4.1.232.0.136002011
There are not enough disk drives to create a disk group
.1.3.6.1.4.1.232.0.136002012
Number of devices exceeds the available number of disks
.1.3.6.1.4.1.232.0.136002013
Number of devices is less than the minimum number required to create a disk group
.1.3.6.1.4.1.232.0.136002016
Completed unpresenting virtual disk to host
.1.3.6.1.4.1.232.0.136002021
Invalid refresh interval value. Should be numeric and non-negative.
.1.3.6.1.4.1.232.0.136002022
Invalid security message. Should not be blank.
.1.3.6.1.4.1.232.0.136002023
Vdisk Create Complete
.1.3.6.1.4.1.232.0.136002025
Storage system successfully initialized
.1.3.6.1.4.1.232.0.136002026
Device Added Successfully
.1.3.6.1.4.1.232.0.136002030
Refresh Interval Changed
.1.3.6.1.4.1.232.0.136002031
Security Message Changed
.1.3.6.1.4.1.232.0.136002032
Present Vdisk to a Host - Complete
.1.3.6.1.4.1.232.0.136002033
Control Startup Complete
.1.3.6.1.4.1.232.0.136002034
Change Device Usage Complete
.1.3.6.1.4.1.232.0.136002035
Control Shutdown - Complete
.1.3.6.1.4.1.232.0.136002036
Controller Shutdown - Complete
.1.3.6.1.4.1.232.0.136002038
Control Memory Allocation Failure
.1.3.6.1.4.1.232.0.136002040
Access level denied or session activity timeout. Please log in again.
.1.3.6.1.4.1.232.0.136002041
Vdisk Snapshot - Completed
.1.3.6.1.4.1.232.0.136002042
Vdisk Snapclone - Completed
.1.3.6.1.4.1.232.0.136002047
Host record added successfully
.1.3.6.1.4.1.232.0.136002048
Logical component deleted successfully
.1.3.6.1.4.1.232.0.136002049
Invalid host adapter ID
.1.3.6.1.4.1.232.0.136002050
Specified device is already a member of the system
.1.3.6.1.4.1.232.0.136002051
Create Folder - Completed
.1.3.6.1.4.1.232.0.136002052
Change Object Properties - Completed
.1.3.6.1.4.1.232.0.136002057
Completed disk group creation
.1.3.6.1.4.1.232.0.136002058
Added host port
.1.3.6.1.4.1.232.0.136002059
Discarded host port
.1.3.6.1.4.1.232.0.136002060
EMU/Shelf code load complete
.1.3.6.1.4.1.232.0.136002061
Operation will exceed the available capacity of the disk group
.1.3.6.1.4.1.232.0.136002062
Controller(s) code load complete
.1.3.6.1.4.1.232.0.136002063
The target device is not in the right condition to perform the operation
.1.3.6.1.4.1.232.0.136002064
Storage system Device Addition Policy changed successfully
.1.3.6.1.4.1.232.0.136002065
Maximum number of disk groups exceeded
.1.3.6.1.4.1.232.0.136002066
Nsa object discard failed.
.1.3.6.1.4.1.232.0.136002067
There are not enough disks to meet the minimum number requirement
.1.3.6.1.4.1.232.0.136002068
Entry added successfully in the password file
.1.3.6.1.4.1.232.0.136002069
Entry updated successfully in the password file
.1.3.6.1.4.1.232.0.136002070
Entry discarded successfully in the password file
.1.3.6.1.4.1.232.0.136002071
Storage system is not responding in a timely manner and has been placed into an unknown state. This may be due to a prior command with an excessively long execution time, high I/O load, or a network communications error. Recovery will automatically occur when the storage system is able to respond.
.1.3.6.1.4.1.232.0.136002072
Object not found. Operation on this object is completed
.1.3.6.1.4.1.232.0.136002073
There is no more available space to create a Vdisk
.1.3.6.1.4.1.232.0.136002074
Name or comments contains invalid character(s)
.1.3.6.1.4.1.232.0.136002075
Duplicate - Another object with the same name exists.
.1.3.6.1.4.1.232.0.136002076
No healthy disk group(s) to create a Vdisk. Resolve any abnormal conditions in the disk group first.
.1.3.6.1.4.1.232.0.136002077
Operating System ID must be a valid number.
.1.3.6.1.4.1.232.0.136002078
Watchdog successfully started
.1.3.6.1.4.1.232.0.136002079
Watchdog successfully stopped
.1.3.6.1.4.1.232.0.136002080
Delete Event Config List failed
.1.3.6.1.4.1.232.0.136002081
Disk group meltdown repaired successfully.
.1.3.6.1.4.1.232.0.136002082
There are no available LUNs to present this Vdisk.
.1.3.6.1.4.1.232.0.136002083
Controller time synchronization turned on.
.1.3.6.1.4.1.232.0.136002084
Controller time synchronization turned off.
.1.3.6.1.4.1.232.0.136002085
System login failed. Invalid password.
.1.3.6.1.4.1.232.0.136002086
System is not set for password validation.
.1.3.6.1.4.1.232.0.136002087
Agent is already logged in to this system.
.1.3.6.1.4.1.232.0.136002088
Storage system time set to custom time. Controller time synchronization automatically turned off.
.1.3.6.1.4.1.232.0.136002089
Storage system time set to SAN appliance time.
.1.3.6.1.4.1.232.0.136002090
Storage system time set to browser time. Controller time synchronization automatically turned off.
.1.3.6.1.4.1.232.0.136002091
Storage system time set to controller time. Controller time synchronization automatically turned off.
.1.3.6.1.4.1.232.0.136002092
Unable to find DR Group on remote storage system.
.1.3.6.1.4.1.232.0.136002093
A host must have at least one port. Cannot delete the only host port available.
.1.3.6.1.4.1.232.0.136002095
Host creation failed. Maximum number of hosts reached.
.1.3.6.1.4.1.232.0.136002096
Port already exists for this host.
.1.3.6.1.4.1.232.0.136002097
Error reading parameter string. String is empty.
.1.3.6.1.4.1.232.0.136002098
Command could not be completed on Master. Controller not found.
.1.3.6.1.4.1.232.0.136002099
Command could not be completed on Slave. Controller not found.
.1.3.6.1.4.1.232.0.136002100
Password access for all known storage systems is already enabled or set.
.1.3.6.1.4.1.232.0.136002102
The local storage system has reached the maximum allowable DR relationship.
.1.3.6.1.4.1.232.0.136002103
The remote storage system has reached the maximum allowable DR relationship.
.1.3.6.1.4.1.232.0.13600256
Severity: Normal -- informational in nature. During Executive Services initialization the system time value was set to the value contained in the time field. The action field contains one of the following codes which describes the condition that caused the time value to be chosen: <UL><LI>0 = TOY clock unavailable; time reset to default date and time. <LI>1 = TOY clock time value was less than or equal to the last known time value previously stored in nonvolatile memory; time reset to default date and time. <LI>2 = EDC was bad for last known time value previously stored in nonvolatile memory; time reset to default date and time. <LI>3 = TOY clock not running; time reset to default date and time. <LI>4 = TOY clock time value believed to be accurate; time set to TOY clock time value. </UL>
.1.3.6.1.4.1.232.0.13600257
Severity: Normal -- informational in nature. The system time value was set to the value contained in the time field by a call to the EXEC$SET_TIME service. As part of setting the time in a dual HSV110 controller configuration, the times are synchronized. The action field contains one of the following codes which describes the action taken: <UL><LI>0 = The time was set to the time value on this HSV110 controller. <LI>1 = The master HSV110 controller requested the slave HSV110 controller to set its time to the time value. <LI>2 = The slave HSV110 controller set the local time to the time value. <LI>3 = The HSV110 controller's TOY clock was set to the time value. </UL>
.1.3.6.1.4.1.232.0.136003
An EMU Critical event has occurred
scellNameDateTime: StorageCell name, and date/time
emuShelfId: disk shelf number in the cabinet
emuElementType: the element type
01: Disk
02: Pwr Supply
03: Fan
04: Temp Sensor
06: Alarm Horn
07: EMU
12: LCD
15: Xcvr
16: Lang
17: Comm Port
18: Volt Sensor
19: Amp Sensor
128:Encl
130:Back plane
emuErrorCode: error number
.1.3.6.1.4.1.232.0.136003001
Event Manager Offline
.1.3.6.1.4.1.232.0.136003002
Event Manager Online
.1.3.6.1.4.1.232.0.136003003
Event Manager - Startup Failed
.1.3.6.1.4.1.232.0.136003004
Event Manager - Startup Complete
.1.3.6.1.4.1.232.0.136003007
Event Manager - Shutdown Complete
.1.3.6.1.4.1.232.0.136003009
Unable to open NSA Local Event Log File
.1.3.6.1.4.1.232.0.136003012
Unable to open Local Temp Event File - possibly no initialized SC
.1.3.6.1.4.1.232.0.136003013
Unable to clear NSA Local Event Log File
.1.3.6.1.4.1.232.0.136003015
Unable to clear NSA Event Log File
.1.3.6.1.4.1.232.0.136003016
Local log file found on startup
.1.3.6.1.4.1.232.0.136003017
Event Queue Flush Error
.1.3.6.1.4.1.232.0.136003019
EM File Manager Online
.1.3.6.1.4.1.232.0.136003020
EM File Manager Offline
.1.3.6.1.4.1.232.0.136003021
EM Log Manager Online
.1.3.6.1.4.1.232.0.136003022
EM Log Manager Offline
.1.3.6.1.4.1.232.0.136003024
Local NSA logfile is empty
.1.3.6.1.4.1.232.0.136003025
Event Queue Online
.1.3.6.1.4.1.232.0.136003028
Status Descriptions Unavailable
.1.3.6.1.4.1.232.0.136003029
EM Description Mngr Online
.1.3.6.1.4.1.232.0.136003035
EM: NSA log file unavailable
.1.3.6.1.4.1.232.0.136003036
EM Memory Allocation Error
.1.3.6.1.4.1.232.0.136003037
EM: Local Event Configuration File Unavailable
.1.3.6.1.4.1.232.0.136003038
EM: MLD Notification File Unavailable - retrieving local backup copy
.1.3.6.1.4.1.232.0.136003039
EM: Local Notification Host List File Unavailable
.1.3.6.1.4.1.232.0.136003044
Override this description with missing filename
.1.3.6.1.4.1.232.0.136003045
Invalid storage system event sequence number - can't retrieve event
.1.3.6.1.4.1.232.0.136003046
Invalid SC termination event sequence number - can't retrieve event
.1.3.6.1.4.1.232.0.136003047
EM: Event config file unavailable from MLD - retrieving local backup copy
.1.3.6.1.4.1.232.0.136003048
EM: Local user defined event state file unavailable
.1.3.6.1.4.1.232.0.136003049
EM: EMU event monitoring thread unable to start
.1.3.6.1.4.1.232.0.136003050
EM: EMU event - this description will be overwritten
.1.3.6.1.4.1.232.0.136003051
EM: Failed to write Event Config file to MLD
.1.3.6.1.4.1.232.0.136003053
EM: Event Configuration Filename Error or File empty
.1.3.6.1.4.1.232.0.136003054
EM: Notification Hostlist Filename Error or File empty
.1.3.6.1.4.1.232.0.136003055
EM: Event Config List Object Reference Error
.1.3.6.1.4.1.232.0.136003056
EM: SC Parse File successfully uploaded
.1.3.6.1.4.1.232.0.136003057
EM: SC Parse File upload failed
.1.3.6.1.4.1.232.0.136003058
EM: Contents of the uploaded parse file invalid - unexpected contents
.1.3.6.1.4.1.232.0.136003059
EM: Parse file is empty
.1.3.6.1.4.1.232.0.136003060
Storage system being shutdown due to a command failure.
.1.3.6.1.4.1.232.0.136003061
EM: Could not retrieve a storage system event
.1.3.6.1.4.1.232.0.136003062
EM: Init SC Event config list failed
.1.3.6.1.4.1.232.0.136003063
Could not initialize Comm infrastructure for event logging to system log
.1.3.6.1.4.1.232.0.136003064
EM: Storage system pointer is NULL!
.1.3.6.1.4.1.232.0.136003065
EM: Failed to log event to the Appliance event log: check if log is full
.1.3.6.1.4.1.232.0.136003066
EM: Description Mngr initialize storage system failed
.1.3.6.1.4.1.232.0.136003067
EM: Description file too small. File read problem Or Incomplete file.
.1.3.6.1.4.1.232.0.136003068
EM: Can't init NT Event object pointer
.1.3.6.1.4.1.232.0.136003069
EM: Can't init NT Notification object pointer
.1.3.6.1.4.1.232.0.136003070
EM: Appliance Event Logging Failure - log may be full
.1.3.6.1.4.1.232.0.136003071
EM: SCMI returned bad additional events number
.1.3.6.1.4.1.232.0.136003072
EM: SCMI returned zero sized SC Event
.1.3.6.1.4.1.232.0.136003075
EventQueue index passed is out of bounds
.1.3.6.1.4.1.232.0.136003076
EM: An abnormal number of duplicate events logged - dropping duplicates
.1.3.6.1.4.1.232.0.136003077
EM: Update of the MLD Status Description file failed
.1.3.6.1.4.1.232.0.136003078
EM: NsaStatusDescriptions.txt open file error
.1.3.6.1.4.1.232.0.136003079
EM: NsaStatusDescriptions.txt file error - file size discrepancy from mld list
.1.3.6.1.4.1.232.0.136003080
SC Event Log has been cleared and restarted. Possible RAID1 Meltdown.
.1.3.6.1.4.1.232.0.136003081
Invalid logType parameter
.1.3.6.1.4.1.232.0.136003083
Log file is empty
.1.3.6.1.4.1.232.0.136003084
Storage System with this WWN is not visible to this agent or the WWN is invalid
.1.3.6.1.4.1.232.0.136003086
Parsefile for current firmware version not found. Upload correct parse file.
.1.3.6.1.4.1.232.0.136003090
The contents of this file appear to be invalid
.1.3.6.1.4.1.232.0.136003091
The MIB failed to build due to a missing parse file.
.1.3.6.1.4.1.232.0.136003092
MLD description file is older than local file but system is downrev
.1.3.6.1.4.1.232.0.136003094
System is initialized: can't get activeQ events
.1.3.6.1.4.1.232.0.136003095
Failed to write file - file could not be opened.
.1.3.6.1.4.1.232.0.136004
An EMU Unrecoverable event has occurred
scellNameDateTime: StorageCell name, and date/time
emuShelfId: disk shelf number in the cabinet
emuElementType: the element type
01: Disk
02: Pwr Supply
03: Fan
04: Temp Sensor
06: Alarm Horn
07: EMU
12: LCD
15: Xcvr
16: Lang
17: Comm Port
18: Volt Sensor
19: Amp Sensor
128:Encl
130:Back plane
emuErrorCode: error number
.1.3.6.1.4.1.232.0.136004000
MLD Manager Subsystem Error
.1.3.6.1.4.1.232.0.136004001
MLD Manager Offline
.1.3.6.1.4.1.232.0.136004004
MLD Manager Startup Complete
.1.3.6.1.4.1.232.0.136004005
MLD Manager Abnormal Startup
.1.3.6.1.4.1.232.0.136004007
MLD Manager Shutdown Complete
.1.3.6.1.4.1.232.0.136004011
Invalid Host IP Address specified
.1.3.6.1.4.1.232.0.136004012
Unable to open the NsaMldMgr.dat file for Write
.1.3.6.1.4.1.232.0.136004013
Unable to open the NsaMldMgr.dat file for Read
.1.3.6.1.4.1.232.0.136004014
Agent Uid does not exist
.1.3.6.1.4.1.232.0.136004015
Unable to find object
.1.3.6.1.4.1.232.0.136004016
Unable to store object
.1.3.6.1.4.1.232.0.136004017
Unable to find storage system object
.1.3.6.1.4.1.232.0.136004018
Unable to create MLD
.1.3.6.1.4.1.232.0.136004020
lastSafeChoiceDelay Expired
.1.3.6.1.4.1.232.0.136004021
crashDetectDelay Expired
.1.3.6.1.4.1.232.0.136004023
Unable to read Copy1 of MLD
.1.3.6.1.4.1.232.0.136004024
Copy 1 of MLD Invalid
.1.3.6.1.4.1.232.0.136004025
Invalid Copy block of MLD
.1.3.6.1.4.1.232.0.136004027
MLD database capacity not equal to true MLD capacity
.1.3.6.1.4.1.232.0.136004028
Backup range out of bounds of copy 1 range
.1.3.6.1.4.1.232.0.136004029
MLD Manager Lock Crash DetectDelay has expired, just taking lock!
.1.3.6.1.4.1.232.0.136004030
MLD Copy 1 Restored
.1.3.6.1.4.1.232.0.136004031
MLD Copy 2 Restored
.1.3.6.1.4.1.232.0.136004032
Unable to find UidAssoc Object
.1.3.6.1.4.1.232.0.136004033
Unable to store UID Association Object
.1.3.6.1.4.1.232.0.136004034
Unable to find UidAssoc Object
.1.3.6.1.4.1.232.0.136004035
Unable to read last Fusion event read
.1.3.6.1.4.1.232.0.136004036
MLD Notification Queue Empty
.1.3.6.1.4.1.232.0.136004037
Unable to find Notification Object
.1.3.6.1.4.1.232.0.136004040
Unable to read Event Log Pointer
.1.3.6.1.4.1.232.0.136004041
Unable to read Event Log
.1.3.6.1.4.1.232.0.136004042
Unable to store Event Log
.1.3.6.1.4.1.232.0.136004043
Unable to read Event Log
.1.3.6.1.4.1.232.0.136004047
Previously Read Object Properties do not Match
.1.3.6.1.4.1.232.0.136004048
Previously Read Object Properties do not Match
.1.3.6.1.4.1.232.0.136004049
Unable to read Notification Host List
.1.3.6.1.4.1.232.0.136004050
Unable to store Notification Host List
.1.3.6.1.4.1.232.0.136004051
Unable to store Notification Host List and free Lock
.1.3.6.1.4.1.232.0.136004052
Unable to read Event Configuration List
.1.3.6.1.4.1.232.0.136004053
Unable to store Event Configuration List
.1.3.6.1.4.1.232.0.136004054
Unable to store Event Configuration List and free Lock
.1.3.6.1.4.1.232.0.136004058
MLD Manager Mutex Timeout error
.1.3.6.1.4.1.232.0.136004059
MLD Manager list is empty
.1.3.6.1.4.1.232.0.136005001
Monitor Startup Complete
.1.3.6.1.4.1.232.0.136005002
Monitor Startup Failed
.1.3.6.1.4.1.232.0.136005003
Monitor ShutDown Complete
.1.3.6.1.4.1.232.0.136005004
Monitor Memory Allocation Failure
.1.3.6.1.4.1.232.0.136005005
Monitor Mark Agent as Inactive
.1.3.6.1.4.1.232.0.136005006
Monitor create thread error
.1.3.6.1.4.1.232.0.136005007
Monitor create timer error
.1.3.6.1.4.1.232.0.136005008
Monitor agent registration - Complete
.1.3.6.1.4.1.232.0.136005010
Monitor initiated a storage system management shutdown because of controller failures
.1.3.6.1.4.1.232.0.136005011
Unknown storage system rediscovery complete
.1.3.6.1.4.1.232.0.136005012
Start monitoring thread for storage system - Complete
.1.3.6.1.4.1.232.0.136005013
Start monitoring thread for storage system - Fail
.1.3.6.1.4.1.232.0.136005014
Monitoring thread for storage system terminated
.1.3.6.1.4.1.232.0.136005015
Rediscover unknown storage system - Error
.1.3.6.1.4.1.232.0.136005016
Controller time synchronized to appliance time.
.1.3.6.1.4.1.232.0.136005017
Appliance and controller time checked for synchronization.
.1.3.6.1.4.1.232.0.136005018
Controller and appliance time are the same. No need to synchronize.
.1.3.6.1.4.1.232.0.136005019
Exception caught in monitoring process.
.1.3.6.1.4.1.232.0.136006001
Ready
.1.3.6.1.4.1.232.0.136006002
Index Out of Range
.1.3.6.1.4.1.232.0.136006003
Cannot access storage system. Communications error.
.1.3.6.1.4.1.232.0.136006004
No controllers found
.1.3.6.1.4.1.232.0.136006005
Invalid Index
.1.3.6.1.4.1.232.0.136006006
Memory allocation failure
.1.3.6.1.4.1.232.0.136006007
No physical stores found
.1.3.6.1.4.1.232.0.136006008
No storage system found
.1.3.6.1.4.1.232.0.136006009
No disk group found
.1.3.6.1.4.1.232.0.136006010
Too many disk groups
.1.3.6.1.4.1.232.0.136006011
No volumes found
.1.3.6.1.4.1.232.0.136006012
No Logical Disks Found
.1.3.6.1.4.1.232.0.136006013
Context ID changed during operation
.1.3.6.1.4.1.232.0.136006014
No Name
.1.3.6.1.4.1.232.0.136006015
Name Size Exceeded
.1.3.6.1.4.1.232.0.136006016
Shutdown Complete
.1.3.6.1.4.1.232.0.136006017
Mutex Creation Failure
.1.3.6.1.4.1.232.0.136006018
The command has timed out. Storage system is busy processing previous command.
.1.3.6.1.4.1.232.0.136006019
No MLD Handle Set
.1.3.6.1.4.1.232.0.136006020
Failed Transport Layer Communication - No Such Id
.1.3.6.1.4.1.232.0.136006021
Failed Transport Layer Communication - TimeOut
.1.3.6.1.4.1.232.0.136006022
No initialized storage system objects found
.1.3.6.1.4.1.232.0.136006023
No Attached Port Found
.1.3.6.1.4.1.232.0.136006024
Failed to get SCMI Object Handle
.1.3.6.1.4.1.232.0.136006025
Shutdown Both Restart And Power Off Requested
.1.3.6.1.4.1.232.0.136006026
Shutdown Drive Shelf Power Off But No Enclosure Power Off Requested
.1.3.6.1.4.1.232.0.136006027
Shutdown Disable Battery But No Enclosure Power Off Requested
.1.3.6.1.4.1.232.0.136006028
Shutdown Disable Battery But Shutdown Unconditional Requested
.1.3.6.1.4.1.232.0.136006029
Shutdown Delay Out Of Range
.1.3.6.1.4.1.232.0.136006030
Cache Write Failure
.1.3.6.1.4.1.232.0.136006031
Battery Disable Failure
.1.3.6.1.4.1.232.0.136006032
Drive Shelf Disable Failure
.1.3.6.1.4.1.232.0.136006033
Battery Disable Failed on Both Controllers Batteries
.1.3.6.1.4.1.232.0.136006034
Battery Disable Failed on This Controllers Battery
.1.3.6.1.4.1.232.0.136006035
Battery Disable Failed on the Other Controllers Battery
.1.3.6.1.4.1.232.0.136006036
Requested disk failure protection level is set. Actual level will change when sufficient disk space is available.
.1.3.6.1.4.1.232.0.136006037
Physical Store Contains Stale or Foreign Volume Information.
.1.3.6.1.4.1.232.0.136006038
Controller Resynchronization or Reboot Occurred. Context Error
.1.3.6.1.4.1.232.0.13600768
Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has failed in communicating with the Cabinet (Rack) Bus Interface Controller.
.1.3.6.1.4.1.232.0.13600769
Severity: Critical -- failure or failure imminent. The physical disk drive identified by the device field has been rendered inoperable. <UL><LI>If the flags.quorum_disk flag is nonzero, the physical disk drive is the Storage System Quorum disk identified in the quorum_sequence field. <LI>If the flags.inq_state flag is nonzero, the content of the inq_data and capacity fields is valid. <LI>If the rss_flags.member_abnormal flag is nonzero, the content of the member_state field is valid. </UL>The rack_num field will not be valid until a future release. <P> The reason_code field contains a code giving the reason the physical disk drive has been rendered inoperable: <UL><LI>0x001 = CS IO failure <LI>0x002 = Scrubber IO failure <LI>0x003 = Attempt to set CBIT on normal drive <LI>0x004 = Attempt to set CBIT on merging drive <LI>0x100 = The Target Discovery Service Descriptor retry count has been exceeded <LI>0x101 = Inoperable for Bad Block Replacement <LI>0x102 = The soft error count has been exceeded <LI>0x103 = The number of exchange timeouts permitted was exceeded <LI>0x104 = Communication with drive has failed an excessive number of times <LI>0x105 = The number of retries has been exceeded <LI>0x106 = Medium/Hardware Errors encountered on this physical disk drive <LI>0x107 = The number of Directed LIP's has surpassed the threshold <LI>0x200 = Smart event from a physical disk drive not in Storage System <LI>0x201 = Smart event from a physical disk drive not a Volume <LI>0x202 = Smart event from a physical disk drive not a RSS <LI>0x203 = Failure predicted from physical disk drive <LI>0x204 = Can't read from physical disk drive from the poll <LI>0x205 = Failure predicted from physical disk drive while deleting Disk Group <LI>0x206 = physical disk drive forced inoperative from maintenance command for temporary POID <LI>0x207 = physical disk drive forced inoperative from maintenance command for POID <LI>0x208 = Bad block recovery failed or can't read FPAB <LI>0x209 = Failure to remove volume from Storage System <LI>0x20A = Failure to update metadata </UL>
.1.3.6.1.4.1.232.0.13600770
Severity: Warning -- not failed but attention recommended or required. A physical disk drive will not be used because the maximum number of physical disk drives already exist in the current Storage System. The affected physical disk drive is identified in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The location of the physical disk drive is contained in the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the reason_code, flags, rss_flags, inq_data, quorum_sequence, capacity, and member_state fields is undefined.
.1.3.6.1.4.1.232.0.13600771
Severity: Normal -- informational in nature. A HSV110 controller has begun booting. That controller is identified in the node_name field. Note that in this case the content of the scell_tag field is undefined.
.1.3.6.1.4.1.232.0.13600772
Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has finished the process of bringing the Storage System, identified in the scell_tag field, online.
.1.3.6.1.4.1.232.0.13600773
Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has been joined into the Storage System.
.1.3.6.1.4.1.232.0.13600774
Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has been ousted from the Storage System identified in the scell_tag field.
.1.3.6.1.4.1.232.0.13600775
Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field is now the Storage System, identified in the scell_tag field, master.
.1.3.6.1.4.1.232.0.13600776
Severity: Normal -- informational in nature. The HSV110 controller identified in the node_name field has been brought into the Storage System identified in the scell_tag field.
.1.3.6.1.4.1.232.0.136008001
Invalid Operation
.1.3.6.1.4.1.232.0.136008002
Storage system already created
.1.3.6.1.4.1.232.0.136008003
Controller already part of storage system configuration
.1.3.6.1.4.1.232.0.136008004
Physical Store Count Below Minimum
.1.3.6.1.4.1.232.0.136008005
Controller not part of storage system configuration
.1.3.6.1.4.1.232.0.136008006
Failed to uninitialize storage system
.1.3.6.1.4.1.232.0.136008007
Storage system File Open Error
.1.3.6.1.4.1.232.0.136008008
Storage system File Write Error
.1.3.6.1.4.1.232.0.136008009
Storage system File Read Error
.1.3.6.1.4.1.232.0.136008010
Name too long
.1.3.6.1.4.1.232.0.136008011
No String Error
.1.3.6.1.4.1.232.0.136008012
No MLD Handle Found
.1.3.6.1.4.1.232.0.136008013
No Controllers Found
.1.3.6.1.4.1.232.0.136008014
Controller Not Found On Loop
.1.3.6.1.4.1.232.0.136008015
No Disk Groups Found
.1.3.6.1.4.1.232.0.136008016
No Volumes Found
.1.3.6.1.4.1.232.0.136008017
No Physical Stores Found
.1.3.6.1.4.1.232.0.136008018
No Vdisks Found
.1.3.6.1.4.1.232.0.136008019
No Hosts Found
.1.3.6.1.4.1.232.0.136008020
Name already exists
.1.3.6.1.4.1.232.0.136008021
Folder is not empty
.1.3.6.1.4.1.232.0.136008022
Spares goal could not be met
.1.3.6.1.4.1.232.0.136008023
Storage system object found
.1.3.6.1.4.1.232.0.136008024
Storage system object not found
.1.3.6.1.4.1.232.0.136008025
New Physical Store Detected But Not Found In Physical Store List
.1.3.6.1.4.1.232.0.136008026
MldManager Handle is NULL
.1.3.6.1.4.1.232.0.136008027
NscMngrInterface Handle is NULL
.1.3.6.1.4.1.232.0.136008028
ScLockMngr Handle is NULL
.1.3.6.1.4.1.232.0.136008029
Storage system initialization failed
.1.3.6.1.4.1.232.0.136008030
MldMngr, NscMngrInterfaceMngr, or ScLockMngr Handle is NULL
.1.3.6.1.4.1.232.0.136008031
Storage system initialization failed
.1.3.6.1.4.1.232.0.136008032
Storage system discovery failed
.1.3.6.1.4.1.232.0.136008033
Storage system already uninitialized or does not exist
.1.3.6.1.4.1.232.0.136008034
Get Total Storage Failed
.1.3.6.1.4.1.232.0.136008035
Storage system is uninitialized
.1.3.6.1.4.1.232.0.136008036
Get Total Storage Available Failed
.1.3.6.1.4.1.232.0.136008037
Get Total Storage Occupied Failed
.1.3.6.1.4.1.232.0.136008038
Get Total Storage Free Failed
.1.3.6.1.4.1.232.0.136008039
Get Disk Group Failed
.1.3.6.1.4.1.232.0.136008040
Get Disk Group List Failed
.1.3.6.1.4.1.232.0.136008041
Get Disk Group Count Failed
.1.3.6.1.4.1.232.0.136008042
Create Volume Failed
.1.3.6.1.4.1.232.0.136008043
Get Volume Failed
.1.3.6.1.4.1.232.0.136008044
Get Volumes Failed
.1.3.6.1.4.1.232.0.136008045
Get Volumes Count Failed
.1.3.6.1.4.1.232.0.136008046
Get Vdisk Failed
.1.3.6.1.4.1.232.0.136008047
Get Vdisk List Failed
.1.3.6.1.4.1.232.0.136008048
Get Physical Store Failed
.1.3.6.1.4.1.232.0.136008049
Get Physical Stores Failed
.1.3.6.1.4.1.232.0.136008050
Get Physical Stores Count Failed
.1.3.6.1.4.1.232.0.136008051
Create Vdisk Failed
.1.3.6.1.4.1.232.0.136008052
Delete Vdisk Failed
.1.3.6.1.4.1.232.0.136008053
Get Device Addition Policy Failed
.1.3.6.1.4.1.232.0.136008054
Get Spares Current Failed
.1.3.6.1.4.1.232.0.136008055
Get Spares Goal Failed
.1.3.6.1.4.1.232.0.136008056
Get storage system events failed
.1.3.6.1.4.1.232.0.136008057
Get Volume Replacement Delay Failed
.1.3.6.1.4.1.232.0.136008058
Set Device Addition Policy Failed
.1.3.6.1.4.1.232.0.136008059
Set Spares Goal Failed
.1.3.6.1.4.1.232.0.136008060
Set Volume Replacement Delay Failed
.1.3.6.1.4.1.232.0.136008061
Create controller Failed
.1.3.6.1.4.1.232.0.136008062
Update controller Failed
.1.3.6.1.4.1.232.0.136008063
Create Host Failed
.1.3.6.1.4.1.232.0.136008064
Discard Host Failed
.1.3.6.1.4.1.232.0.136008065
Get Host Failed
.1.3.6.1.4.1.232.0.136008066
Get Host List Failed
.1.3.6.1.4.1.232.0.136008067
Get Host Count Failed
.1.3.6.1.4.1.232.0.136008068
Get Presented Unit List Failed
.1.3.6.1.4.1.232.0.136008069
Get Presented Unit Count Failed
.1.3.6.1.4.1.232.0.136008070
Free View Failed
.1.3.6.1.4.1.232.0.136008071
Storage system shutdown Failed
.1.3.6.1.4.1.232.0.136008073
Get Derived Unit List Failed
.1.3.6.1.4.1.232.0.136008074
Get Derived Unit Count Failed
.1.3.6.1.4.1.232.0.136008075
Get Vdisk list failed
.1.3.6.1.4.1.232.0.136008076
Get Vdisk count failed
.1.3.6.1.4.1.232.0.136008077
Error while building Vdisk root view
.1.3.6.1.4.1.232.0.136008078
Error while building host root view
.1.3.6.1.4.1.232.0.136008079
Error while building disk group root view
.1.3.6.1.4.1.232.0.136008080
Error while building hardware root view
.1.3.6.1.4.1.232.0.136008081
Specified time format is incorrect
.1.3.6.1.4.1.232.0.136008082
Error creating/opening time synchronization file.
.1.3.6.1.4.1.232.0.136008083
NSCList reordered.
.1.3.6.1.4.1.232.0.136008084
NscList mutex Get error
.1.3.6.1.4.1.232.0.136008085
Storage System is managed by another agent
.1.3.6.1.4.1.232.0.136008086
Memory allocation failure
.1.3.6.1.4.1.232.0.136008087
Failed to obtain list of DR Groups
.1.3.6.1.4.1.232.0.136008088
Failed to obtain count of DR Groups
.1.3.6.1.4.1.232.0.136008089
Failed to build DR Group view
.1.3.6.1.4.1.232.0.136008090
No Devices found on Controller Back End Loops
.1.3.6.1.4.1.232.0.136009001
Vdisk File Open Error
.1.3.6.1.4.1.232.0.136009002
Vdisk File Write Error
.1.3.6.1.4.1.232.0.136009003
Vdisk File Read Error
.1.3.6.1.4.1.232.0.136009004
Vdisk name too long
.1.3.6.1.4.1.232.0.136009005
Vdisk No String Error
.1.3.6.1.4.1.232.0.136009006
Vdisk No Object Error
.1.3.6.1.4.1.232.0.136009007
Vdisk still exists
.1.3.6.1.4.1.232.0.136009008
Vdisk Invalid Value
.1.3.6.1.4.1.232.0.136009009
An outstanding command is still in progress for the Vdisk
.1.3.6.1.4.1.232.0.136009010
Requested Vdisk size exceeds the available size
.1.3.6.1.4.1.232.0.136009011
Vdisk size may be expanded but not reduced
.1.3.6.1.4.1.232.0.136009012
Operation on a fast Vdisk deletion completed
.1.3.6.1.4.1.232.0.136009013
Operation on a fast Vdisk creation completed
.1.3.6.1.4.1.232.0.136009014
Operation on a fast Vdisk size expansion completed
.1.3.6.1.4.1.232.0.136009015
Vdisk cache data lost error
.1.3.6.1.4.1.232.0.136009016
Vdisk data lost error resolved
.1.3.6.1.4.1.232.0.136009017
Operation rejected - The Vdisk has a sharing relationship with another object
.1.3.6.1.4.1.232.0.136009018
Operation on this Vdisk was rejected due to its degraded condition
.1.3.6.1.4.1.232.0.136009019
Operation on this Vdisk can only be performed if it is presented to a host
.1.3.6.1.4.1.232.0.136009020
Cache policies cannot be modified if Vdisk is presented to a host
.1.3.6.1.4.1.232.0.136009021
Allowed property changes successful. (Cache policy changes not allowed while Vdisk is presented to a host.)
.1.3.6.1.4.1.232.0.136009022
Requested redundancy type cannot be implemented with the current disk group condition.
.1.3.6.1.4.1.232.0.136009023
Your Vdisk was created but cannot be presented at this time. It can be presented when it is fully allocated.
.1.3.6.1.4.1.232.0.136009025
Vdisk device data lost error
.1.3.6.1.4.1.232.0.136009026
The most significant hex character in a World Wide LUN Name must be a 6.
.1.3.6.1.4.1.232.0.136009027
Virtual disk cache and inoperative data lost error
.1.3.6.1.4.1.232.0.136009028
Virtual disk inoperative data lost error
.1.3.6.1.4.1.232.0.136009029
Virtual disk condition failed because of an inoperative data lost error.
.1.3.6.1.4.1.232.0.136009030
Vdisk is a snapshot. The following properties cannot be changed: Preferred Path, Requested Size, Write-Back Cache Policy.
.1.3.6.1.4.1.232.0.136009031
The World Wide LUN Name cannot be changed for a presented Vdisk Active member or snapshot.
.1.3.6.1.4.1.232.0.136009032
Unknown property, request rejected
.1.3.6.1.4.1.232.0.136009033
This Vdisk was deleted as the indirect result of another user command.
.1.3.6.1.4.1.232.0.136009034
The requested allocation policy cannot be satisfied. A different allocation policy is already in use by another snapshot in the same family.
.1.3.6.1.4.1.232.0.136009035
The deletion of this Vdisk cannot take place. The original Vdisk that this is being snapcloned from is in a VRaid1 Meltdown state which must first be resolved.
.1.3.6.1.4.1.232.0.136009036
Synchronous creation of virtual disk has been aborted due to an internal error. Switching to asynchronous mode to complete the virtual disk creation.
.1.3.6.1.4.1.232.0.136010001
Storage Object Broker Ready
.1.3.6.1.4.1.232.0.136010004
Storage system is not initialized
.1.3.6.1.4.1.232.0.136010006
SOB Memory Allocation Failure
.1.3.6.1.4.1.232.0.136010010
Your initialized system must have at least one disk group
.1.3.6.1.4.1.232.0.136010011
Cannot talk to all available controllers
.1.3.6.1.4.1.232.0.136010012
Command rejected - Folder is not empty
.1.3.6.1.4.1.232.0.136010013
Command rejected - Vdisk(s) or a data replication log are contained in this disk group
.1.3.6.1.4.1.232.0.136010014
Command rejected - Vdisk(s) are presented to this host
.1.3.6.1.4.1.232.0.136010015
Command rejected - This Vdisk has a sharing relationship with another object
.1.3.6.1.4.1.232.0.136010017
Command rejected - Number of disk groups will exceed the maximum allowable number
.1.3.6.1.4.1.232.0.136010018
Cannot access the password file
.1.3.6.1.4.1.232.0.136010019
Enterprise Login - Complete
.1.3.6.1.4.1.232.0.136010020
Command rejected - Disks in the group would go below the minimum required number.
.1.3.6.1.4.1.232.0.136010021
Rediscovery of controllers - Complete
.1.3.6.1.4.1.232.0.136010022
Unable to establish communication with controller, check all connections.
.1.3.6.1.4.1.232.0.136010023
Disk Group Data Lost Error Resolution Sequence 3 - Disk group resolved to normal
.1.3.6.1.4.1.232.0.136010024
Disk Group Data Lost Error Resolution Sequence 1 - Failed Vdisks marked for deletion
.1.3.6.1.4.1.232.0.136010025
Disk Group Data Lost Error Resolution Sequence 2 - Failed Vdisks deleted
.1.3.6.1.4.1.232.0.136010026
Disk Group Data Lost Error Resolution Sequence 3 - Disk group deleted
.1.3.6.1.4.1.232.0.136010027
Creating the Vdisk would exceed the maximum allowable Vdisk count
.1.3.6.1.4.1.232.0.136010028
Volume insufficient resources
.1.3.6.1.4.1.232.0.136010029
Process mutex is locked
.1.3.6.1.4.1.232.0.136010030
Invalid URL request type
.1.3.6.1.4.1.232.0.136010031
Invalid URL object type
.1.3.6.1.4.1.232.0.136010035
The snapshot/Snapclone license cannot be validated. Either the license key has not been entered, or there is a system communication failure.
.1.3.6.1.4.1.232.0.136010036
A data replication license cannot be validated. Either the license key has not been entered, or there is a system communication failure.
.1.3.6.1.4.1.232.0.136010037
Object name should not be empty or exceed its maximum length
.1.3.6.1.4.1.232.0.136010038
Object comments exceeds maximum length
.1.3.6.1.4.1.232.0.136010039
Vdisk does not meet the requirements to be part of a DR group.
.1.3.6.1.4.1.232.0.136010040
The Eva selected as the Destination for the DR group is invalid. Either it has a DR relationship with another EVA or it is not the same EVA that the source EVA presently has a DR relationship with.
.1.3.6.1.4.1.232.0.136010041
Cannot group the specified disk device because the disk is already in a disk group.
.1.3.6.1.4.1.232.0.136010042
Cannot ungroup the specified disk device because the disk is not grouped.
.1.3.6.1.4.1.232.0.136010043
Object ID provided, or object type, is invalid for the requested operation.
.1.3.6.1.4.1.232.0.136010044
Specified remote disk group does not exist.
.1.3.6.1.4.1.232.0.13601024
Severity: Undetermined -- more information needed to determine severity. HSV110 controller operation was terminated due to an unrecoverable event detected by either software or hardware or due to an action initiated via the Storage System Management Interface.
.1.3.6.1.4.1.232.0.13601025
Severity: Undetermined -- more information needed to determine severity. An HSV110 controller has sent a last gasp message prior to terminating operation. The terminated HSV110 controller is identified in the lter.terminating_ctrlr field. The lter.termination_event.u.value field contains the termination cause (i.e., termination code). The lter.termination_event.termination_location field contains the termination location. The lter.termination_time field contains the termination date and time. The lter.seq field contains the index of the HSV110 controller's Last Termination Event Array element assigned to the termination event. The lter.sw_version, lter.baselevel_id, and lter.ctrlr_model_id fields identify the software level and controller model information. The lter.uptime field contains a value that represents the number of seconds the HSV110 controller has executed functional code since its first power up. Note that the reporting_ctrlr header field identifies the HSV110 controller that received the last gasp message. All other header fields reflect information supplied by the terminating controller.
.1.3.6.1.4.1.232.0.13601026
Severity: Critical -- failure or failure imminent. A machine check occurred while a termination event was being processed. The post-termination operation being performed at the time the event occurred can be derived from the lter.reuea_index field. Note: The lteihd and lter fields may not describe the event that caused the HSV110 controller to terminate operation depending on how far termination processing got before the machine check occurred.
.1.3.6.1.4.1.232.0.13601027
Severity: Critical -- failure or failure imminent. An unexpected event occurred while a termination event was being processed. The value contained in the uei.type field describes the event as follows: <UL><LI>0 = Unrecognized Unexpected Event code. <LI>1 = Power failure before initialization could complete. <LI>2 = Recursive termination before initialization could complete. <LI>3 = Terminated during the first part post-termination preparation. <LI>4 = Terminated during the load of the G3 Glue registers. <LI>5 = Terminated during the second part post-termination preparation. <LI>6 = Terminated during event report block load. <LI>7 = Terminated during initialization of all hardware components and software data structures in preparation for restart. <LI>8 = Terminated during execution of an unrecognized post-termination operation (premature). <LI>9 = Power failure during execution of a post-termination operation. <LI>A = No good entries found in Termination Event Array. (Note that this condition is expected following the first boot of a newly manufactured HSV110 controller. In that case this event can be safely ignored; no action is necessary.) <LI>B = The EDC of one or more Termination Event Array entries is bad. <LI>C = Termination Event Array entry control block revision is different. <LI>D = Termination Event Array entry information block revision is different. <LI>E = Termination Event Array entry up time value is greater than the system's up time value. <LI>F = Termination Event Array entry up time value is less than the previous entry's up time value. <LI>10= Termination Event Array entry sequence number value is less than the previous entry's sequence number value. <LI>11= Detected an unrecognized dump/restart control code. <LI>12= Failed to terminate the entity dump loop. <LI>13= Unexpected dump entity size. <LI>14= Unexpected Event Log Packet processing stage code. <LI>15= Number of Termination Parameters supplied not equal to maximum allowed as required. </UL><P> The post-termination operation being performed at the time the unexpected event occurred is contained in the uei.pto field. Note: The lteihd and lter fields may not describe the event that caused the HSV110 controller to terminate operation depending on how far termination processing got before the unexpected event occurred.
.1.3.6.1.4.1.232.0.13601028
Severity: Normal -- informational in nature. The Storage System Event Log validation completed successfully. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi structure, and the minfo.scelmi structure show the validated state of the Storage System Event Log. The meaning of the status value contained in the cinfo.scelcbi.status field is as follows: <UL><LI>0 = No problems found. </UL><P> Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601029
Severity: Normal -- informational in nature. The Storage System Event Log validation failed. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi structure, and the minfo.scelmi structure show the state of the Storage System Event Log at the time of the failure. The content and state of the Storage System Event Log have been initialized to their initial operational settings. The meaning of the status value contained in the cinfo.scelcbi.status field is as follows: <UL><LI>1 = Cookie value is not as expected. <LI>2 = Event data overflows the buffer. <LI>3 = Event data size is not a multiple of 4 bytes, is less than the minimum, or is greater than the maximum. <LI>4 = Event Information Packet type is greater than the maximum. <LI>5 = Event information size is not a multiple of 4 bytes, is less than the minimum, is greater than the maximum, doesn't match the Event Information Packet type size, or when combined with the entry header size doesn't equal the entry size. <LI>6 = Event code is zero. <LI>7 = Event is out of sequence. <LI>8 = Dead space area at the end of a partially packed buffer contains a nonzero value. <LI>9 = An event data block containing a nonzero value was found after end of event data was detected. <LI>A = Sequence number reset flag not set as expected. <LI>B = The event log contains no entries. <LI>C = Event data block read failed during maintenance verification. <LI>D = Event data block read failed during maintenance completion. <LI>E = Event data block erase failed during maintenance completion. <LI>F = Control block read failed during maintenance verification. <LI>17= The event log was destroyed and prepared for re-initialization. </UL><P> Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601030
Severity: Critical -- failure or failure imminent. Event reports were lost due to an insufficient supply of Event Log Packets on the HSV110 controller that is the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601031
Severity: Critical -- failure or failure imminent. Event reports were lost due to an insufficient supply of Event Log Packets on the HSV110 controller that is not the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601032
Severity: Normal -- informational in nature. The Storage System Termination Event Log has become inaccessible. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the current state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: <UL><LI>F = Control block read failed during maintenance verification. <LI>10= Control block write failed during maintenance verification. <LI>11= Event data block write failed during maintenance update. <LI>12= Control block write failed during maintenance completion. <LI>13= Storage System Termination Event Log related send was unsuccessful or the master found that the Storage System Termination Event Log is inaccessible. <LI>16= Event data block read failed during retrieval request. </UL><P> Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601033
Severity: Normal -- informational in nature. The Storage System Termination Event Log validation completed successfully. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the validated state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: <UL><LI>0 = No problems found. </UL><P> Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601034
Severity: Normal -- informational in nature. The Storage System Termination Event Log validation failed. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the state of the Storage System Termination Event Log at the time of the failure. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: <UL><LI>F = Control block read failed during maintenance verification. <LI>10= Control block write failed during maintenance verification. <LI>11= Event data block write failed during maintenance update. <LI>12= Control block write failed during maintenance completion. <LI>13= Storage System Termination Event Log related send was unsuccessful or the master found that the Storage System Termination Event Log is inaccessible. <LI>16= Event data block read failed during retrieval request. <LI>17= The log was destroyed and prepared for re-initialization. </UL><P> Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601035
Severity: Normal -- informational in nature. The Storage System Termination Event Log has been updated with the termination event information obtained from the HSV110 controller that is not the Storage System Master. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the updated state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: <UL><LI>0 = No problems found. </UL><P> Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601036
Severity: Critical -- failure or failure imminent. The Fault Manager on the Storage System Master received an invalid Event Information Packet from the remote Fault Manager. The header information from the invalid Event Information Packet is contained in the ainfo.remote_event field. Note: The content of the ainfo.quiesce_type field, ainfo.events_not_reported field, cinfo.scelcbi structure, cinfo.sctelcbi structure, minfo.scelmi structure, and minfo.sctelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601037
Severity: Normal -- informational in nature. The Fault Manager operation was made quiescent. If the ainfo.quiesce_type field is equal to 0, the operation was performed on both HSV110 controllers. If the ainfo.quiesce_type field is equal to 1, the operation was performed only on the HSV110 controller that is not the Storage System Master. Note: The content of the ainfo.events_not_reported field, cinfo.scelcbi structure, cinfo.sctelcbi structure, minfo.scelmi structure, and minfo.sctelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601038
Severity: Undetermined -- more information needed to determine severity. An HSV110 controller sent a last gasp message prior to terminating operation with an indication that the HSV110 controller identified in the lter.terminating_ctrlr field should also terminate operation.
.1.3.6.1.4.1.232.0.13601039
Severity: Normal -- informational in nature. This HSV110 controller sent its termination event information to the HSV110 controller that is the Storage System Master. The content of the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the updated state of the Storage System Termination Event Log. The meaning of the status value contained in the cinfo.sctelcbi.status field is as follows: <UL><LI>0 = No problems found. </UL><P> Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601040
Severity: Critical -- failure or failure imminent. Event reports were lost due to an insufficient supply of ISR Event Log Packets on the HSV110 controller that is the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.
.1.3.6.1.4.1.232.0.13601041
Severity: Critical -- failure or failure imminent. Event reports were lost due to an insufficient supply of ISR Event Log Packets on the HSV110 controller that is not the Storage System Master. The ainfo.events_not_reported field shows the number of event reports lost. Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.
.1.3.6.1.4.1.232.0.136011001
Agent startup complete
.1.3.6.1.4.1.232.0.136011002
Agent shutdown complete
.1.3.6.1.4.1.232.0.136011003
Insufficient memory to create a new object, Heap may be full!
.1.3.6.1.4.1.232.0.136011004
Agent Startup Failed
.1.3.6.1.4.1.232.0.136012001
Nsc Manager Interface No controllers Found
.1.3.6.1.4.1.232.0.136012002
Nsc Manager Interface Index Out Of Range
.1.3.6.1.4.1.232.0.136012003
Unable to process command at this time. Retry the command or check all connections.
.1.3.6.1.4.1.232.0.136012004
Nsc Manager Interface Initialization Complete
.1.3.6.1.4.1.232.0.136012005
Nsc Manager Interface Initialization Failed
.1.3.6.1.4.1.232.0.136012008
No Disk Groups Available For Access
.1.3.6.1.4.1.232.0.136013002
Notification Mngr Online
.1.3.6.1.4.1.232.0.136013003
Notification Mngr Offline
.1.3.6.1.4.1.232.0.136013004
NM Startup Complete
.1.3.6.1.4.1.232.0.136013007
Notification Failed
.1.3.6.1.4.1.232.0.136013009
Notification Failed - Network Error
.1.3.6.1.4.1.232.0.136013012
NM Prev Failed Notification Successfully Notified
.1.3.6.1.4.1.232.0.136013015
NM SNMP Packet Failed
.1.3.6.1.4.1.232.0.136013017
NM Memory Allocation Error
.1.3.6.1.4.1.232.0.136013018
NM StorageCell handle is NULL
.1.3.6.1.4.1.232.0.136013019
NM User defined event state file is empty
.1.3.6.1.4.1.232.0.136013020
NM Notification Failed - Notification Matrix is NULL
.1.3.6.1.4.1.232.0.136014001
View Already Exists
.1.3.6.1.4.1.232.0.136014002
View Is Not Set
.1.3.6.1.4.1.232.0.136014003
No View Object(s) Found
.1.3.6.1.4.1.232.0.136014004
View Index Is Out Of Range
.1.3.6.1.4.1.232.0.136014005
View Object - Invalid Object Condition
.1.3.6.1.4.1.232.0.136014006
View Object - Invalid Object Type
.1.3.6.1.4.1.232.0.136014007
View List Pointer is NULL
.1.3.6.1.4.1.232.0.136014008
View Object Pointer is NULL
.1.3.6.1.4.1.232.0.136014009
Building View List Object - Complete
.1.3.6.1.4.1.232.0.136014010
Building View List Object - Failed
.1.3.6.1.4.1.232.0.136014012
View Find by UID Failed
.1.3.6.1.4.1.232.0.136014013
View Find by Type Failed
.1.3.6.1.4.1.232.0.136014017
View Find by Type by Name Failed
.1.3.6.1.4.1.232.0.136015001
Tree View Symbol Not Found
.1.3.6.1.4.1.232.0.136015002
Tree View Id Symbol Not Found
.1.3.6.1.4.1.232.0.136015003
Tree Cursor Symbol Not Found
.1.3.6.1.4.1.232.0.136015004
Tree Cursor Id Symbol Not Found
.1.3.6.1.4.1.232.0.136015005
Tree Sibling Symbol Not Found
.1.3.6.1.4.1.232.0.136015006
Tree Total Children Symbol Not Found
.1.3.6.1.4.1.232.0.136015007
Tree Expansion Symbol Not Found
.1.3.6.1.4.1.232.0.136015008
Tree Contraction Symbol Not Found
.1.3.6.1.4.1.232.0.136015009
Tree Invalid Descriptor String
.1.3.6.1.4.1.232.0.13601536
Severity: Critical -- failure or failure imminent. A physical disk drive has reported that it has exceeded its failure prediction threshold. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. The sense data obtained from the physical disk drive as a result of the failure prediction threshold exceeded error is contained in the error field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601537
Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon. The failure_cause field contains the internal routing value as follows: <UL><LI>1 - Excessive exchange timeouts on loop <LI>2 - Excessive link errors on loop <LI>3 - Exhausted Link Down retries on loop with signal <LI>4 - Exhausted Link Down retries on loop with loss of signal <LI>5 - Excessive link inits on loop without completing device discovery </UL>
.1.3.6.1.4.1.232.0.13601538
Severity: Normal -- informational in nature. A physical disk drive has reported a check condition error. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. The sense data obtained from the physical disk drive as a result of the check condition error is contained in the error field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601539
Severity: Warning -- not failed but attention recommended or required. An exchange sent to a physical disk drive or another HSV110 controller via the mirror port or a Fibre Channel port has timed out. The identity of the intended recipient is contained in the device field. The Fibre Channel port over which the frame was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the frame was sent is contained in the port field. The arbitrated loop physical address of the intended recipient is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the intended recipient is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The number of timeouts detected is contained in the num_times field. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601540
Severity: Warning -- not failed but attention recommended or required. Work was unexpectedly sent to this HSV110 controller by a physical disk drive or another HSV110 controller. This HSV110 controller did not originate the work. The identity of the sender is contained in the device field. The Fibre Channel port over which the unexpected work was received is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the unexpected work was received is contained in the port field. The arbitrated loop physical address of the sender is contained in the al_pa field. The location of the sender is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The hdr_cdb field contains the command descriptor block and Fibre Channel header information associated with the unexpected work.
.1.3.6.1.4.1.232.0.13601541
Severity: Warning -- not failed but attention recommended or required. Work has been sent to a physical disk drive or another HSV110 controller via the mirror port but it did not respond. The identity of the intended target is contained in the device field. The Fibre Channel port over which the work was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which the work was sent is contained in the port field. The arbitrated loop physical address of the intended target is contained in the al_pa field. The location of the intended target is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the intended target is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601543
Severity: Warning -- not failed but attention recommended or required. A Target Discovery Service Descriptor exchange sent to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601544
Severity: Normal -- informational in nature. An excessive number of link errors were detected on a HSV110 controller's Fibre Channel port. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. This is an informational event triggered by the occurrence of an excessive number of Tachyon chip link status errors detected within a particular link status error type. The number of occurrences of each link status error type is contained in a separate type-specific field (e.g., loss_of_signal, bad_rx_char, etc.). The HSV110 controller checks each of its Fibre Channel port's for excessive link status errors periodically.
.1.3.6.1.4.1.232.0.13601545
Severity: Critical -- failure or failure imminent. A physical disk drive has reported numerous failure prediction threshold exceeded errors. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The num_times field is the number of failure prediction threshold exceeded errors reported by the physical disk drive in the previous minute. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601546
Severity: Normal -- informational in nature. A physical disk drive has reported numerous check condition errors. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The num_times field is the number of check condition errors reported by the physical disk drive in the previous minute. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601547
Severity: Warning -- not failed but attention recommended or required. A non-data exchange sent to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601548
Severity: Normal -- informational in nature. A loop switch has been detected on a Fibre Channel port. The identity of the Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number is contained in the port field. Note that in this case the content of the device, al_pa, rack_num, dencl_num, bay, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601549
Severity: Normal -- informational in nature. The location of a physical disk drive previously reported as unknown is now known. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is contained in the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of fed_class, al_pa and num_times fields are undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601550
Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit requested a code update but the code update could not be found, so the update was not performed. The identity of the affected Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, bay, fed_class and num_times field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601551
Severity: Critical -- failure or failure imminent. The Drive Enclosure Environmental Monitoring Unit is able to communicate with a physical disk drive but this HSV110 controller is unable to communicate with that physical disk drive on the Fibre Channel bus. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is contained in the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the al_pa, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601552
Severity: Undetermined -- more information needed to determine severity. A HSV110 controller is unable to communicate with this Drive Enclosure Environmental Monitoring Unit. The Drive Enclosure Environmental Monitoring Unit identified in the device field has stopped communicating with the HSV110 controller. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the bay, al_pa, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601554
Severity: Normal -- informational in nature. The retry count for a task assigned to a Drive Enclosure Environmental Monitoring Unit has been exhausted. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The peb array contains the task list that was intended to be sent to the Drive Enclosure Environmental Monitoring Unit. The peq_frz_prod_index field contains the task that was being retried. The peq_prod_index field contains the drive enclosure where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit is located. The peq_cons_index field identifies the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) used to communicate with the physical disk drive that was used to communicate with the Drive Enclosure Environmental Monitoring Unit. The failure_cause field contains the bay where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit.
.1.3.6.1.4.1.232.0.13601555
Severity: Normal -- informational in nature. A Drive Enclosure Environmental Monitoring Unit is able to communicate with this HSV110 controller. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the bay, fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601556
Severity: Critical -- failure or failure imminent. There are too many drive enclosures attached to a Fibre Channel port. The Fibre Channel port with too many drive enclosures attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of the identified in the cerp_id field. The device, missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601557
Severity: Critical -- failure or failure imminent. The cable connected to the I/O module is attached to the wrong Fibre Channel port. The Fibre Channel port incorrectly attached to the HSV110 controller is contained in the cerp_id field. Note that in this case the content of the device, missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601558
Severity: Critical -- failure or failure imminent. A HSV110 controller does not have an address on the enclosure address bus. The HSV110 controller location cannot be identified. Note that in this case the content of the missing_port, missing_cerp_id, bay, fed_class, rack_num, dencl_num, al_pa, device, cerp_id, port, enclosures array and num_times fields is undefined.
.1.3.6.1.4.1.232.0.13601560
Severity: Normal -- informational in nature. A Drive Enclosure Environmental Monitoring Unit has begun updating its code. Do not power down this drive enclosure until the code update has completed. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. In addition, the device field may contain all zeroes. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that the content of the fed_class, al_pa, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601561
Severity: Normal -- informational in nature. A Drive Enclosure Environmental Monitoring Unit has completed updating its code. It is now safe to power down this drive enclosure. The identity of the Drive Enclosure Environmental Monitoring Unit is contained in the device field. The Fibre Channel port used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Drive Enclosure Environmental Monitoring Unit is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, al_pa, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601562
Severity: Critical -- failure or failure imminent. A physical disk drive has exceeded its soft error threshold. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, cdb, and sense_data fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601563
Severity: Normal -- informational in nature. A HSV110 controller now has an address on the enclosure address bus. The HSV110 controller location has been identified. The location of the HSV110 controller is contained in the rack_num and dencl_num fields. Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the bay, fed_class, al_pa, cerp_id, port, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601564
Severity: Warning -- not failed but attention recommended or required. An outbound frame targeted to a physical disk drive has timed out. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601565
Severity: Warning -- not failed but attention recommended or required. A Fibre Channel exchange to a physical disk drive has completed but is missing data. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the physical disk drive is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601566
Severity: Critical -- failure or failure imminent. A HSV110 controller has detected only one port of a Fibre Channel device. This Fibre Channel device has entered the Single Port on Fibre state which should be corrected as soon as possible. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV110 controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601567
Severity: Normal -- informational in nature. A previously reported Fibre Channel device with only one port has been corrected and redundancy has been restored. The device is no longer in the Single Port on Fibre state. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The missing_port and missing_cerp_id fields are unused. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601568
Severity: Critical -- failure or failure imminent. An unsupported Fibre Channel device has been detected. The drive has been failed to prevent possible data corruption or system instability. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601569
Severity: Normal -- informational in nature. A Fibre Channel device with the incorrect block size has been detected. The identity of the Fibre Channel device is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The arbitrated loop physical address of the Fibre Channel device is contained in the al_pa field. The missing_port and missing_cerp_id fields are unused. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601571
Severity: Normal -- informational in nature. A HSV110 controller is about to retry a failed port. The Fibre Channel port that is about to be retried is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number about to be retried is contained in the port field. Note that in this case the content of the bay, rack_num, fed_class, al_pa, dencl_num, device, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601572
Severity: Normal -- informational in nature. A HSV110 controller has successfully retried a failed port. The Fibre Channel port that has been restarted is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number that has been restarted is contained in the port field. Note that in this case the content of the bay, rack_num, fed_class, al_pa, dencl_num, device, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The missing_port and missing_cerp_id fields are unused. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601573
Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit has failed to assign a hard address to a physical disk drive on the loop. The device field contains the identity of the enclosure. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The al_pa field contains the expected AL_PA, and the num_times field contains the actual AL_PA. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the fed_class is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601574
Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit has failed to assign an address to a physical disk drive on the loop. This has occurred because another physical disk drive has already obtained this AL_PA. The device field contains the identity of the enclosure. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The al_pa field contains the AL_PA that was stolen. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601575
Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit has failed to assign address(s) to a physical disk drive on the loop. Soft addressing was detected for this enclosure. The device field contains the identity of the enclosure. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The missing_port and missing_cerp_id fields are unused. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, al_pa, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601576
Severity: Normal -- informational in nature. The retry count for an OB task assigned to a Drive Enclosure Environmental Monitoring Unit has been exhausted. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The peb array contains the task list that was intended to be sent to the Drive Enclosure Environmental Monitoring Unit. The peq_frz_prod_index field contains the task that was being retried. The peq_prod_index field contains the drive enclosure where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit is located. The peq_cons_index field identifies the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) used to communicate with the physical disk drive that was used to communicate with the Drive Enclosure Environmental Monitoring Unit. The failure_cause field contains the bay where the physical disk drive used to communicate with the Drive Enclosure Environmental Monitoring Unit.
.1.3.6.1.4.1.232.0.13601577
Severity: Normal -- informational in nature. The HSV110 controller has sent a Basic Link Service command Abort Sequence Frame. The original work is described in this event. The identity of the intended target is contained in the device field. The Fibre Channel port over which the work was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which the work was sent is contained in the port field. The arbitrated loop physical address of the intended target is contained in the al_pa field. The location of the intended target is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the intended target is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601578
Severity: Normal -- informational in nature. The HSV110 controller has sent an Extended Link Service command Reinstate Recovery Qualifier. The original work is described in this event. The identity of the intended target is contained in the device field. The Fibre Channel port over which the work was sent is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which the work was sent is contained in the port field. The arbitrated loop physical address of the intended target is contained in the al_pa field. The location of the intended target is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The Fibre Channel Exchange Descriptor class is contained in the fed_class field. The command issued to the intended target is contained in the cmd field. Note that in this case the content of the error field is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601579
Severity: Critical -- failure or failure imminent. A physical disk drive was bypassed rendering it unusable. The physical disk drive is unusable because a Drive Enclosure Environmental Monitoring Unit bypassed a drive bay or the physical disk drive left itself bypassed. The physical disk drive is not available to the HSV110 controllers and will not be displayed by the HSV element manager GUI. The physical disk drive fault led will be lit to indicate that it is unusable. The Fibre Channel port over which this condition was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port over which this condition was detected is contained in the port field. The al_pa field is invalid. The location of the physical disk drive is as indicated by the content of the rack_num, dencl_num, and bay fields. Note that the content of the rack_num field will not be valid until a future release. The bypass_reason field is used to indicate how the physical disk drive was bypassed: <UL><LI>1 = The physical disk drive left itself bypassed <LI>2 = The Drive Enclosure Environmental Monitoring Unit bypassed the drive bay </UL>The Drive Enclosure Environmental Monitoring Unit is identified in the device field. Additionally, the content of the pid, rev, and enclosures array fields is undefined in this case.
.1.3.6.1.4.1.232.0.13601580
Severity: Normal -- informational in nature. One or more media defects were detected on a physical disk drive. The affected physical disk drive is identified in the device field. The Fibre Channel port over which the media defect(s) was detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the media defect(s) was detected is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The Logical Block Address of each media defect is contained in a separate entry of the hdr_cdb array. Only nonzero values in the hdr_cdb array entries are valid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601581
Severity: Normal -- informational in nature. An HSV110 controller issued a directed LIP to an arbitrated loop physical address. The Fibre Channel port over which the directed LIP was issued is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the directed LIP was issued is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field.
.1.3.6.1.4.1.232.0.13601582
Severity: Normal -- informational in nature. An HSV110 controller has detected Loop Receiver Failures. The Fibre Channel port over which the Loop Receiver Failures were detected is identified in the cerp_id field. The HSV110 controller internal Fibre Channel port number over which the Loop Receiver Failures were detected is contained in the port field. The counts and the AL_PAs of the Loop Receiver Failures are contained in a separate entry of the hdr_cdb array. Only nonzero values in the hdr_cdb array entries are valid. The affected HSV110 controller is identified in the device field. Note that in this case the content of the al_pa, dencl_num, bay, and rack_num fields are undefined.
.1.3.6.1.4.1.232.0.13601584
Severity: Critical -- failure or failure imminent. A HSV110 controller has detected only one port of all Fibre Channel devices in an enclosure. These Fibre Channel devices have entered the Single Port on Fibre state which should be corrected as soon as possible. The identity of the Fibre Channel device enclosure is contained in the device field. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV110 controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field. The al_pa and bay fields are invalid. The location of the Fibre Channel enclosure is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601585
Severity: Normal -- informational in nature. A previously reported Fibre Channel device enclosure with only one port has been corrected and redundancy has been restored. The devices in the enclosure are no longer in the Single Port on Fibre state. The identity of the Fibre Channel device enclosure is contained in the device field. The Fibre Channel port used to communicate with the Fibre Channel device enclosure is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel device is contained in the port field. The al_pa, bay, missing_port, and missing_cerp_id fields are invalid. The location of the Fibre Channel device is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601586
Severity: Critical -- failure or failure imminent. A HSV110 controller has detected only one port of all Fibre Channel devices on a loop. These Fibre Channel devices have entered the Single Port on Fibre state which should be corrected as soon as possible. The device, al_pa, dencl_num, and bay fields are all invalid. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV110 controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field.
.1.3.6.1.4.1.232.0.13601587
Severity: Normal -- informational in nature. A previously reported Fibre Channel loop with only one port has been corrected and redundancy has been restored. The devices on the loop are no longer in the Single Port on Fibre state. The device, al_pa, dencl_num, bay, missing_port, and missing_cerp_id fields are invalid. The Fibre Channel port used to communicate with the Fibre Channel devices is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the Fibre Channel devices is contained in the port field.
.1.3.6.1.4.1.232.0.13601588
Severity: Normal -- informational in nature. A HSV110 controller has been told to enable a device port, and that device port was not disabled during boot diagnostics. The Fibre Channel port that was enabled is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number enabled is contained in the port field. Note that in this case the contents of the bay, rack_num, fed_class, al_pa, dencl_num, device, enclosure array, and num_times fields are undefined. The missing_port and missing_cerp_id fields are unused.
.1.3.6.1.4.1.232.0.13601589
Severity: Critical -- failure or failure imminent. An unrecognized Fibre Channel physical disk drive firmware revision has been detected by the physical disk drive firmware load process. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The bypass_reason field is invalid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num, al_pa and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The pid field contains the SCSI Inquiry Product Identification obtained from the physical disk drive. The rev field contains the current firmware revision obtained from the physical disk drive. The new_rev field contains the latest firmware version known to the controller, or blanks if the isn't a known version. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601590
Severity: Critical -- failure or failure imminent. An unsupported Fibre Channel physical disk drive firmware revision has been detected by the physical disk drive firmware load process. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The bypass_reason field is invalid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num, al_pa and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The pid field contains the SCSI Inquiry Product Identification obtained from the physical disk drive. The rev field contains the current firmware revision obtained from the physical disk drive. The new_rev field contains the latest firmware version known to the controller, or blanks if the isn't a known version. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601591
Severity: Normal -- informational in nature. A Fibre Channel physical disk drive firmware revision has been detected by the physical disk drive firmware load process that is later than the latest known supported revision. If the location information is 0, it indicates the type of drive, not a specific drive. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The bypass_reason field is invalid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num, al_pa and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The pid field contains the SCSI Inquiry Product Identification obtained from the physical disk drive. The rev field contains the current firmware revision obtained from the physical disk drive. The new_rev field contains the latest firmware version known to the controller, or blanks if the isn't a known version. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601592
Severity: Normal -- informational in nature. A Fibre Channel physical disk drive firmware revision has been detected by the physical disk drive firmware load process that has a newer supported revision available. If the location information is 0, it indicates the type of drive, not a specific drive. The identity of the physical disk drive is contained in the device field. The Fibre Channel port used to communicate with the physical disk drive is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number used to communicate with the physical disk drive is contained in the port field. The arbitrated loop physical address of the physical disk drive is contained in the al_pa field. The bypass_reason field is invalid. The location of the physical disk drive is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num, dencl_num, and bay fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num, al_pa and bay fields is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num, dencl_num, and bay fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. The pid field contains the SCSI Inquiry Product Identification obtained from the physical disk drive. The rev field contains the current firmware revision obtained from the physical disk drive. The new_rev field contains the latest firmware version known to the controller, or blanks if the isn't a known version. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13601593
Severity: Normal -- informational in nature. The HSV110 controller bypassed a device bay in an attempt to restore operability. The identity of the bay is indicated by the rack_num, dencl_num, and bay fields. All other fields are invalid.
.1.3.6.1.4.1.232.0.13601594
Severity: Normal -- informational in nature. The HSV110 controller is attempting to recovery devices on the indicated port. All other fields are invalid.
.1.3.6.1.4.1.232.0.13601595
Severity: Normal -- informational in nature. The HSV110 controller has finished error recovery attempts on the indicated port. All other fields are invalid.
.1.3.6.1.4.1.232.0.13601596
Severity: Normal -- informational in nature. The HSV110 controller been requested to unbypass device bays on the indicated port. All other fields are invalid.
.1.3.6.1.4.1.232.0.13601597
Severity: Undetermined -- more information needed to determine severity. The HSV110 controller has detected a enclosure on the CAB bus that does not have a Fibre Channel connection. All fields except port and rack are invalid. other fields are invalid.
.1.3.6.1.4.1.232.0.13601598
Severity: Critical -- failure or failure imminent. The HSV110 controller has detected an enclosure on the Fibre Channel but is unable to communicate with the EMU on the CAB bus or the EMU is reporting an invalid enclosure number. All fields except port and rack are invalid. other fields are invalid.
.1.3.6.1.4.1.232.0.136016001
Ema Short Status - Reissue Command
.1.3.6.1.4.1.232.0.136016004
Ema Invalid Handle Set In Request Packet
.1.3.6.1.4.1.232.0.136016005
Ema No Pstore At Referenced Location
.1.3.6.1.4.1.232.0.136016008
Ema No Device Found
.1.3.6.1.4.1.232.0.136016010
Ema Could Not Find SubEnclosure in Configuration List
.1.3.6.1.4.1.232.0.136016012
Ema Non-specific error occurred
.1.3.6.1.4.1.232.0.136016013
Ema Shelf WWN Could Not Be Accessed Through A Drive
.1.3.6.1.4.1.232.0.136016014
Ema EMU Failed To Enter Primary Mode
.1.3.6.1.4.1.232.0.136016015
Ema EMU Failed To Exit Primary Mode
.1.3.6.1.4.1.232.0.136016016
Ema Downloaded File Does Not Contain Valid Fibre Channel Loader [status:1]
.1.3.6.1.4.1.232.0.136016017
Ema Downloaded File Format Is Not Recognized [status:2]
.1.3.6.1.4.1.232.0.136016018
Ema Incorrect Firmware In Downloaded File [status:3]
.1.3.6.1.4.1.232.0.136016019
Ema Downloaded Loader is Too Large [status:4]
.1.3.6.1.4.1.232.0.136016020
Ema Invalid Checksum [status:5]
.1.3.6.1.4.1.232.0.136016021
Ema Previous Offset Plus Previous Length Not Equal To Current Offset [status:6]
.1.3.6.1.4.1.232.0.136016022
Ema Downloaded Loader Terminated Incorrectly [status:7]
.1.3.6.1.4.1.232.0.136016023
Ema EMU Out Of Memory [status:8]
.1.3.6.1.4.1.232.0.136016024
Ema EMU CDB Timeout -- Download Aborted [status:9]
.1.3.6.1.4.1.232.0.136016025
Ema EMU Internal State Machine Error [status:10]
.1.3.6.1.4.1.232.0.136016026
Ema EMU Flash Erasure Failure [status:11]
.1.3.6.1.4.1.232.0.136016027
Ema EMU In Primary Mode - Cannot Download To Primary EMU [status:12]
.1.3.6.1.4.1.232.0.136016028
Ema Previous Offset Plus Previous Length Greater Than Total Size [status:13]
.1.3.6.1.4.1.232.0.136016029
Ema Current Total Size Different From Previous Total Size [status:14]
.1.3.6.1.4.1.232.0.136016030
Ema Could Not Restore Reporting Group Number. Final Download Record Error
.1.3.6.1.4.1.232.0.136016031
Ema Could Not Recovery From Invop. Invop Retries Exhausted
.1.3.6.1.4.1.232.0.136016032
Ema Requested WWN Does Not Match Enclosure WWN
.1.3.6.1.4.1.232.0.136016033
Ema EMU Enclosure Services Error Occurred. EMU May Be Unavailable or Not Installed
.1.3.6.1.4.1.232.0.136016034
Ema SCSI Error Occurred While Trying To Communicate With EMU
.1.3.6.1.4.1.232.0.136016035
Ema Could Not Open EMU Firmware File
.1.3.6.1.4.1.232.0.136016036
Ema EMU Firmware File Name Is Null
.1.3.6.1.4.1.232.0.136016037
Ema EMU Firmware Download Retries Exhausted. Manual Download May Be Required
.1.3.6.1.4.1.232.0.136016038
Ema EMU Current Firmware Version Matches Upgrade Firmware Version. No Upgrade Will Be Performed.
.1.3.6.1.4.1.232.0.136016039
Ema EMU Firmware Upgrade Success
.1.3.6.1.4.1.232.0.136016040
Ema EMU In Load State. Do Not Power Off. Reload EMU Firmware
.1.3.6.1.4.1.232.0.136017001
Drive Code Load Descriptor File Open Error
.1.3.6.1.4.1.232.0.136017002
Drive Code Load Descriptor File Parsing Error - Invalid Line
.1.3.6.1.4.1.232.0.136017003
Drive Code Load Image File Open Error,
.1.3.6.1.4.1.232.0.136017004
Drive Code Load Image File Error Getting File Size
.1.3.6.1.4.1.232.0.136017005
Drive Code Load Image File Buffer Allocation Error
.1.3.6.1.4.1.232.0.136017006
Drive Code Load Image File Read Error
.1.3.6.1.4.1.232.0.136017007
Drive Code Load Drive Firmware Update Failed
.1.3.6.1.4.1.232.0.136017008
Drive Code Load Drive Inquiry Failed
.1.3.6.1.4.1.232.0.136017009
Drive Code Load Format Command Failed
.1.3.6.1.4.1.232.0.136017012
Drive Code Load Get Physical Store Condition Failed
.1.3.6.1.4.1.232.0.136017013
Drive Code Load Get Volume Condition Failed
.1.3.6.1.4.1.232.0.136017014
Drive Code Load Drive Spin Up Error
.1.3.6.1.4.1.232.0.136017015
Drive Code Load - Complete
.1.3.6.1.4.1.232.0.136017016
Drive Code Load Disk Group Migration In Progress
.1.3.6.1.4.1.232.0.136017017
Drive Code Load Unable To Code Load Disks Part Of A Group
.1.3.6.1.4.1.232.0.13601792
Severity: Warning -- not failed but attention recommended or required. Allocation of a Virtual Disk has stalled due to insufficient space in the Disk Group caused by the failure or pulling of a physical disk drive. The tag1 field contains the identity of the Virtual Disk. The tag2 field contains the identity of the Disk Group. The values that may be found in the state field are as follows: <UL><LI>0 = Attempting to retry the allocation <LI>1 = Awaiting a leveling event (a drive needs to be inserted) </UL>
.1.3.6.1.4.1.232.0.13601793
Severity: Warning -- not failed but attention recommended or required. Expansion of a Virtual Disk has stalled due to insufficient space in the Disk Group caused by the failure or pulling of a physical disk drive. The tag1 field contains the identity of the Virtual Disk. The tag2 field contains the identity of the Disk Group. The values that may be found in the state field are as follows: <UL><LI>0 = Attempting to retry the expansion <LI>1 = Awaiting a leveling event (a drive needs to be inserted) </UL>
.1.3.6.1.4.1.232.0.13601794
Severity: Normal -- informational in nature. Leveling of capacity in a Disk Group has started. The identity of the Disk Group is contained in the tag1 field.
.1.3.6.1.4.1.232.0.13601795
Severity: Normal -- informational in nature. Leveling of capacity in a Disk Group has finished. The identity of the Disk Group is contained in the tag1 field.
.1.3.6.1.4.1.232.0.13601796
Severity: Normal -- informational in nature. A member management operation has started due to the appearance or disappearance of a physical disk drive. If available, the tag1 field contains the identity of the physical disk drive. The tag2 field contains the disk unit block in which physical disk drive resides. The values that may be found in the state field are as follows: <UL><LI>2 = Reconstructing <LI>4 = Migrating <LI>6 = Reverting </UL>
.1.3.6.1.4.1.232.0.13601797
Severity: Normal -- informational in nature. A member management operation has finished. If available, the tag1 field contains the identity of the physical disk drive. The tag2 field contains the disk unit block in which the physical disk drive resides. The values that may be found in the state field are as follows: <UL><LI>2 = Reconstructing <LI>4 = Migrating <LI>6 = Reverting </UL>The status field contains one of the following values: <UL><LI>1 = PSEGS NONE ( Reconstruction of data was successful ) <LI>2 = PSEGS RAID0 ( Could not reconstruct RAID0 data ) <LI>4 = PSEGS RAID5 ( Could not reconstruct RAID5 data ) <LI>8 = PSEGS RAID1 ( Could not reconstruct RAID1 data ) </UL>
.1.3.6.1.4.1.232.0.13601798
Severity: Normal -- informational in nature. A Disk Group has started changing its internal structure due to the appearance or disappearance of a Volume. The identity of the Disk Group is contained in the tag1 field. The values that may be found in the state field are as follows: <UL><LI>4 = Merge began <LI>8 = Split began </UL>
.1.3.6.1.4.1.232.0.13601799
Severity: Normal -- informational in nature. A Disk Group has finished changing its internal structure due to the appearance or disappearance of a volume. The identity of the Disk Group is contained in the tag1 field. The values that may be found in the state field are as follows: <UL><LI>4 = Merge completed <LI>8 = Split completed </UL>
.1.3.6.1.4.1.232.0.13601800
Severity: Normal -- informational in nature. Deallocation of a Virtual Disk has failed after three attempts due to unknown circumstances. This will more than likely be caused by failing physical drives. The deletion will be restarted when a resync/reboot occurs. The tag1 field contains the identity of the Virtual Disk. The tag2 field contains the identity of the Disk Group. The values that may be found in the status field indicate the returned status from the delete operation.
.1.3.6.1.4.1.232.0.136018001
Api Created Element Success
.1.3.6.1.4.1.232.0.136018002
Api Created Storage Success
.1.3.6.1.4.1.232.0.136018003
Api Created Storage Client Success
.1.3.6.1.4.1.232.0.136018004
Api Set Storage Success
.1.3.6.1.4.1.232.0.136018005
Api Set Element Success
.1.3.6.1.4.1.232.0.136018006
Api Deleted Element Success
.1.3.6.1.4.1.232.0.136018007
Api Deleted Storage Success
.1.3.6.1.4.1.232.0.136018008
Api Deleted Storage Client Success
.1.3.6.1.4.1.232.0.136018009
Api Created Snapshot Success
.1.3.6.1.4.1.232.0.136018010
Api Created Clone Success
.1.3.6.1.4.1.232.0.136018018
Api Unable To Get The Lock
.1.3.6.1.4.1.232.0.136018019
Api Created PresentedUnit Success
.1.3.6.1.4.1.232.0.136018022
Api Create DiskGroup Success
.1.3.6.1.4.1.232.0.136018024
Api Create Folder Success
.1.3.6.1.4.1.232.0.136018025
Api Delete Folder Success
.1.3.6.1.4.1.232.0.136018028
Api Set Folder Success
.1.3.6.1.4.1.232.0.136018034
Api Invalid User Name Or Password Error
.1.3.6.1.4.1.232.0.136018036
Api Delete Presented Unit Success
.1.3.6.1.4.1.232.0.136018038
Api Set Diskgroup Success
.1.3.6.1.4.1.232.0.136018039
Api Set Disk Success
.1.3.6.1.4.1.232.0.136018040
Api Delete Storage Family Success
.1.3.6.1.4.1.232.0.136018041
Api Set Storage Family Success
.1.3.6.1.4.1.232.0.136018042
Api Control Memory Allocation Failure
.1.3.6.1.4.1.232.0.136018045
Api Element Codeload Success
.1.3.6.1.4.1.232.0.136018047
Api Disk Codeload Success
.1.3.6.1.4.1.232.0.136018048
Api Monitor Codeload Success
.1.3.6.1.4.1.232.0.136018049
Api Added Port WWID Success
.1.3.6.1.4.1.232.0.136018050
Api Set Storage Client Success
.1.3.6.1.4.1.232.0.136018051
Api Invalid Operation
.1.3.6.1.4.1.232.0.136018052
Api Deleted Port WWID Success
.1.3.6.1.4.1.232.0.136018059
Api Set Power Success
.1.3.6.1.4.1.232.0.136018060
Api Element Is Not Initialized
.1.3.6.1.4.1.232.0.136018063
Api Error trying to delete a disk group
.1.3.6.1.4.1.232.0.136018065
Api A storage (Vdisk) operation is in progress. Try again later.
.1.3.6.1.4.1.232.0.136018066
Api The storage (Vdisk) condition is invalid. The storage may be in error. Try again later.
.1.3.6.1.4.1.232.0.136018067
Api Error calling get Vdisk condition. Vdisk may be deleted. Try again later.
.1.3.6.1.4.1.232.0.136018068
Api Invalid initialization of the API. Cannot start monitoring process. Storage system management limited.
.1.3.6.1.4.1.232.0.136018070
Api A command is currently under execution from another API call. Try again later.
.1.3.6.1.4.1.232.0.136018071
Api The server has not completed initialization, cannot process the request.
.1.3.6.1.4.1.232.0.136018073
Api Removal of disk from disk group successful
.1.3.6.1.4.1.232.0.136018074
Api Disk(s) added to disk group successfully
.1.3.6.1.4.1.232.0.136018075
Api Modify monitor properties successful
.1.3.6.1.4.1.232.0.136018076
Api Element name too long. Maximum is 20 characters.
.1.3.6.1.4.1.232.0.136018080
Api The snapshot/Snapclone license cannot be validated. Either the license key has not been entered, or there is a system communication failure.
.1.3.6.1.4.1.232.0.136018081
Api The folder operation is not valid for the specified folder. Either the folder is a root folder and cannot be modified, or it is a disk group folder for which you should use 'Set Group' command.
.1.3.6.1.4.1.232.0.136020001
LicMngr Memory Allocation Failure
.1.3.6.1.4.1.232.0.136020002
LicMngr Startup Complete
.1.3.6.1.4.1.232.0.136020003
LicMngr Startup Failed
.1.3.6.1.4.1.232.0.136020004
License successfully checked out
.1.3.6.1.4.1.232.0.136020005
License checkout failed
.1.3.6.1.4.1.232.0.136020011
License Line has an incorrect format
.1.3.6.1.4.1.232.0.136020013
License Library runtime error
.1.3.6.1.4.1.232.0.136020015
Failed to retrieve Node WWN from storage system
.1.3.6.1.4.1.232.0.136020016
Failed to retrieve license list from MLD
.1.3.6.1.4.1.232.0.136020017
Failed to write license list to MLD
.1.3.6.1.4.1.232.0.136020018
This license line appears to be invalid
.1.3.6.1.4.1.232.0.136020019
MLD Manager Handle is NULL - unable to update MLD License List
.1.3.6.1.4.1.232.0.136020020
LicMngr: Storage system handle is NULL
.1.3.6.1.4.1.232.0.136020021
The license you entered is a valid license but not for the Node WWN and/or firmware version on this controller pair
.1.3.6.1.4.1.232.0.136020022
Function name string is null or in an incorrect format
.1.3.6.1.4.1.232.0.136020023
Version string is null or in an incorrect format
.1.3.6.1.4.1.232.0.136021001
HSV Upgrade Manager Image File Open Error
.1.3.6.1.4.1.232.0.136021002
HSV Upgrade Manager Image File Buffer Allocation Error
.1.3.6.1.4.1.232.0.136021003
HSV Upgrade Manager Image File Read Error
.1.3.6.1.4.1.232.0.136021004
HSV Upgrade Manager Event File Write Error
.1.3.6.1.4.1.232.0.136021006
HSV Upgrade Manager Global Header Edc Compute Error
.1.3.6.1.4.1.232.0.136021007
HSV Upgrade Manager Image Header Edc Compute Error
.1.3.6.1.4.1.232.0.136021008
HSV Upgrade Manager Image Type Exceeds Max Image Count
.1.3.6.1.4.1.232.0.136021009
HSV Upgrade Manager Image Type Not Controller Image
.1.3.6.1.4.1.232.0.136021010
HSV Upgrade Manager Image Size Exceeded
.1.3.6.1.4.1.232.0.136021011
HSV Upgrade Manager Event File Open Error
.1.3.6.1.4.1.232.0.136021012
HSV Upgrade Manager Image Edc Compute Error
.1.3.6.1.4.1.232.0.136021013
HSV Upgrade Manager Begin Text Not Found
.1.3.6.1.4.1.232.0.136021014
HSV Upgrade Manager After Text Not Found
.1.3.6.1.4.1.232.0.136021015
HSV Upgrade Manager File Format Version Mismatch
.1.3.6.1.4.1.232.0.136021016
HSV Upgrade Manager Global Header Format Version Mismatch
.1.3.6.1.4.1.232.0.136021017
HSV Upgrade Manager Product Information Was Not Found
.1.3.6.1.4.1.232.0.136021018
HSV Upgrade Manager Event File Was Not Found
.1.3.6.1.4.1.232.0.136021019
HSV Upgrade Manager All Images Match Versions Already Loaded
.1.3.6.1.4.1.232.0.136022001
Trace: Unable to write management agent trace file
.1.3.6.1.4.1.232.0.136022002
Trace: file write succeeded
.1.3.6.1.4.1.232.0.136023002
Diagnostic The view list has errors
.1.3.6.1.4.1.232.0.136023003
Diagnostic Memory allocation failure
.1.3.6.1.4.1.232.0.13602305
Severity: Normal -- informational in nature. The state of the Physical Disk Drive identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>2 = Degraded <LI>3 = Failed <LI>4 = Not present <LI>5 = Single Port on Fibre </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.
.1.3.6.1.4.1.232.0.13602306
Severity: Normal -- informational in nature. The state of a Volume has changed. The identity of the affected Volume is contained in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: <UL><LI>1 = Normal - Volume is present and operating normally <LI>2 = Migrating - Data from this volume is being moved to other storage in this Disk Group <LI>3 = Missing - Volume is inaccessible <LI>4 = Reconstructing - Volume is inaccessible; redundant data is being regenerated and moved to other storage in this Disk Group <LI>5 = Completing - This previously inaccessible volume has become accessible; data migration is being completed <LI>6 = Reverting - This previously inaccessible volume has become accessible; data is being regenerated <LI>7 = Failed - Volume is not being used in the Disk Group; disk errors are preventing normal usage </UL>
.1.3.6.1.4.1.232.0.13602307
Severity: Normal -- informational in nature. The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has changed. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: <UL><LI>1 = Normal <LI>2 = Replacement delay in progress <LI>3 = Redundancy lost, restore in progress <LI>4 = Redundancy lost, restore stalled <LI>5 = Failed <LI>6 = Creation in progress <LI>7 = Snapshot is inoperative due to lack of snapshot space <LI>8 = Deletion in progress <LI>9 = Capacity change in progress <LI>10 = Inoperative due to data lost <LI>11 = Capacity reservation in progress <LI>12 = Capacity unreservation in progress </UL>
.1.3.6.1.4.1.232.0.13602308
Severity: Normal -- informational in nature. The state of the HSV110 controller identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains the old state: 3 (FAILED).
.1.3.6.1.4.1.232.0.13602309
Severity: Normal -- informational in nature. The state of a battery assembly within the HSV110 controller identified in the handle field has changed. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: <UL><LI>1 = Battery System Hold-up Time is greater than 96 hours <LI>3 = Battery System Hold-up Time is greater than 0 and less than 96 hours <LI>5 = Battery System Hold-up Time is zero hours </UL>
.1.3.6.1.4.1.232.0.13602310
Severity: Undetermined -- more information needed to determine severity. A Volume has transitioned to the MISSING state. The affected Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state. The value.ul2 field contains the old state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: <UL><LI>1 = Normal - Volume is present and operating normally <LI>2 = Migrating - Data from this volume is being moved to other storage in this Disk Group <LI>4 = Reconstructing - Volume is inaccessible; redundant data is being regenerated and moved to other storage in this Disk Group <LI>5 = Completing - This previously inaccessible volume has become accessible; data migration is being completed <LI>6 = Reverting - This previously inaccessible volume has become accessible; data is being regenerated <LI>7 = Failed - Volume is not being used in the Disk Group; disk errors are preventing normal usage </UL>
.1.3.6.1.4.1.232.0.13602311
Severity: Normal -- informational in nature. The state of the Fibre Channel port identified in the attribute.value.str field and located on the rear panel of the HSV110 controller identified in the handle field has transitioned to the NORMAL state. The attribute.type field contains the value 4. The value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains the old state: 2 (FAILED). <P> Note that the HSV110 controller's internal identity of the affected Fibre Channel port is contained in the secondary_id field.
.1.3.6.1.4.1.232.0.13602312
Severity: Warning -- not failed but attention recommended or required. The Occupancy Alarm Level threshold has been reached for the Disk Group identified in the handle field.
.1.3.6.1.4.1.232.0.13602313
Severity: Normal -- informational in nature. The Resource Availability state of a Volume has transitioned to the SUFFICIENT state. The affected Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state: 0 (SUFFICIENT). The value.ul2 field contains the old state: 1 (INSUFFICIENT).
.1.3.6.1.4.1.232.0.13602314
Severity: Normal -- informational in nature. The Data Availability state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new state: 0 (NORMAL). The value.ul2 field contains the old state: 1 (DATA LOST).
.1.3.6.1.4.1.232.0.13602316
Severity: Normal -- informational in nature. The Snapclone Logical Disk identified in the handle field has completed the unsharing operation. The secondary_id field contains the noid of the associated successor internal Logical Disk.
.1.3.6.1.4.1.232.0.13602317
Severity: Normal -- informational in nature. The state of the Quorum Disk flag of a Volume has changed. The affected Volume is identified in the handle field. The value.ul1 field contains the new state of the Quorum Disk flag. The value.ul2 field contains the old state of the Quorum Disk flag. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: <UL><LI>0 = Not quorum disk <LI>1 = Quorum disk </UL>
.1.3.6.1.4.1.232.0.13602318
Severity: Critical -- failure or failure imminent. The temperature trip point for a temperature sensor located within an HSV110 controller has been reached. The HSV110 controller is identified in the handle field. The value.ul1 field contains the current temperature reading from I2C sensor 1 in degrees celsius while the value.ul2 field contains the adjusted reading from I2C sensor 2. The set temperature trip point is contained in the secondary_id field.
.1.3.6.1.4.1.232.0.13602319
Severity: Warning -- not failed but attention recommended or required. The temperature within the HSV110 controller identified in the handle field is approaching its trip point. The value.ul1 field contains the current temperature reading from I2C sensor 1 in degrees celsius while the value.ul2 field contains the adjusted reading from I2C sensor 2. The secondary_id field contains the set temperature trip point in Celsius.
.1.3.6.1.4.1.232.0.13602321
Severity: Normal -- informational in nature. The Blower Present flag for the '1' blower assembly located within the HSV110 controller identified in the handle field has transitioned from the NOT PRESENT to PRESENT state indicating that the blower has been reinstalled. The secondary_id field contains the '1' blower assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 0 (NOT PRESENT).
.1.3.6.1.4.1.232.0.13602322
Severity: Critical -- failure or failure imminent. The '1' blower located within the HSV110 controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the '1' blower assembly internal identifier value: 1. The value.ul1 field contains the current speed of the '1' blower. The value.ul2 field contains the lowest acceptable speed for the '1' blower.
.1.3.6.1.4.1.232.0.13602323
Severity: Normal -- informational in nature. One of the voltage sensors located within the HSV110 controller identified in the handle field has reported a voltage that is out of range. The value.ul1 field contains the out of range voltage value. The secondary_id field contains the specific voltage threshold value (i.e., 12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in millivolts--e.g.,12.5V is expressed as 12500.
.1.3.6.1.4.1.232.0.13602324
Severity: Undetermined -- more information needed to determine severity. The state of a Volume has transitioned to the FAILED state. The affected Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state: 7 (FAILED). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 fields are as follows: <UL><LI>1 = Normal - Volume is present and operating normally <LI>2 = Migrating - Data from this volume is being moved to other storage in this Disk Group <LI>3 = Missing - Volume is inaccessible <LI>4 = Reconstructing - Volume is inaccessible; redundant data is being regenerated and moved to other storage in this Disk Group <LI>5 = Completing - This previously inaccessible volume has become accessible; data migration is being completed <LI>6 = Reverting - This previously inaccessible volume has become accessible; data is being regenerated </UL>
.1.3.6.1.4.1.232.0.13602325
Severity: Undetermined -- more information needed to determine severity. An HSV110 controller has failed. The state of the HSV110 controller identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the old state: 1 (NORMAL).
.1.3.6.1.4.1.232.0.13602326
Severity: Normal -- informational in nature. The temperature within the HSV110 controller identified in the handle field has returned to its normal operating range. The value.ul1 field contains the current temperature reading in celsius from I2C sensor 1, while the value.ul2 field contains the adjusted reading from I2C sensor 2.
.1.3.6.1.4.1.232.0.13602327
Severity: Critical -- failure or failure imminent. An HSV110 controller's battery assembly has been removed. The Battery Present flag for battery assembly '1' located within the HSV110 controller identified in the handle field has changed from PRESENT to NOT PRESENT indicating that the battery assembly was removed. The secondary_id field contains the battery assembly '1' internal identifier value: 1. The value.ul1 field contains the new state of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 1 (PRESENT).
.1.3.6.1.4.1.232.0.13602328
Severity: Normal -- informational in nature. The Battery In Use flag for battery assembly '1' located within the HSV110 controller identified in the handle field has transitioned from the NOT IN USE to IN USE state indicating that the battery assembly is functioning properly. The secondary_id field contains the battery assembly '1' internal identifier value: 1. The value.ul1 field contains the new state of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 0 (NOT IN USE).
.1.3.6.1.4.1.232.0.13602329
Severity: Normal -- informational in nature. One of the voltage sensors located within the HSV110 controller identified in the handle field has reported a voltage that indicates that a voltage that was previously out of range has returned to the normal range. The value.ul1 field contains the normal range voltage value. The secondary_id field contains the voltage threshold value (i.e., 12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in thousands--e.g., 12.5V is expressed as 12500.
.1.3.6.1.4.1.232.0.13602330
Severity: Warning -- not failed but attention recommended or required. The battery assembly voltage regulator located within the HSV110 controller identified in the handle field is offline.
.1.3.6.1.4.1.232.0.13602331
Severity: Normal -- informational in nature. The state of the Disk Group identified in the handle field has transitioned to the NORMAL state. The value.ul1 field contains the new Disk Group state: 1 (NORMAL). The value.ul2 field contains the old Disk Group state. The state values that may be found in the value.ul2 field are as follows: <UL><LI>2 = Disk Group with no redundancy is inoperative <LI>3 = Disk Group with parity redundancy is inoperative <LI>4 = Disk Group with mirrored redundancy is inoperative <LI>5 = Disk Group with no redundancy is inoperative, marked for re-use <LI>6 = Disk Group with parity redundancy is inoperative, marked for re-use <LI>7 = Disk Group with mirrored redundancy is inoperative, marked for re-use </UL>
.1.3.6.1.4.1.232.0.13602332
Severity: Normal -- informational in nature. The Occupancy Alarm Level for the Disk Group identified in the handle field has returned to the normal range.
.1.3.6.1.4.1.232.0.13602333
Severity: Critical -- failure or failure imminent. An HSV110 controller's battery assembly has malfunctioned. The Battery In Use flag for battery assembly '1' located within the HSV110 controller identified in the handle field has transitioned from the IN USE to NOT IN USE state indicating that the battery assembly has malfunctioned. The secondary_id field contains the battery assembly '1' internal identifier value: 1. The value.ul1 field contains the new state of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 1 (IN USE).
.1.3.6.1.4.1.232.0.13602334
Severity: Normal -- informational in nature. The Battery Present flag for battery assembly '1' located within the HSV110 controller identified in the handle field has changed from NOT PRESENT to PRESENT indicating that the battery assembly was reinstalled. The secondary_id field contains the battery assembly '1' internal identifier value: 1. The value.ul1 field contains the new state of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 0 (NOT PRESENT).
.1.3.6.1.4.1.232.0.13602335
Severity: Critical -- failure or failure imminent. An HSV110 controller's battery assembly has been removed. The Battery Present flag for battery assembly '2' located within the HSV110 controller identified in the handle field has changed from PRESENT to NOT PRESENT indicating that the battery assembly was removed. The secondary_id field contains the battery assembly '2' internal identifier value: 2. The value.ul1 field contains the new state of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 1 (PRESENT).
.1.3.6.1.4.1.232.0.13602336
Severity: Normal -- informational in nature. The Battery Present flag for battery assembly '2' located within the HSV110 controller identified in the handle field has changed from NOT PRESENT to PRESENT indicating that the battery assembly was reinstalled. The secondary_id field contains the battery assembly '2' internal identifier value: 2. The value.ul1 field contains the new state of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Battery Present flag: 0 (NOT PRESENT).
.1.3.6.1.4.1.232.0.13602337
Severity: Normal -- informational in nature. The Battery In Use flag for battery assembly '2' located within the HSV110 controller identified in the handle field has transitioned from the NOT IN USE to IN USE state indicating that the battery assembly is functioning properly. The secondary_id field contains the battery assembly '2' internal identifier value: 2. The value.ul1 field contains the new state of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 0 (NOT IN USE).
.1.3.6.1.4.1.232.0.13602338
Severity: Critical -- failure or failure imminent. An HSV110 controller's battery assembly has malfunctioned. The Battery In Use flag for battery assembly '2' located within the HSV110 controller identified in the handle field has transitioned from the IN USE to NOT IN USE state indicating that the battery assembly has malfunctioned. The secondary_id field contains the battery assembly '2' internal identifier value: 2. The value.ul1 field contains the new state of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old state of the Battery In Use flag: 1 (IN USE).
.1.3.6.1.4.1.232.0.13602339
Severity: Critical -- failure or failure imminent. The Blower Present flag for the '2' blower assembly located within the HSV110 controller identified in the handle field has transitioned from the PRESENT to NOT PRESENT state indicating that the blower has been removed. The secondary_id field contains the '2' blower assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 1 (PRESENT).
.1.3.6.1.4.1.232.0.13602340
Severity: Normal -- informational in nature. The Blower Present flag for the '2' blower assembly located within the HSV110 controller identified in the handle field has transitioned from the NOT PRESENT to PRESENT state indicating that the blower has been reinstalled. The secondary_id field contains the '2' blower assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 0 (NOT PRESENT).
.1.3.6.1.4.1.232.0.13602341
Severity: Critical -- failure or failure imminent. The '2' blower located within the HSV110 controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the '2' blower assembly internal identifier value: 2. The value.ul1 field contains the current speed of the '2' blower. The value.ul2 field contains the lowest acceptable speed for the '2' blower.
.1.3.6.1.4.1.232.0.13602342
Severity: Critical -- failure or failure imminent. An HSV110 controller's '1' blower/power supply assembly has been removed or AC power has been removed from the power supply. The HSV110 controller is identified in the handle field. The secondary_id field contains the '1' blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 1 (PRESENT).
.1.3.6.1.4.1.232.0.13602343
Severity: Normal -- informational in nature. An HSV110 controller's '1' blower/power supply assembly has been reinstalled or AC power has been restored to the power supply. The HSV110 controller is identified in the handle field. The secondary_id field contains the '1' blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 0 (NOT PRESENT).
.1.3.6.1.4.1.232.0.13602344
Severity: Critical -- failure or failure imminent. An HSV110 controller's '2' blower/power supply assembly has been removed or AC power has been removed from the power supply. The HSV110 controller is identified in the handle field. The secondary_id field contains the '2' blower/power supply assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 1 (PRESENT).
.1.3.6.1.4.1.232.0.13602345
Severity: Normal -- informational in nature. An HSV110 controller's '2' blower/power supply assembly has been reinstalled or AC power has been restored to the power supply. The HSV110 controller is identified in the handle field. The secondary_id field contains the '2' blower/power supply assembly internal identifier value: 2. The value.ul1 field contains the new state of the Blower/Power Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the Blower/Power Supply Present flag: 0 (NOT PRESENT).
.1.3.6.1.4.1.232.0.13602346
Severity: Critical -- failure or failure imminent. The '1' blower/power supply located within the HSV110 controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the '1' blower/power supply assembly internal identifier value: 1. The value.ul1 field contains the current speed of the '1' blower/power supply. The value.ul2 field contains the lowest acceptable speed for the '1' blower/power supply.
.1.3.6.1.4.1.232.0.13602347
Severity: Critical -- failure or failure imminent. The '2' blower/power supply located within the HSV110 controller identified in the handle field is running slower than the lowest acceptable speed. The secondary_id field contains the '2' blower/power supply assembly internal identifier value: 2. The value.ul1 field contains the current speed of the '2' blower/power supply. The value.ul2 field contains the lowest acceptable speed for the '2' blower/power supply.
.1.3.6.1.4.1.232.0.13602348
Severity: Warning -- not failed but attention recommended or required. The state of a battery assembly within the HSV110 controller identified in the handle field has transitioned to the Battery System Hold-up Time is zero hours state. The value.ul1 field contains the new state 5: (Battery System Hold-up Time is zero hours). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: <UL><LI>1 = Battery System Hold-up Time is greater than 96 hours <LI>3 = Battery System Hold-up Time is greater than 0 and less than 96 hours <LI>5 = Battery System Hold-up Time is zero hours </UL>
.1.3.6.1.4.1.232.0.13602349
Severity: Undetermined -- more information needed to determine severity. The Resource Availability state of a Volume has transitioned to the INSUFFICIENT state. The affected Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The internal identification of that Volume's Redundant Storage Set is contained in the attribute.value.u32[3] field. The attribute.type field contains the value of 1. The value.ul1 field contains the new state: 1 (INSUFFICIENT). The value.ul2 field contains the old state: 0 (SUFFICIENT).
.1.3.6.1.4.1.232.0.13602350
Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field rejected a login attempt. The value.ul1 and value.ul2 fields contain words [0] and [1], respectively, of the World Wide Name of the host adapter that originated the rejected login attempt. The secondary_id field contains the reason for the rejection as follows: <UL><LI>50 = The host is already logged in <LI>101 = Maximum number of logins is exceeded <LI>102 = Invalid cookie was sent <LI>106 = The password is not set on the HSV110 controller </UL>
.1.3.6.1.4.1.232.0.13602351
Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field processed a Storage System Management Interface command with the result of non-success return code. The value.ul1 field contains internal the command type. The value.ul2 field contains the internal return code. The attribute.value.obj field contains the internal target and internal version of the command.
.1.3.6.1.4.1.232.0.13602352
Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has updated the physical disk drive map for the loop pair identified in the secondary_id field. The value.ul1 field contains the new internal map generation number. The value.ul2 field contains the old internal map generation number.
.1.3.6.1.4.1.232.0.13602353
Severity: Critical -- failure or failure imminent. The state of the Physical Disk Drive identified in the handle field has transitioned to the DEGRADED state. The value.ul1 field contains the new state: 2 (DEGRADED). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>3 = Failed <LI>4 = Not present <LI>5 = Single Port on Fibre </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.
.1.3.6.1.4.1.232.0.13602354
Severity: Critical -- failure or failure imminent. The state of the Physical Disk Drive identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Degraded <LI>4 = Not present <LI>5 = Single Port on Fibre </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.
.1.3.6.1.4.1.232.0.13602355
Severity: Normal -- informational in nature. The Derived Unit identified in the handle field was created. The add_handle field contains the identity of the Storage System Virtual Disk that is associated with that Derived Unit. The attribute.value.obj field contains the identity of the Virtual Disk associated with that Derived Unit.
.1.3.6.1.4.1.232.0.13602356
Severity: Normal -- informational in nature. The internal Logical Disk associated with the Virtual Disk identified in the handle field was created. The add_handle field contains the identity of the Disk Group where this internal Logical Disk was created. The attribute.value.u64[0] field contains the size (in blocks) of the internal Logical Disk. The attribute.value.u32[2] field contains the redundancy type of the internal Logical Disk. The attribute.type field contains the value 5. The values that may be found in the attribute.value.u32[2] field are as follows: <UL><LI>1 = Vraid0 <LI>2 = Vraid1 <LI>3 = Vraid5 </UL>
.1.3.6.1.4.1.232.0.13602357
Severity: Normal -- informational in nature. The Disk Group identified in the handle field was created. The attribute.value.u32[0] field contains the number of physical disk drives within the Disk Group. The attribute.type field contains the value 1.
.1.3.6.1.4.1.232.0.13602358
Severity: Normal -- informational in nature. The Physical Disk Drive identified in the handle field was discovered. The enclosure, bay and rack where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1] and attribute.value.u32[2] fields, respectively. The attribute.type field contains the value 1.
.1.3.6.1.4.1.232.0.13602359
Severity: Normal -- informational in nature. The Presented Unit identified in the handle field was created. The add_handle field contains the identity of the Storage System Virtual Disk that is associated with the Presented Unit. This Presented Unit is associated with the Virtual Disk identified in the attribute.value.obj.handle field. The add_handle2 field contains the associated Storage System Host path, and add_data[0] and add_data[1] contains the host LUN number.
.1.3.6.1.4.1.232.0.13602360
Severity: Normal -- informational in nature. The Storage System Host path identified in the handle field was created.
.1.3.6.1.4.1.232.0.13602361
Severity: Normal -- informational in nature. The Storage System Virtual Disk identified in the handle field was created.
.1.3.6.1.4.1.232.0.13602362
Severity: Normal -- informational in nature. A Volume was created. The Volume is identified in the handle field. The add_handle field contains the identity of the Physical Disk Drive that is associated with that Volume. The enclosure number, bay number, and rack number where the associated Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], and attribute.value.u32[2] fields, respectively. The attribute.type field contains the value of 1.
.1.3.6.1.4.1.232.0.13602363
Severity: Normal -- informational in nature. The Derived Unit identified in the handle field was deleted. The add_handle field contains the identity of the Storage System Virtual Disk that was associated with the Derived Unit. This Derived Unit is associated with the Virtual Disk identified in the attribute.value.obj.handle field.
.1.3.6.1.4.1.232.0.13602364
Severity: Normal -- informational in nature. The internal Logical Disk associated with the Virtual Disk identified in the handle field was deleted.
.1.3.6.1.4.1.232.0.13602365
Severity: Normal -- informational in nature. The Disk Group identified in the handle field was deleted.
.1.3.6.1.4.1.232.0.13602366
Severity: Critical -- failure or failure imminent. The Physical Disk Drive identified in the handle field has disappeared. The enclosure, bay and rack where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1] and attribute.value.u32[2] fields, respectively. The attribute.type field contains the value 1.
.1.3.6.1.4.1.232.0.13602367
Severity: Normal -- informational in nature. The Presented Unit identified in the handle field was deleted. The add_handle field contains the identity of the Storage System Virtual Disk that was associated with the Presented Unit. This Presented Unit is associated with the Virtual Disk identified in the attribute.value.obj.handle field.
.1.3.6.1.4.1.232.0.13602368
Severity: Normal -- informational in nature. The Storage System Host path identified in the handle field was deleted.
.1.3.6.1.4.1.232.0.13602369
Severity: Normal -- informational in nature. The Storage System Virtual Disk identified in the handle field was deleted. The Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field.
.1.3.6.1.4.1.232.0.13602371
Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has joined the Storage System. If the handle field is zero, the HSV110 controller identity could not be obtained due to an unexpected state transition.
.1.3.6.1.4.1.232.0.13602372
Severity: Undetermined -- more information needed to determine severity. An HSV110 controller has left the Storage System. The HSV110 controller is identified in the handle field. If the handle field is zero, the HSV110 controller identity could not be obtained due to an unexpected state transition.
.1.3.6.1.4.1.232.0.13602373
Severity: Normal -- informational in nature. A Storage System has been deleted by an HSV110 controller. The Storage System is identified in the handle field. The HSV110 controller is identified in the add_handle field. If the handle field or add_handle field is zero, the corresponding identity could not be obtained due to an unexpected state transition.
.1.3.6.1.4.1.232.0.13602374
Severity: Normal -- informational in nature. The Data Replication Group identified in the handle field was created.
.1.3.6.1.4.1.232.0.13602375
Severity: Normal -- informational in nature. The Data Replication Group identified in the handle field was deleted.
.1.3.6.1.4.1.232.0.13602376
Severity: Normal -- informational in nature. The internal Logical Disk associated with the Snapshot Virtual Disk identified in the handle field was created. The add_handle field contains the identity of the Disk Group where this internal Logical Disk was created. The attribute.value.u64[0] field contains the size (in blocks) of the reserved capacity of the internal Logical Disk. The attribute.value.u32[2] field contains the redundancy type of the internal Logical Disk. The attribute.value.u32[3] field contains the noid of the associated successor internal Logical Disk. The attribute.type field contains the value 6. The values that may be found in the attribute.value.u32[2] field are as follows: <UL><LI>1 = Vraid0 <LI>2 = Vraid1 <LI>3 = Vraid5 </UL>
.1.3.6.1.4.1.232.0.13602377
Severity: Normal -- informational in nature. The internal Logical Disk associated with the Copy of the Virtual Disk identified in the handle field was created. The add_handle field contains the identity of the Disk Group where this internal Logical Disk was created. The attribute.value.u64[0] field contains the size (in blocks) of the reserved capacity of the target Virtual Disk. The attribute.value.u32[2] field contains the redundancy type of the internal Logical Disk. The attribute.value.u32[3] field contains the noid of the associated successor internal Logical Disk. The attribute.type field contains the value 6. The values that may be found in the attribute.value.u32[2] field are as follows: <UL><LI>1 = Vraid0 <LI>2 = Vraid1 <LI>3 = Vraid5 </UL>
.1.3.6.1.4.1.232.0.136024001
Windows system error
.1.3.6.1.4.1.232.0.136024002
Lock is already taken
.1.3.6.1.4.1.232.0.136024003
Lock is not taken
.1.3.6.1.4.1.232.0.136024004
Request timed out
.1.3.6.1.4.1.232.0.13602405
Severity: Normal -- informational in nature. The Host Operating System mode of the Storage System Host identified in the handle field has changed. The old_attr.type and new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Host Operating System mode. The new_attr.value.u32[0] field contains the new Host Operating System mode. The values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>0 = Unknown <LI>1 = User defined <LI>2 = Unused <LI>3 = WINNT with SecurePath <LI>4 = VMS <LI>5 = TRU64 UNIX <LI>6 = Sun UNIX <LI>7 = NetWare <LI>8 = HP <LI>9 = IBM <LI>10 = LINUX <LI>11 = SCO UNIX </UL>
.1.3.6.1.4.1.232.0.13602406
Severity: Normal -- informational in nature. Time was set on the Storage System identified in the handle field.
.1.3.6.1.4.1.232.0.13602407
Severity: Normal -- informational in nature. The LUN of the Presented Unit identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0..1] fields contain the value of the old LUN. The new_attr.value.u32[0..1] fields contain the value of the new LUN. The secondary_id field contains the noid portion of the handle for the Storage System Virtual Disk associated with the Presented Unit. This Presented Unit is associated with the Virtual Disk identified in the add_handle field.
.1.3.6.1.4.1.232.0.13602408
Severity: Normal -- informational in nature. The Device Addition Policy of the Storage System identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Device Addition Policy. The new_attr.value.u32[0] field contains the new Device Addition Policy. The policy values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Manual policy <LI>2 = Automatic policy </UL>
.1.3.6.1.4.1.232.0.13602409
Severity: Normal -- informational in nature. The Quiescent state of the Storage System Virtual Disk identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Quiescent state. The new_attr.value.u32[0] field contains the new Quiescent state. The state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>0 = Not quiescent <LI>1 = Quiescent </UL>This Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field.
.1.3.6.1.4.1.232.0.13602410
Severity: Normal -- informational in nature. The Enabled/Disabled state of the Storage System Virtual Disk identified in the handle field has changed. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Enabled/Disabled state. The new_attr.value.u32[0] field contains the new Enabled/Disabled state. The state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disabled <LI>2 = Enabled </UL>This Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field.
.1.3.6.1.4.1.232.0.13602411
Severity: Normal -- informational in nature. The Cache Policy of the Storage System Virtual Disk identified in the handle field has changed. <P> The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Write Cache Policy. The new_attr.value.u32[0] field contains the new Write Cache Policy. The policy values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Writethrough <LI>2 = Writeback </UL><P> The old_attr.value.u32[1] field contains the old Read Cache Policy. The new_attr.value.u32[1] field contains the new Read Cache Policy. The policy values that may be found in the old_attr.value.u32[1] and new_attr.value.u32[1] fields are as follows: <UL><LI>1 = Read cache on <LI>2 = Read cache off </UL><P> The old_attr.value.u32[2] field contains the old Cache Mirroring Policy. The new_attr.value.u32[2] field contains the new Cache Mirroring Policy. The policy values that may be found in the old_attr.value.u32[2] and new_attr.value.u32[2] fields are as follows: <UL><LI>1 = Mirror <LI>2 = No mirror </UL>This Storage System Virtual Disk is associated with the Virtual Disk identified in the add_handle field.
.1.3.6.1.4.1.232.0.13602412
Severity: Normal -- informational in nature. The Usage state of a Volume changed. The affected Volume is identified in the handle field. The old_attr.value.u32[0] field contains the old Usage state. The new_attr.value.u32[0] field contains the new Usage state. The Usage state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Disk Group <LI>2 = Reserved <LI>4 - 20 = temporary usage reserved for drive code load </UL>This Volume is associated with the Disk Group identified in the add_handle field, if either the old Usage state or the new Usage state is 1. The secondary_id field contains the internal identification of that Volume's Redundant Storage Set.
.1.3.6.1.4.1.232.0.13602413
Severity: Normal -- informational in nature. The Disk Failure Protection Level of the Disk Group identified in the handle field has changed. The old_attr.type and new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old number of physical disk drives available for use. The new_attr.value.u32[0] field contains the new number of physical disk drives available for use.
.1.3.6.1.4.1.232.0.13602414
Severity: Normal -- informational in nature. The Write Protected state of the Derived Unit identified in the handle field has changed. This Derived Unit is associated with the Virtual Disk identified in the add_handle field. The secondary_id field contains the noid portion of the handle for the Storage System Virtual Disk associated with the Derived Unit. The old_attr.type field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field contains the old Write Protected state. The new_attr.value.u32[0] field contains the new Write Protected state. The Write Protected state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>0 = Write protect off <LI>1 = Write protect on </UL>This Derived Unit is associated with the Virtual Disk identified in the add_handle field.
.1.3.6.1.4.1.232.0.13602416
Severity: Warning -- not failed but attention recommended or required. The Physical Disk Drive identified in the handle field has experienced numerous communication failures on a particular Fibre Channel port identified in the new_attr.value.str field. The old_attr.value.u32[0] field contains the internal port ID. The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the old_attr.value.u32[1], old_attr.value.u32[2], old_attr.value.u32[3] fields, respectively. The old_attr.type field contains value 1. The new_attr.value.str field contains the cerp_id of the Fibre Channel port. The new_attr.type field contains value 4.
.1.3.6.1.4.1.232.0.13602417
Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field received a request to shutdown. <P> The old_attr.type field and field contain the value 1. The old_attr.value.u32[0] field indicates the type of restart that was requested as follows: <UL><LI>0 = None -- no restart <LI>1 = Regular -- full restart, host system connectivity is lost until the controller returns to normal operation <LI>2 = Fast -- resynchronization, restart of the controller in a manner that has little or no impact on host system connectivity </UL><P> The old_attr.value.u32[1] field indicates whether the other HSV110 controller of the pair was requested to remain operational or to also shutdown as follows: <UL><LI>0 = Remain operational <LI>1 = Coupled shutdown </UL><P> The old_attr.value.u32[2] field indicates whether the HSV110 controller was requested to remain in the power on state or power itself off as follows: <UL><LI>0 = Remain in the power on state <LI>1 = Power itself off </UL><P> The old_attr.value.u32[3] field value indicates whether the Physical Disk Drive enclosure(s) was requested to remain in the power on state or to be powered off as follows: <UL><LI>0 = Remain in the power on state <LI>1 = Powered off </UL><P> The old_attr.value.u32[4] field value indicates whether the battery assemblies located within the HSV110 controller were requested to be enabled or disabled as follows: <UL><LI>0 = Enabled <LI>1 = Disabled </UL><P> The old_attr.value.u32[5] field contains the number of seconds the shutdown operation was requested to be delayed.
.1.3.6.1.4.1.232.0.13602418
Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has completed its shutdown preparations. <P> The old_attr.type field contain the value 1. The old_attr.value.u32[0] field value indicates the result of the HSV110 controller Cache Memory shutdown operation as follows: <UL><LI>1 = Success <LI>2 = Failure <LI>3 = Not applicable </UL><P> The old_attr.value.u32[1] field contains the internal Storage System Management Interface cache shutdown status code. <P> The old_attr.value.u32[2] field value indicates the result of the Physical Disk Drive enclosure(s) power off operation as follows: <UL><LI>1 = Success <LI>2 = Failure <LI>3 = Not applicable </UL><P> The old_attr.value.u32[3] field contains the internal Storage System Management Interface Physical Disk Drive enclosure(s) power off status code. <P> The old_attr.value.u32[4] field value indicates the result of the battery assemblies disable operation as follows: <UL><LI>1 = Success <LI>2 = Failure <LI>3 = Not applicable </UL><P> The old_attr.value.u32[5] field value indicates the battery assemblies disable operation failure mode as follows: <UL><LI>0 = No failure indicated. <LI>1 = Failed only on the HSV110 controller identified in the handle field. <LI>2 = Failed only on the other HSV110 controller of the pair. <LI>3 = Failed on both HSV110 controllers. </UL>
.1.3.6.1.4.1.232.0.13602419
Severity: Normal -- informational in nature. The Failsafe state of the Data Replication Group identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Failsafe state. The new_attr.value.u32[0] field contains the new Failsafe state. The Failsafe state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Failsafe Disabled <LI>2 = Failsafe Enabled </UL>
.1.3.6.1.4.1.232.0.13602420
Severity: Normal -- informational in nature. The Mode of the Data Replication Group identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Mode. The new_attr.value.u32[0] field contains the new Mode. The Mode values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>0 = Normal Active Source <LI>1 = Normal Active Destination <LI>2 = Active/Active (Master) <LI>3 = Active/Active (Non-Master) </UL>
.1.3.6.1.4.1.232.0.13602421
Severity: Normal -- informational in nature. The Operational state of a Data Replication Group has changed to Synchronous or Asynchronous. The old_attr.value.u32[0] field contains the old Operation state. The new_attr.value.u32[0] field contains the new Operation state. The Operation state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Synchronous <LI>2 = Asynchronous </UL>
.1.3.6.1.4.1.232.0.13602422
Severity: Normal -- informational in nature. The Read Only attribute of the Data Replication Group identified in the handle field has changed. The old_attr.value.u32[0] field contains the old Read Only attribute. The new_attr.value.u32[0] field contains the new Read Only attribute. The Read Only attribute values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>0 = Data Replication Destination Storage System Virtual Disk disabled for read access. <LI>1 = Data Replication Destination Storage System Virtual Disk enabled for read access. </UL>
.1.3.6.1.4.1.232.0.13602423
Severity: Normal -- informational in nature. A Data Replication Group failover has occurred. The handle field contains the identity of the Data Replication Group. The old_attr.value.u32[0] field contains the old Role. The new_attr.value.u32[0] field contains the new Role. <UL><LI>0 = Normal Active Source <LI>1 = Normal Active Destination <LI>2 = Active/Active (Master) <LI>3 = Active/Active (Non-Master) </UL>
.1.3.6.1.4.1.232.0.13602424
Severity: Normal -- informational in nature. A Data Replication Group has been suspended or resumed. The handle field contains the identity of the Data Replication Group. The old_attr.value.u32[0] field contains the old Suspend state. The new_attr.value.u32[0] field contains the new Suspend state. The Suspend state values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: <UL><LI>1 = Connection between the Data Replication Source and Data Replication Destination is active. <LI>2 = Connection between the Data Replication Source and Data Replication Destination is inactive. </UL>
.1.3.6.1.4.1.232.0.13602425
Severity: Normal -- informational in nature. A Storage System Virtual Disk was added to a Data Replication Group. The Storage System Virtual Disk is identified in the add_handle field. The Data Replication Group is identified in the handle field.
.1.3.6.1.4.1.232.0.13602426
Severity: Normal -- informational in nature. A Storage System Virtual Disk was removed from a Data Replication Group. The Storage System Virtual Disk is identified in the add_handle field. The Data Replication Group is identified in the handle field.
.1.3.6.1.4.1.232.0.136025001
No path to controller
.1.3.6.1.4.1.232.0.136025002
Thread is not running
.1.3.6.1.4.1.232.0.136025003
No physical stores
.1.3.6.1.4.1.232.0.136025004
Loop context ID changed
.1.3.6.1.4.1.232.0.136025005
Storage Cell context ID changed
.1.3.6.1.4.1.232.0.136025006
Cache Write Failure
.1.3.6.1.4.1.232.0.136025007
Battery Disable Failure
.1.3.6.1.4.1.232.0.136025008
Drive Shelf Disable Failure
.1.3.6.1.4.1.232.0.136025009
Shutdown Both Restart And Power Off Requested
.1.3.6.1.4.1.232.0.136025010
Shutdown Drive Shelf Power Off But No Enclosure Power Off Requested
.1.3.6.1.4.1.232.0.136025011
Shutdown Disable Battery But No Enclosure Power Off Requested
.1.3.6.1.4.1.232.0.136025012
Shutdown Disable Battery But Shutdown Unconditional Requested
.1.3.6.1.4.1.232.0.136025013
Shutdown Delay Out Of Range
.1.3.6.1.4.1.232.0.136025014
Invalid Storage Cell name
.1.3.6.1.4.1.232.0.136025015
Requested spares goal cannot be satisfied
.1.3.6.1.4.1.232.0.136025016
No valid LDAD found
.1.3.6.1.4.1.232.0.136025017
Mismatched MLD size
.1.3.6.1.4.1.232.0.136025018
Codeload image file error
.1.3.6.1.4.1.232.0.136025019
Storage System is not initialized
.1.3.6.1.4.1.232.0.13602504
Severity: Undetermined -- more information needed to determine severity. The Data Availability state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the DATA LOST state. The value.ul1 field contains the new state: 1 (DATA LOST). The value.ul2 field contains the old state: 0 (NORMAL).
.1.3.6.1.4.1.232.0.13602505
Severity: Undetermined -- more information needed to determine severity. The state of the Disk Group identified in the handle field has transitioned to an INOPERATIVE state. The value.ul1 field contains the new Disk Group state. The value.ul2 field contains the old Disk Group state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: <UL><LI>1 = Normal <LI>2 = Disk Group with no redundancy is inoperative <LI>3 = Disk Group with parity redundancy is inoperative <LI>4 = Disk Group with mirrored redundancy is inoperative <LI>5 = Disk Group with no redundancy is inoperative, marked for re-use <LI>6 = Disk Group with parity redundancy is inoperative, marked for re-use <LI>7 = Disk Group with mirrored redundancy is inoperative, marked for re-use </UL>
.1.3.6.1.4.1.232.0.13602506
Severity: Undetermined -- more information needed to determine severity. The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the FAILED state. The value.ul1 field contains the new state: 5 (FAILED). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Replacement delay in progress <LI>3 = Redundancy lost, restore in progress <LI>4 = Redundancy lost, restore stalled <LI>6 = Creation in progress <LI>7 = Snapshot is inoperative due to lack of snapshot space <LI>8 = Deletion in progress <LI>9 = Capacity change in progress <LI>10 = Inoperative due to data lost <LI>11 = Capacity reservation in progress <LI>12 = Capacity unreservation in progress </UL>
.1.3.6.1.4.1.232.0.13602507
Severity: Critical -- failure or failure imminent. The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the SNAPSHOT OVERCOMMIT state. The value.ul1 field contains the new state: 7 (SNAPSHOT OVERCOMMIT). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Replacement delay in progress <LI>3 = Redundancy lost, restore in progress <LI>4 = Redundancy lost, restore stalled <LI>5 = Failed <LI>6 = Creation in progress <LI>8 = Deletion in progress <LI>9 = Capacity change in progress <LI>10 = Inoperative due to device data lost <LI>11 = Capacity reservation in progress <LI>12 = Capacity unreservation in progress </UL>
.1.3.6.1.4.1.232.0.13602508
Severity: Undetermined -- more information needed to determine severity. The state of the internal Logical Disk associated with the Virtual Disk identified in the handle field has transitioned to the DEVICE DATA LOST state. The value.ul1 field contains the new state: 10 (DEVICE DATA LOST). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Replacement delay in progress <LI>3 = Redundancy lost restore, in progress <LI>4 = Redundancy lost restore, stalled <LI>5 = Failed <LI>6 = Creation in progress <LI>7 = Snapshot is inoperative due to lack of snapshot space <LI>8 = Deletion in progress <LI>9 = Capacity change in progress <LI>11 = Capacity reservation in progress <LI>12 = Capacity unreservation in progress </UL>
.1.3.6.1.4.1.232.0.13602509
Severity: Undetermined -- more information needed to determine severity. The state of the Fibre Channel port identified in the attribute.value.str field and located on the rear panel of the HSV110 controller identified in the handle field has transitioned to the FAILED state. The attribute.type field contains the value 4. The value.ul1 field contains the new state: 2 (FAILED). The value.ul2 field contains the old state: 1 (NORMAL). <P> Note that the HSV110 controller's internal identity of the affected Fibre Channel port is contained in the secondary_id field.
.1.3.6.1.4.1.232.0.13602510
Severity: Normal -- informational in nature. The state of the Disk Group identified in the handle field has transitioned to an INOPERATIVE MARKED state. The value.ul1 field contains the new Disk Group state. The value.ul2 field contains the old Disk Group state. The state values that may be found in the value.ul1 and value.ul2 fields are as follows: <UL><LI>1 = Normal <LI>2 = Disk Group with no redundancy is inoperative <LI>3 = Disk Group with parity redundancy is inoperative <LI>4 = Disk Group with mirrored redundancy is inoperative <LI>5 = Disk Group with no redundancy is inoperative, marked for re-use <LI>6 = Disk Group with parity redundancy is inoperative, marked for re-use <LI>7 = Disk Group with mirrored redundancy is inoperative, marked for re-use </UL>
.1.3.6.1.4.1.232.0.13602511
Severity: Warning -- not failed but attention recommended or required. The state of the Physical Disk Drive identified in the handle field has transitioned to the NOT PRESENT state. The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Degraded <LI>3 = Failed <LI>5 = Single Port on Fibre </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.
.1.3.6.1.4.1.232.0.13602512
Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field no longer needs attention.
.1.3.6.1.4.1.232.0.13602513
Severity: Undetermined -- more information needed to determine severity. The HSV110 controller identified in the handle field needs attention.
.1.3.6.1.4.1.232.0.13602514
Severity: Critical -- failure or failure imminent. The Blower Present flag for the '1' blower assembly located within the HSV110 controller identified in the handle field has transitioned from the PRESENT to NOT PRESENT state indicating that the blower has been removed. The secondary_id field contains the '1' blower assembly internal identifier value: 1. The value.ul1 field contains the new state of the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state of the Blower Present flag: 1 (PRESENT).
.1.3.6.1.4.1.232.0.13602515
Severity: Undetermined -- more information needed to determine severity. At least one Virtual Disk associated with the Data Replication Group identified in the handle field has transitioned to the INOPERATIVE state. The remaining Virtual Disks associated with this Data Replication Group have been forced INOPERATIVE. The value.ul1 field contains the new Data Replication Group member state: 2 (INOPERATIVE). The value.ul2 field contains the old Data Replication Group member state: 1 (OPERATIVE).
.1.3.6.1.4.1.232.0.13602516
Severity: Normal -- informational in nature. All the Virtual Disks associated with the Data Replication Group identified in the handle field have transitioned to the OPERATIVE state. The value.ul1 field contains the new Data Replication Group member state: 1 (OPERATIVE). The value.ul2 field contains the old Data Replication Group member state: 2 (INOPERATIVE).
.1.3.6.1.4.1.232.0.13602517
Severity: Normal -- informational in nature. The state of the Physical Disk Drive identified in the handle field has transitioned to the Single Port on Fibre state. The value.ul1 field contains the new state: 5 (SINGLE PORT ON FIBRE). The value.ul2 field contains the old state. The state values that may be in the value.ul2 field are as follows: <UL><LI>1 = Normal <LI>2 = Degraded <LI>3 = Failed <LI>4 = Not Present </UL>The enclosure number, bay number, and rack number where the Physical Disk Drive is located are contained in the attribute.value.u32[0], attribute.value.u32[1], attribute.value.u32[2] fields, respectively. The attribute.type field contains value 1. The rack number in the attribute.value.u32[2] field will not contain a valid value until a future release.
.1.3.6.1.4.1.232.0.13602518
Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors do not agree and the system temperature can not be accurately determined. The value.ul1 field contains the current temperature reported in celsius from I2C sensor 1, while the value.ul2 field contains the reading from I2C sensor 2.
.1.3.6.1.4.1.232.0.13602519
Severity: Normal -- informational in nature. The HSV110 controller identified in the handle field has been shutdown because the temperature sensors can not be accessed and the system temperature can not be accurately determined. The value.ul1 field contains the status from the attempted I2C access.
.1.3.6.1.4.1.232.0.136026002
Invalid data replication operation
.1.3.6.1.4.1.232.0.136026005
DR group name exceeds maximum length
.1.3.6.1.4.1.232.0.136026006
DR group created successfully
.1.3.6.1.4.1.232.0.136026007
Data replication invalid mode for DR Group create
.1.3.6.1.4.1.232.0.136026008
A duplicate DR group name exists in the specified source or destination DR group.
.1.3.6.1.4.1.232.0.136026009
Data replication invalid operation while DR Groups exist
.1.3.6.1.4.1.232.0.136026010
Data replication root folder does not exist
.1.3.6.1.4.1.232.0.136026011
DR group discarded
.1.3.6.1.4.1.232.0.136026012
Data replication unknown remote storage system
.1.3.6.1.4.1.232.0.136026013
Data replication Error. A conflicting Vdisk name exists on the remote storage system.
.1.3.6.1.4.1.232.0.136026014
Data Replication Error. Invalid Remote Vdisk Name specified.
.1.3.6.1.4.1.232.0.136026015
Data Replication Error. Remote Vdisk size cannot be modified.
.1.3.6.1.4.1.232.0.136026016
Data Replication Error. Remote Vdisk should be unpresented to proceed with the discard/detach operation.
.1.3.6.1.4.1.232.0.136027001
The element manager has successfully initialized storage system. Command issued through XML Interface.
.1.3.6.1.4.1.232.0.136027002
The element manager has successfully created a virtual disk. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027003
The element manager has successfully created a disk group. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027004
The element manager has successfully created a DRM group. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027005
The element manager has successfully created a host. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027006
The element manager has successfully created a presented unit. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027007
The element manager has successfully created a virtual disk folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027008
The element manager has successfully created a host folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027009
The element manager has successfully created a disk group folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027010
The element manager has successfully created a DRM group folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027011
The element manager has successfully created a folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027012
The element manager has successfully created a snapshot. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027013
The element manager has successfully created a snapclone. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027014
The element manager has successfully uninitialized the storage system. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027015
The element manager has successfully deleted a virtual disk. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027016
The element manager has successfully deleted a disk group. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027017
The element manager has successfully deleted a DRM group. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027018
The element manager has successfully deleted a host. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027019
The element manager has successfully deleted a presented unit. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027020
The element manager has successfully deleted a virtual disk folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027021
The element manager has successfully deleted a host folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027022
The element manager has successfully deleted a disk group folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027023
The element manager has successfully deleted a DRM group folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027024
The element manager has successfully deleted a folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027025
The element manager has successfully deleted a snapshot. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027026
The element manager has successfully modified the properties of a storage system. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027027
The element manager has successfully modified the properties of a virtual disk. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027028
The element manager has successfully modified the properties of a disk group. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027029
The element manager has successfully modified the properties of a DRM group. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027030
The element manager has successfully modified the properties of a host. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027031
The element manager has successfully modified the properties of a presented unit. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027032
The element manager has successfully modified the properties of a virtual disk folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027033
The element manager has successfully modified the properties of a host folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027034
The element manager has successfully modified the properties of a hardware root folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027035
The element manager has successfully modified the properties of a disk group folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027036
The element manager has successfully modified the properties of a DRM group folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027037
The element manager has successfully modified the properties of a DRM group root folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027038
The element manager has successfully modified the properties of a folder. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027039
The element manager has successfully modified the properties of a snapshot. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027040
The element manager has successfully modified the properties of a disk. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027041
The element manager has successfully modified the properties of a disk shelf. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027042
The element manager has successfully modified the properties of a controller. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027043
The element manager has successfully modified the properties of a controller shelf. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027044
The element manager has successfully modified the properties of a cabinet. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027045
The element manager has successfully reserved an object. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027046
The element manager has successfully released an object. Command issued through the XML Interface.
.1.3.6.1.4.1.232.0.136027047
XML cache mutex timeout.
.1.3.6.1.4.1.232.0.136027048
XML cache memory allocation error.
.1.3.6.1.4.1.232.0.136027049
XML subsystem unknown error.
.1.3.6.1.4.1.232.0.13602816
Severity: Normal -- informational in nature. The HSV110 controller identified by the node_name field has begun a resynchronization operation (i.e., a restart of the controllers in a manner that has little or no impact on host system connectivity). The information.pc field contains the program counter of resynchronization operation initiator. The information.flags field contains reboot flags value. The information.code field contains the resynchronization operation event code value.
.1.3.6.1.4.1.232.0.13603072
Severity: Normal -- informational in nature. The specified Destination Virtual Disk has successfully completed a Full Copy. The following fields are not valid: status, blocks, vda.
.1.3.6.1.4.1.232.0.13603073
Severity: Critical -- failure or failure imminent. The specified Source Virtual Disk has transitioned to the Logging state because the alternate Storage System is not accessible or the Data Replication Group is suspended. The following fields are not valid: status, blocks, vda, port, cerp_id, side.
.1.3.6.1.4.1.232.0.13603074
Severity: Critical -- failure or failure imminent. The specified Source Virtual Disk has transitioned to the Logging state because the Destination Virtual Disk is not accessible. The following fields are not valid: status, blocks, vda, port, cerp_id, side.
.1.3.6.1.4.1.232.0.13603075
Severity: Normal -- informational in nature. The specified Destination Virtual Disk has transitioned to the Merging state, because the alternate Storage System or Destination Virtual Disk is now accessible or resumed. The following fields are not valid: status, blocks, vda.
.1.3.6.1.4.1.232.0.13603076
Severity: Critical -- failure or failure imminent. A Data Replication Group has entered the Failsafe Locked state due to an inaccessible or inoperative destination. Either the Destination Virtual Disk is not accessible or a Virtual Disk in the Data Replication Group is inoperative. The following fields are not valid: status, blocks, vda, port, cerp_id, side.
.1.3.6.1.4.1.232.0.13603077
Severity: Critical -- failure or failure imminent. A Data Replication Group has entered the Failsafe Locked state due to an inoperative source. Either the Source Virtual Disk is not accessible or a Virtual Disk in the Data Replication Group is inoperative. The following fields are not valid: status, blocks, vda, port, cerp_id, side.
.1.3.6.1.4.1.232.0.13603078
Severity: Critical -- failure or failure imminent. An unrecoverable read error occurred on the specified Source Virtual Disk during the Full Copy. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy was terminated.
.1.3.6.1.4.1.232.0.13603079
Severity: Critical -- failure or failure imminent. A Full Copy terminated prior to completion. A remote copy error occurred due to an inaccessible alternate Storage System. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy will continue when the Data Replication Destination is restored.
.1.3.6.1.4.1.232.0.13603080
Severity: Critical -- failure or failure imminent. A Full Copy terminated prior to completion. A remote copy error occurred due to an inaccessible Destination Virtual Disk. The Virtual Disk address specified in the vda field indicates the first block in error. The Full Copy will continue when the Data Replication Destination is restored.
.1.3.6.1.4.1.232.0.13603081
Severity: Warning -- not failed but attention recommended or required. A Data Replication Log has been reset due to insufficient Disk Group capacity. The Data Replication Destination has been marked for a Full Copy. The following fields are not valid: status, blocks, vda, port, cerp_id, side.
.1.3.6.1.4.1.232.0.13603082
Severity: Normal -- informational in nature. A Data Replication Log has been reset due to a Data Replication Group failover. The following fields are not valid: status, blocks, vda.
.1.3.6.1.4.1.232.0.13603084
Severity: Normal -- informational in nature. A Destination Data Replication Group has successfully completed a Merge. The following fields are not valid: status, blocks, vda.
.1.3.6.1.4.1.232.0.13603087
Severity: Normal -- informational in nature. A Data Replication Group is no longer in a Failsafe Locked state. The following fields are not valid: status, blocks, vda, port, cerp_id, side.
.1.3.6.1.4.1.232.0.13603088
Severity: Normal -- informational in nature. A Destination Data Replication Group has been marked for a Full Copy. The following fields are not valid: status, blocks, vda.
.1.3.6.1.4.1.232.0.13603089
Severity: Normal -- informational in nature. A Storage System has discovered that a Data Replication Group failover has taken place. This Virtual Disk is transitioning from a Data Replication Source role to a Data Replication Destination role. The following fields are not valid: status, blocks, vda.
.1.3.6.1.4.1.232.0.13603090
Severity: Normal -- informational in nature. This Data Replication Group is transitioning from a Data Replication Destination role to a Data Replication Source role. The following fields are not valid: status, blocks, vda.
.1.3.6.1.4.1.232.0.13603093
Severity: Normal -- informational in nature. The Data Replication Path between this Site and the Alternate Site has closed, possibly due to a connection failure between the specified host port and the Alternate Site. The following fields are not valid: group_name_uuid, group_uuid, source_scvd_uuid, status, block, vda.
.1.3.6.1.4.1.232.0.13603328
Severity: Critical -- failure or failure imminent. Unrecognized event reported by a Drive Enclosure Environmental Monitoring Unit. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. The event was reported by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The content of the alarm_error_code field could not be translated into a known event. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603329
Severity: Critical -- failure or failure imminent. A physical disk drive that is not Fibre Channel compatible or cannot operate at the link rate established by the drive enclosure I/O modules was detected. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. This problem was detected during spin up of the physical disk drive installed in the drive enclosure bay identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603330
Severity: Warning -- not failed but attention recommended or required. A physical disk drive is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603331
Severity: Warning -- not failed but attention recommended or required. A physical disk drive was removed while software-activated drive locking was enabled on a drive enclosure that does not support drive locking. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The affected drive enclosure bay is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603332
Severity: Critical -- failure or failure imminent. A physical disk drive that is capable of operating at the loop link rate established by the drive enclosure I/O module was found to be running at a different rate. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The affected physical disk drive is installed in the drive enclosure bay identified in the alarm_error_code.field.en field. The Fibre Channel loop on which the problem was detected is identified by the content of the alarm_error_code.field.ec field as follows: <UL><LI>4 = loop A <LI>5 = loop B </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603379
Severity: Warning -- not failed but attention recommended or required. The AC input to a drive enclosure power supply has been lost. This makes the remaining power supply a single point of failure. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the affected power supply (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603380
Severity: Critical -- failure or failure imminent. A drive enclosure power supply is improperly installed or missing. This could affect the drive enclosure air flow and cause an over temperature condition. The operational power supply will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply shuts down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the affected power supply (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603381
Severity: Critical -- failure or failure imminent. A drive enclosure power supply component has failed. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the affected power supply (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603399
Severity: Critical -- failure or failure imminent. A drive enclosure blower is not operating properly. This could affect the drive enclosure air flow and cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the affected blower (1 or 2) is identified in the alarm_error_code.field.en field. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The blower is operating at a speed that is outside of the Drive Enclosure Environmental Monitoring Unit specified range, possibly because of a bearing problem. <LI>2 = The blower is operating at a speed that is significantly outside of the Drive Enclosure Environmental Monitoring Unit specified range, possibly because of a bearing problem. <LI>3 = The blower has stopped. NOTE: The other blower (if operational) now operates at high speed and is a single point of failure. A single blower operating at high speed can provide sufficient air flow to cool an enclosure and the elements for up to 100 hours. However, operating an enclosure at temperatures approaching an overheating threshold can damage elements and may reduce the MTBF of a specific element. Hewlett-Packard therefore recommends immediate replacement of the defective blower. <LI>4 = The power supply reported an internal blower error. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603403
Severity: Critical -- failure or failure imminent. A drive enclosure blower is improperly installed or missing. This affects the drive enclosure air flow and can cause an over temperature condition. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the affected blower (1 or 2) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603404
Severity: Critical -- failure or failure imminent. Both drive enclosure blowers are missing. This severely affects the drive enclosure air flow and can cause an over temperature condition. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that this event is preceded by a 'drive enclosure blower is improperly installed or missing' event that identifies the location of the first missing blower. The location of the second missing blower (1 or 2) is identified in the alarm_error_code.field.en field of this event. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603419
Severity: Warning -- not failed but attention recommended or required. A drive enclosure temperature sensor out of range condition has been reported by one of the drive enclosure elements. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the temperature sensor (1 through 11) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 Exhaust <LI>2 = Power Supply 2 Exhaust <LI>3 = Drive Enclosure Environmental Monitoring Unit <LI>4 = Drive Bay 1 <LI>5 = Drive Bay 2 <LI>6 = Drive Bay 3 <LI>7 = Drive Bay 4 <LI>8 = Drive Bay 5 <LI>9 = Drive Bay 6 <LI>A = Drive Bay 7 <LI>B = Drive Bay 8 <LI>C = Drive Bay 9 <LI>D = Drive Bay 10 <LI>E = Drive Bay 11 <LI>F = Drive Bay 12 <LI>10 = Drive Bay 13 <LI>11 = Drive Bay 14 </UL><P> The temperature sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element temperature is approaching, but has not reached, the high temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>2 = The element temperature is above the high temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. <LI>3 = The element temperature is approaching, but has not reached, the low temperature CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition and may reduce an element's MTBF. <LI>4 = The element temperature has reached the low temperature CRITICAL threshold. Continued operation under these conditions may result in element failure. </UL><P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603423
Severity: Critical -- failure or failure imminent. The average temperature of two of the three temperature sensor groups (i.e., Drive Enclosure Environmental Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level. The operational power supply(s) will automatically shut down after a short period of time, thereby disabling the drive enclosure. This condition remains active until either the problem is corrected, or the operational power supply(s) shut down, whichever occurs first. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. Note that in this case the content of the alarm_error_code.field.en field is undefined. <P> The actual temperature threshold values can be found in the HSV element manager GUI. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603439
Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = An internal Drive Enclosure Environmental Monitoring Unit clock error has occurred. <LI>2 = The Inter-IC (I2C) bus is not processing data and the Drive Enclosure Environmental Monitoring Unit is unable to monitor or report the status of the elements or enclosures. <LI>5 = A Backplane NVRAM error has occurred. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603441
Severity: Normal -- informational in nature. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>3 = A drive enclosure power supply was shut down. <LI>16 = The Drive Enclosure Environmental Monitoring Unit ESI data has been corrupted. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603442
Severity: Warning -- not failed but attention recommended or required. A Drive Enclosure Environmental Monitoring Unit is unable to collect data for the SCSI-3 Enclosure Services (SES) page. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603454
Severity: Warning -- not failed but attention recommended or required. Invalid data was read from a Drive Enclosure Environmental Monitoring Unit NVRAM. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603455
Severity: Warning -- not failed but attention recommended or required. An internal Drive Enclosure Environmental Monitoring Unit error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>11 = The Drive Enclosure Environmental Monitoring Unit cannot write data to the NVRAM. <LI>12 = The Drive Enclosure Environmental Monitoring Unit cannot read data from the NVRAM. <LI>13 = The Field Programmable Gate Array (FPGA) that controls the ESI bus failed to load information required for Drive Enclosure Environmental Monitoring Unit operation. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603458
Severity: Warning -- not failed but attention recommended or required. A drive enclosure's address is incorrect or the enclosure has no address. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603459
Severity: Critical -- failure or failure imminent. A Drive Enclosure Environmental Monitoring Unit has experienced a hardware failure. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>15 = Drive Enclosure Environmental Monitoring Unit hardware failure DP. <LI>18 = Drive Enclosure Environmental Monitoring Unit hardware failed BT. <LI>19 = Drive Enclosure Environmental Monitoring Unit ESI driver failure. </UL>
.1.3.6.1.4.1.232.0.13603461
Severity: Warning -- not failed but attention recommended or required. A drive enclosure power supply failed to respond to a shut down command. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the Drive Enclosure Environmental Monitoring Unit is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603469
Severity: Critical -- failure or failure imminent. A drive enclosure transceiver error has been detected. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the transceiver (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Transceiver 01 <LI>2 = Transceiver 02 <LI>3 = Transceiver 03 <LI>4 = Transceiver 04 </UL><P> The transceiver error condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The transceivers on this link are not the same type or they are incompatible with the drive enclosure I/O module. This error prevents the controller from establishing a link with the enclosure drives and eliminates the enclosure dual-loop capability. <LI>2 = The transceiver can no longer detect a data signal. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>3 = The system has detected an FC-AL bus fault involving a transceiver. This error prevents the controller from transferring data on a loop and eliminates the enclosure dual-loop capability. <LI>4 = The transceiver that was previously in this location has been removed. <LI>5 = The transceiver in the specified location has detected invalid Fibre Channel characters. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603489
Severity: Critical -- failure or failure imminent. A drive enclosure power supply voltage sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the voltage sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The voltage sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element voltage is approaching, but has not reached, the high voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element voltage is above the high voltage CRITICAL threshold. <LI>3 = The element voltage is approaching, but has not reached, the low voltage CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>4 = The element voltage has reached the low voltage CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603509
Severity: Critical -- failure or failure imminent. A drive enclosure power supply current sensor out of range condition has been reported. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the current sensor (1 through 4) is identified in the alarm_error_code.field.en field as follows: <UL><LI>1 = Power Supply 1 +5 VDC <LI>2 = Power Supply 1 +12 VDC <LI>3 = Power Supply 2 +5 VDC <LI>4 = Power Supply 2 +12 VDC </UL><P> The current sensor out of range condition is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The element current is approaching, but has not reached, the high current CRITICAL threshold. Continued operation under these conditions may result in a CRITICAL condition. <LI>2 = The element current is above the high current CRITICAL threshold. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603544
Severity: Warning -- not failed but attention recommended or required. A drive enclosure backplane invalid NVRAM read error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit.This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the drive enclosure is the affected element. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603545
Severity: Critical -- failure or failure imminent. A drive enclosure backplane error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The alarm_error_code.field.en field contains the value 1 signifying that the drive enclosure is the affected element. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>11 = Unable to write data to the NVRAM. This problem prevents communication between elements in the enclosure. <LI>12 = Unable to read data from the NVRAM. This problem prevents communication between elements in the enclosure. <LI>13 = NVRAM has not been initialized properly. This is a manufacturing error. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603549
Severity: Critical -- failure or failure imminent. A drive enclosure I/O module error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the I/O module (A (01) and B (02)) is identified in the alarm_error_code.field.en field. The cause of the improper operation is described by the content of the alarm_error_code.field.ec field as follows: <UL><LI>1 = The I/O module's Fibre Channel link speed is not supported by the backplane. This error prevents the controller from establishing a link with enclosure drives and eliminates the enclosure dual-loop capability. <LI>11 = Unable to write data to the I/O module NVRAM. <LI>12 = Unable to read data from the I/O module NVRAM. <LI>13 = The I/O module that was in this location has been removed. </UL><P> The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603550
Severity: Warning -- not failed but attention recommended or required. A drive enclosure I/O module is unable to communicate with the Drive Enclosure Environmental Monitoring Unit. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit. This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the I/O module (A (01) and B (02)) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603564
Severity: Warning -- not failed but attention recommended or required. A drive enclosure I/O module invalid NVRAM read error has occurred. The handle field contains the WWN of the drive enclosure containing the Drive Enclosure Environmental Monitoring Unit.This problem was detected by the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the rack_num field will not be valid until a future release. The location of the I/O module (A (01) or B (02)) is identified in the alarm_error_code.field.en field. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13603568
Severity: Normal -- informational in nature. The status has changed on one or more of the drive enclosures. This is an informational event triggered by the occurrence of a change in the status of a drive enclosure. This event is generated for the HSV element manager GUI and contains no user information. The content of the handle, alarm_error_code field, dencl_num, and rack_num fields have no meaning for this event. The enclosures array shows the drive enclosures available on the Fibre Channel loop pair (0 = Loop A, 1 = Loop B) identified in the loop field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
.1.3.6.1.4.1.232.0.13616896
Severity: Normal -- informational in nature. Indicated Host Fibre Channel port transitioned to link down.
.1.3.6.1.4.1.232.0.13616897
Severity: Normal -- informational in nature. Indicated Host Fibre Channel port transitioned to link failed.
.1.3.6.1.4.1.232.0.13616899
Severity: Normal -- informational in nature. An excessive number of link errors were detected on a HSV110 controller's Fibre Channel port. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. This is an informational event triggered by the occurrence of an excessive number of Tachyon chip link status errors detected within a particular link status error type. The number of occurrences of each link status error type is contained in a separate type-specific field (e.g., loss_of_signal, bad_rx_char, etc.). The HSV110 controller checks each of its Fibre Channel port's for excessive link status errors periodically.
.1.3.6.1.4.1.232.0.13616900
Severity: Warning -- not failed but attention recommended or required. A Fibre Channel port on the HSV110 controller has failed to respond. The identity of the affected Fibre Channel port is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number of the affected Fibre Channel port is contained in the port field. The peb array contains the port event block information. The peq_frz_prod_index field contains the index to the port event block in use when the Tachyon chip entered the frozen state. The peq_prod_index field contains the index to the next port event block. The peq_cons_index field contains the index to the next port event block to be acted upon.
.1.3.6.1.4.1.232.0.13616901
Severity: Normal -- informational in nature. Indicated Host Fibre Channel port transitioned to link wedged.
.1.3.6.1.4.1.232.0.13633536
Severity: Critical -- failure or failure imminent. A failure was detected during the execution of this HSV110 controller's on board diagnostics.
.1.3.6.1.4.1.232.0.13633537
Severity: Warning -- not failed but attention recommended or required. A GBIC SFF Serial ID Data check code failure was detected during the execution of this HSV110 controller's on board diagnostics.
.1.3.6.1.4.1.232.0.13633538
Severity: Critical -- failure or failure imminent. A battery assembly failure was detected during the execution of this HSV110 controller's on board diagnostics.
.1.3.6.1.4.1.232.0.13633539
Severity: Critical -- failure or failure imminent. A battery assembly failure was detected during the execution of this HSV110 controller's on board diagnostics.
.1.3.6.1.4.1.232.0.13633540
Severity: Critical -- failure or failure imminent. A battery assembly communication failure was detected during the execution of this HSV110 controller's on board diagnostics.
.1.3.6.1.4.1.232.0.13633541
Severity: Critical -- failure or failure imminent. A battery assembly communication failure was detected during the execution of this HSV110 controller's on board diagnostics.
.1.3.6.1.4.1.232.0.13633542
Severity: Critical -- failure or failure imminent. A soft cache memory ECC error or indication of low battery voltage was detected during the execution of this HSV110 controller's on board diagnostics.