sCellEventTrap_9_2c
CPQHSV110V3-MIB ·
.1.3.6.1.4.1.232.0.13602348
Object
notification
Severity: Warning -- not failed but attention recommended or required. The state of a battery assembly within the HSV110 controller identified in the handle field has transitioned to the Battery System Hold-up Time is zero hours state. The value.ul1 field contains the new state 5: (Battery System Hold-up Time is zero hours). The value.ul2 field contains the old state. The state values that may be found in the value.ul2 field are as follows: <UL><LI>1 = Battery System Hold-up Time is greater than 96 hours <LI>3 = Battery System Hold-up Time is greater than 0 and less than 96 hours <LI>5 = Battery System Hold-up Time is zero hours </UL>
Context
- MIB
- CPQHSV110V3-MIB
- OID
.1.3.6.1.4.1.232.0.13602348- Type
- notification
- Status
- current
- Parent
- compaq
Net-SNMP examples
How SNMP and these commands workNotifications are emitted by an agent; they cannot be read with snmpget or walked.
Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'CPQHSV110V3-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQHSV110V3-MIB::sCellEventTrap_9_2c'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQHSV110V3-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQHSV110V3-MIB::sCellEventTrap_9_2c'
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.