sCellEventTrap_6_30
CPQHSV110V3-MIB ·
.1.3.6.1.4.1.232.0.13601584
Object
notification
Severity: Critical -- failure or failure imminent. A HSV110 controller has detected only one port of all Fibre Channel devices in an enclosure. These Fibre Channel devices have entered the Single Port on Fibre state which should be corrected as soon as possible. The identity of the Fibre Channel device enclosure is contained in the device field. The Fibre Channel port still able to communicate with the Fibre Channel device is contained in the cerp_id field. The HSV110 controller internal Fibre Channel port number able to communicate with the Fibre Channel device is contained in the port field. The Fibre Channel port unable to communicate with the Fibre Channel device is contained in the missing_cerp_id field. The HSV110 controller internal Fibre Channel port number unable to communicate with the Fibre Channel device is contained in the missing_port field. The al_pa and bay fields are invalid. The location of the Fibre Channel enclosure is determined by the content of the dencl_num field as follows: <UL><LI>If dencl_num is less than 99, the location is as indicated by the content of the rack_num and dencl_num fields. <LI>If dencl_num is equal to 99, the location is unknown. Note that the content of the rack_num field is undefined in this case. <LI>If dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the rack_num and dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. The identity contained in the device field should be used to confirm the last known location values. </UL>Note that the content of the rack_num field will not be valid until a future release. Note also that in this case the content of the fed_class, and num_times fields is undefined. The enclosures array shows the drive enclosures available on the Fibre Channel port identified in the cerp_id field. The location of an available drive enclosure is determined by the content of the enclosures.dencl_num field as follows: <UL><LI>If enclosures.dencl_num is less than 99, the location is as indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. <LI>If enclosures.dencl_num is equal to 99, the enclosures array entry is not used. Note that the content of the enclosures.rack_num field is undefined in this case. <LI>If enclosures.dencl_num is greater than 99, the HSV110 controller does not have proof of the current location but the last known location is indicated by the content of the enclosures.rack_num and enclosures.dencl_num fields. Subtract 100 from the content of those fields to determine the actual last known location. If there have been no configuration changes, the last known location values will be accurate. </UL>Note that the content of the enclosures.rack_num field will not be valid until a future release.
Context
- MIB
- CPQHSV110V3-MIB
- OID
.1.3.6.1.4.1.232.0.13601584- Type
- notification
- Status
- current
- Parent
- compaq
Net-SNMP examples
How SNMP and these commands workNotifications are emitted by an agent; they cannot be read with snmpget or walked.
Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'CPQHSV110V3-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQHSV110V3-MIB::sCellEventTrap_6_30'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQHSV110V3-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQHSV110V3-MIB::sCellEventTrap_6_30'
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.