sCellEventTrap_4_3

CPQHSV110V3-MIB · .1.3.6.1.4.1.232.0.13601027

Object

notification
Severity: Critical -- failure or failure imminent. An unexpected event occurred while a termination event was being processed. The value contained in the uei.type field describes the event as follows: <UL><LI>0 = Unrecognized Unexpected Event code. <LI>1 = Power failure before initialization could complete. <LI>2 = Recursive termination before initialization could complete. <LI>3 = Terminated during the first part post-termination preparation. <LI>4 = Terminated during the load of the G3 Glue registers. <LI>5 = Terminated during the second part post-termination preparation. <LI>6 = Terminated during event report block load. <LI>7 = Terminated during initialization of all hardware components and software data structures in preparation for restart. <LI>8 = Terminated during execution of an unrecognized post-termination operation (premature). <LI>9 = Power failure during execution of a post-termination operation. <LI>A = No good entries found in Termination Event Array. (Note that this condition is expected following the first boot of a newly manufactured HSV110 controller. In that case this event can be safely ignored; no action is necessary.) <LI>B = The EDC of one or more Termination Event Array entries is bad. <LI>C = Termination Event Array entry control block revision is different. <LI>D = Termination Event Array entry information block revision is different. <LI>E = Termination Event Array entry up time value is greater than the system's up time value. <LI>F = Termination Event Array entry up time value is less than the previous entry's up time value. <LI>10= Termination Event Array entry sequence number value is less than the previous entry's sequence number value. <LI>11= Detected an unrecognized dump/restart control code. <LI>12= Failed to terminate the entity dump loop. <LI>13= Unexpected dump entity size. <LI>14= Unexpected Event Log Packet processing stage code. <LI>15= Number of Termination Parameters supplied not equal to maximum allowed as required. </UL><P> The post-termination operation being performed at the time the unexpected event occurred is contained in the uei.pto field. Note: The lteihd and lter fields may not describe the event that caused the HSV110 controller to terminate operation depending on how far termination processing got before the unexpected event occurred.

Context

MIB
CPQHSV110V3-MIB
OID
.1.3.6.1.4.1.232.0.13601027
Type
notification
Status
current
Parent
compaq

Notifications are emitted by an agent; they cannot be read with snmpget or walked.

Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'CPQHSV110V3-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQHSV110V3-MIB::sCellEventTrap_4_3'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CPQHSV110V3-MIB' -M '/opt/observium/mibs/hp:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CPQHSV110V3-MIB::sCellEventTrap_4_3'

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.