sysTimeOfDayType

CM-SYSTEM-MIB · .1.3.6.1.4.1.2544.1.12.2.1.5.3

Object

scalar r/w TimeOfDayType
This object provides ability to configure System Time of Day source.
This can be local, ntp or ptp. 
Before setting sysTimeOfDayType the f3PtpSysTimeOfDayClock object must be
set to configure PTP Telecom Slave object to be used as Clock source.

Context

MIB
CM-SYSTEM-MIB
OID
.1.3.6.1.4.1.2544.1.12.2.1.5.3
Type
scalar
Access
readwrite
Status
current
Parent
cmSysModeObjects
Groups
1

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CM-SYSTEM-MIB' -M '/opt/observium/mibs/adva:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CM-SYSTEM-MIB::sysTimeOfDayType.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CM-SYSTEM-MIB' -M '/opt/observium/mibs/adva:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CM-SYSTEM-MIB::sysTimeOfDayType'

Syntax

Source
TimeOfDayType
Base type
Enumeration

Values & Constraints

Type Values
1local
2ntp
3ptp
4timeclock

Conformance