cswSwitchNumNextReload
CISCO-STACKWISE-MIB ·
.1.3.6.1.4.1.9.9.500.1.2.1.1.2
Object
This object contains the cswSwitchNumCurrent to be
used at next reload. The maximum value for this object is
defined by the cswMaxSwitchNum object.
Note: This object will contain 0 and cannot be set if the
cswSwitchState value is other than 'ready'.
Context
- MIB
- CISCO-STACKWISE-MIB
- OID
.1.3.6.1.4.1.9.9.500.1.2.1.1.2- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- cswSwitchInfoEntry
- Groups
- 3
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-STACKWISE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-STACKWISE-MIB::cswSwitchNumNextReload'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CISCO-STACKWISE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-STACKWISE-MIB::cswSwitchNumNextReload.<entPhysicalIndex>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CISCO-STACKWISE-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CISCO-STACKWISE-MIB::cswSwitchNumNextReload'
Syntax
- Source
- CswSwitchNumberOrZero
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Conformance
Compliance refinements
cswStackWiseMIBCompliance
readonly
Write access is not required.
cswStackWiseMIBComplianceRev3