lineLength
CISCO-MGX82XX-DSX1-MIB ·
.1.3.6.1.4.1.351.110.4.3.1.1.1.1.6
Object
column
r/w
Enumeration
This is not a standard RFC 1407 DS1 variable, it is
specific to BASIS implementation. It specifies the line length:
1 - 0 to 110 ft (T1 line only)
2 - 110 to 220 ft (T1 line only)
3 - 220 to 330 ft (T1 line only)
4 - 330 to 440 ft (T1 line only)
5 - 440 to 550 ft (T1 line only)
6 - 550 to 660 ft (T1 line only)
7 - greater than 660 ft (T1 line only)
8 - 75 ohms (E1 line only (BNC))
9 - 120 ohms (E1 line only (DB-15))
The default value for T1 is 1, for E1, if the connector
type is DB15 then the default is 9, if BNC, it's 8.
For FRSM-2CT3, the line length of DS1 has no meaning
as there are no physical DS1 lines. So, for this
card, the value is set to notRequired (16).
Context
- MIB
- CISCO-MGX82XX-DSX1-MIB
- OID
.1.3.6.1.4.1.351.110.4.3.1.1.1.1.6- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- dsx1CnfGrpEntry
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | lineLength0To110Feet |
2 | lineLength110To220Feet |
3 | lineLength220To330Feet |
4 | lineLength330To440Feet |
5 | lineLength440To550Feet |
6 | lineLength550To660Feet |
7 | lineLength660FeetPlus |
8 | lineLength-75-Ohm |
9 | lineLength-120-Ohm |
10 | lineLength0To131Feet |
11 | lineLength131To262Feet |
12 | lineLength262To393Feet |
13 | lineLength393To524Feet |
14 | lineLength524To655Feet |
15 | lineLength655FeetPlus |
16 | notRequired |