cldBandSelectCycleThreshold

CISCO-LWAPP-DOT11-MIB · .1.3.6.1.4.1.9.9.612.1.1.9.3

Object

scalar r/w milliseconds Integer32
This object specifies time threshold for a new scanning
mobile station period. Mobile station cycle counter will 
increment only if mobile station scans same channel any 
time after cldBandSelectCycleThreshold is passed.
          
For example, if a mobile station is scanning a channel after
every 150 milliseconds and cycle threshold value is
configures as 200, then cycle count will be incremented
after 300 seconds. But if mobile station is scanning after every
250 milliseconds, then mobile station count will be incremented
after 250 milliseconds.

Context

MIB
CISCO-LWAPP-DOT11-MIB
OID
.1.3.6.1.4.1.9.9.612.1.1.9.3
Type
scalar
Access
readwrite
Status
current
Units
milliseconds
Parent
cldBandSelect
Siblings
6

Syntax

milliseconds Integer32

Values & Constraints

Object Constraints
range: 1-1000

Related Objects

Sibling Objects