cldBandSelectCycleThreshold
CISCO-LWAPP-DOT11-MIB ·
.1.3.6.1.4.1.9.9.612.1.1.9.3
Object
scalar r/w
millisecondsInteger32
This object specifies time threshold for a new scanning
mobile station period. Mobile station cycle counter will
increment only if mobile station scans same channel any
time after cldBandSelectCycleThreshold is passed.
For example, if a mobile station is scanning a channel after
every 150 milliseconds and cycle threshold value is
configures as 200, then cycle count will be incremented
after 300 seconds. But if mobile station is scanning after every
250 milliseconds, then mobile station count will be incremented
after 250 milliseconds.
Context
- MIB
- CISCO-LWAPP-DOT11-MIB
- OID
.1.3.6.1.4.1.9.9.612.1.1.9.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Units
- milliseconds
- Parent
- cldBandSelect
- Groups
- 1
Net-SNMP examples
How SNMP and these commands workScalars have one instance, identified by the .0 suffix.
Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CISCO-LWAPP-DOT11-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-LWAPP-DOT11-MIB::cldBandSelectCycleThreshold.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CISCO-LWAPP-DOT11-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CISCO-LWAPP-DOT11-MIB::cldBandSelectCycleThreshold'
Syntax
millisecondsInteger32
Values & Constraints
Object Constraints
range: 1-1000
Conformance
Member of