ciscoICsuDsuSw56kDialingStatus

CISCO-ICSUDSU-MIB · .1.3.6.1.4.1.9.9.44.1.3.2.1.1

Object

column Enumeration
This variable indicates the dialing status of units using 
switched connections.
idle - on-hook and no call in progress.
dialing - dialing a number.
onLine - Online passing data.
noWinkFromSwitch - No wink from switch (cleared after 5 
     seconds).  Wink is a DC signalling method in which the 
     polarity of the line is temporarily reversed and then 
     returned to its original polarity as an acknowledgement. 
numberBusy - Number is busy (cleared after 5 seconds).
noAnswer - No answer. (cleared after 5 seconds).

Context

MIB
CISCO-ICSUDSU-MIB
OID
.1.3.6.1.4.1.9.9.44.1.3.2.1.1
Type
column
Access
readonly
Status
current
Parent
ciscoICsuDsuSw56kLineStatusEntry
Table
ciscoICsuDsuSw56kLineStatusTable
Siblings
6

Syntax

Enumeration

Values & Constraints

Enumerated Values
1idle
2dialing
3online
4noWinkFromSwitch
5numberBusy
6noAnswer