cfmAlarmHistorySize
CISCO-FLOW-MONITOR-MIB ·
.1.3.6.1.4.1.9.9.692.1.6.1
Object
scalar
r/w
Unsigned32
This object specifies the maximum number of rows the cfmAlarmHistoryTable can contain at any given time. If the device raises or clears an alarm and the cfmAlarmHistoryTable already contains a number of rows equal to the value of this object, then it destroys the oldest row before creating a new one.
Context
- MIB
- CISCO-FLOW-MONITOR-MIB
- OID
.1.3.6.1.4.1.9.9.692.1.6.1- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- cfmAlarmHistory
- Siblings
- 2
Syntax
Unsigned32
Values & Constraints
Object Constraints
range: 1-4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| cfmAlarmHistoryLastId This object indicates the value of cfmAlarmHistoryId
corresponding to the last row created in the
cfmAlarmHistoryTable. | scalar | Unsigned32 | .1.3.6.1.4.1.9.9.692.1.6.2 |
| cfmAlarmHistoryTable This table lists a history of the changes in the state of alarm
conditions monitored by the device. | table | - | .1.3.6.1.4.1.9.9.692.1.6.3 |