CISCO-FLOW-MONITOR-MIB Table View

Table-centric layout grouping table, row, and column objects.

Tables
13
Rows
13
Columns
109
.1.3.6.1.4.1.9.9.692.1.1.1 · 1 row entry · 13 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmFlowMonitorTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmFlowMonitorTable'
This table lists the flow monitors contained by the device.
cfmFlowMonitorEntry row .1.3.6.1.4.1.9.9.692.1.1.1.1
An entry describes a flow monitor, which represents a hardware
or software entity that classifies traffic flows, monitors flow
data, and periodically computes flow metrics.

A simple device may only support …
Column Syntax OID
This object indicates an arbitrary integer-value that uniquely
identifies the flow monitor. Observe that the value assigned to
a flow monitor does not necessarily persist across restarts or
the
removal-insertion of a p…
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorIdentifier
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.1.1.1.1
This object indicates a human-readable description for the flow
monitor.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.1.1.1.2
This object indicates the capabilities of the flow monitor.
Specifically, the value of this column indicates a '1' for each
set of flow metrics the flow monitor is capable of measuring.
CISCO-FLOW-MONITOR-TC-MIBFlowMetrics
Type Values:
0mdi
1rtp
2ipCbr
.1.3.6.1.4.1.9.9.692.1.1.1.1.3
This object indicates the number of traffic flows currently
monitored by the flow monitor.
traffic flowsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.1.1.1.4
This object indicates the conditions profile that contains the
descriptions of the standing conditions monitored for the flow
monitor.

If the flow monitor does not have an associated conditions
profile, t…
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditionsProfileOrZero
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.1.1.1.5
This object indicates the current standing conditions for the
flow monitor.

If the flow monitor does not have an associated conditions
profile, then the value of this column must be the null string.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditions
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.1.1.1.6
This object indicates the current alarm conditions for the flow
monitor.

If the flow monitor does not have an associated conditions
profile, then the value of this column must be the null string.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditions
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.1.1.1.7
This object indicates the high severity alarm condition
currently raised by the flow monitor and the traffic flows
monitored by the flow monitor.

If no alarm is raised for the flow monitor and the traffic…
CISCO-TCCiscoAlarmSeverity
Type Values:
1cleared
2indeterminate
3critical
4major
5minor
6warning
7info
.1.3.6.1.4.1.9.9.692.1.1.1.1.8
This object indicates the number of alarm conditions with a
critical severity currently raised for traffic flows monitored
by the flow monitor.
alarmsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.1.1.1.9
This object indicates the number of alarm conditions with a
major severity currently raised for traffic flows monitored by
the flow monitor.
alarmsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.1.1.1.10
This object indicates the number of alarm conditions with a
minor severity currently raised for traffic flows monitored by
the flow monitor.
alarmsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.1.1.1.11
This object indicates the number of alarm conditions with a
warning severity currently raised for traffic flows monitored by
the flow monitor.
alarmsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.1.1.1.12
This object indicates the number of alarm conditions with a
informational severity currently raised for traffic flows
monitored by the flow monitor.
alarmsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.1.1.1.13

cfmFlowTable

table
.1.3.6.1.4.1.9.9.692.1.2.1 · 1 row entry · 13 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmFlowTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmFlowTable'
This table lists the traffic flows monitored by each flow
monitor supported by the device.
          
This table has an expansion dependent relationship on the
cfmFlowMonitorTable, containing zero or more rows for each flow
monitor.
cfmFlowEntry row .1.3.6.1.4.1.9.9.692.1.2.1.1
An entry describes a traffic flow monitored by a flow monitor.

The device creates a row in the cfmFlowTable when a flow monitor
starts monitoring a traffic flow. Likewise, the device
destroys a row in the …
Column Syntax OID
This object indicates an arbitrary integer-value that uniquely
identifies a traffic flow in the scope of the flow monitor that
learned it. Observe that the value assigned to a flow does not
necessarily persist across r…
CISCO-FLOW-MONITOR-TC-MIBFlowIdentifier
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.2.1.1.1
This object indicates a human-readable description of the
traffic flow.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.2.1.1.2
This object indicates a reference to a row in another table
containing additional data relating to the traffic flow.
SNMPv2-TCRowPointer
Description:
Represents a pointer to a conceptual row. The value is the
name of the instance of the first accessible columnar object
in the conceptual row.

For example, ifIndex.3 would point to the 3rd row in the
ifTable…
.1.3.6.1.4.1.9.9.692.1.2.1.1.3
This object indicates the value of sysUpTime when the row was
created.
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.4.1.9.9.692.1.2.1.1.4
This object indicates the value of sysUpTime on the most
recent occasion at which any one or more of counters associated
with the traffic flow suffered a discontinuity (e.g., process
restart or failover event).
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.4.1.9.9.692.1.2.1.1.5
This object indicates the expiration interval for the traffic
flow. If the flow monitor receives no packets for the traffic
flow in this interval, then it expires the flow; that is, it
stops monitoring the traffic and …
secondsUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.9.9.692.1.2.1.1.6
This object indicates the direction of the traffic flow where
the flow monitor collects data:

'unknown'
The SNMP entity does not know the direction of the
traffic flow at the point the…
Enumeration
Enumerated Values:
1unknown
2ingress
3egress
.1.3.6.1.4.1.9.9.692.1.2.1.1.7
This object specifies the desired state of the traffic flow:

'enabled'
The corresponding flow monitor is collecting data and
computing metrics for the traffic flow.

'disabled'
T…
Enumerationr/w
Enumerated Values:
1enabled
2disabled
3expire
.1.3.6.1.4.1.9.9.692.1.2.1.1.8
This object indicates the operational state of the traffic
flow:

'enabled'
The corresponding flow monitor is actively monitoring
the traffic flow.

'disabled'
Enumeration
Enumerated Values:
1enabled
2disabled
.1.3.6.1.4.1.9.9.692.1.2.1.1.9
This object indicates the type of port that receives the
traffic for this traffic flow.
CISCO-FLOW-MONITOR-TC-MIBFlowPointType
Type Values:
1other
2unknown
3none
4interface
5dot1qVlan
.1.3.6.1.4.1.9.9.692.1.2.1.1.10
This object identifies the port that receives the traffic for
this
traffic flow.
CISCO-FLOW-MONITOR-TC-MIBFlowPointIdentifier
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.2.1.1.11
This object indicates the type of port that transmits the
traffic for this traffic flow.
CISCO-FLOW-MONITOR-TC-MIBFlowPointType
Type Values:
1other
2unknown
3none
4interface
5dot1qVlan
.1.3.6.1.4.1.9.9.692.1.2.1.1.12
This object identifies the port that transmits the traffic for
this traffic flow.
CISCO-FLOW-MONITOR-TC-MIBFlowPointIdentifier
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.2.1.1.13
.1.3.6.1.4.1.9.9.692.1.2.3 · 1 row entry · 3 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmFlowL2VlanTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmFlowL2VlanTable'
This table contains additional data relating to the L2 VLAN
carrying traffic flows monitored by flow monitors.
          
This table has a sparse dependent relationship on the
cfmFlowTable.
cfmFlowL2VlanEntry row .1.3.6.1.4.1.9.9.692.1.2.3.1
An entry describes data relating to the L2 VLAN carrying the
corresponding traffic flow.

A device creates a row in the cfmFlowL2VlanTable when a flow
monitor has data relating to the L2 VLAN carrying a
corr…
Column Syntax OID
This object indicates a reference to a row in another table
containing additional data relating to the corresponding traffic
flow.
SNMPv2-TCRowPointer
Description:
Represents a pointer to a conceptual row. The value is the
name of the instance of the first accessible columnar object
in the conceptual row.

For example, ifIndex.3 would point to the 3rd row in the
ifTable…
.1.3.6.1.4.1.9.9.692.1.2.3.1.1
This object indicates the tag associated with the VLAN
carrying the corresponding traffic flow.
Q-BRIDGE-MIBVlanId
Type Constraints:
range: 1..4094
.1.3.6.1.4.1.9.9.692.1.2.3.1.2
This object indicates the layer 2 COS assigned to the
corresponding traffic flow.
CISCO-TCLayer2Cos
Type Constraints:
range: 0..7
.1.3.6.1.4.1.9.9.692.1.2.3.1.3
.1.3.6.1.4.1.9.9.692.1.2.5 · 1 row entry · 7 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmFlowIpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmFlowIpTable'
This table contains additional data relating to the IP carrying
the corresponding traffic flow.
          
This table has a sparse dependent relationship on the
cfmFlowTable.
cfmFlowIpEntry row .1.3.6.1.4.1.9.9.692.1.2.5.1
An entry describes data relating to the IP carrying the
corresponding traffic flow.

A device creates a row in the cfmFlowIpTable when the flow
monitor has data relating to the IP carrying the corresponding
Column Syntax OID
This object indicates a reference to a row in another table
containing additional data relating to the corresponding traffic
flow.
SNMPv2-TCRowPointer
Description:
Represents a pointer to a conceptual row. The value is the
name of the instance of the first accessible columnar object
in the conceptual row.

For example, ifIndex.3 would point to the 3rd row in the
ifTable…
.1.3.6.1.4.1.9.9.692.1.2.5.1.1
This object indicates the type of IP address indicated by the
corresponding instances of cfmFlowIpAddrSrc and
cfmFlowIpAddrDst.
INET-ADDRESS-MIBInetAddressType
Type Values:
0unknown
1ipv4
2ipv6
3ipv4z
4ipv6z
16dns
25l2vpn
.1.3.6.1.4.1.9.9.692.1.2.5.1.2
This object indicates the source IP address of the
corresponding traffic flow.
INET-ADDRESS-MIBInetAddress
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.2.5.1.3
This object indicates the destination IP address of the
corresponding traffic flow.
INET-ADDRESS-MIBInetAddress
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.2.5.1.4
This object indicates whether the corresponding instances of
cfmFlowIpTrafficClass and cfmFlowIpHopLimit are valid.
Bits
Enumerated Values:
0trafficClass
1hopLimit
.1.3.6.1.4.1.9.9.692.1.2.5.1.5
This object indicates the traffic class of the corresponding
traffic flow.

If version 4 of the IP carries the traffic flow, then the value
of this column corresponds to the 'Type of Service' field of the
Unsigned32
Constraints:
range: 0-255
.1.3.6.1.4.1.9.9.692.1.2.5.1.6
This object indicates the hop limit of the corresponding
traffic flow.

If version 4 of the IP carries the traffic flow, then the value
of this column corresponds to the 'Time to Live' field of the IP
head…
Unsigned32
Constraints:
range: 0-255
.1.3.6.1.4.1.9.9.692.1.2.5.1.7
.1.3.6.1.4.1.9.9.692.1.2.7 · 1 row entry · 3 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmFlowUdpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmFlowUdpTable'
This table contains additional data relating to the UDP
carrying the corresponding traffic flow.
          
This table has a sparse dependent relationship on the
cfmFlowTable.
cfmFlowUdpEntry row .1.3.6.1.4.1.9.9.692.1.2.7.1
An entry describes data relating to the UDP carrying the
corresponding traffic flow.

A device creates a row in the cfmFlowUdpTable when the flow
monitor has data relating to the UDP carrying the correspondi…
Column Syntax OID
This object indicates a reference to a row in another table
containing additional data relating to the corresponding traffic
flow.
SNMPv2-TCRowPointer
Description:
Represents a pointer to a conceptual row. The value is the
name of the instance of the first accessible columnar object
in the conceptual row.

For example, ifIndex.3 would point to the 3rd row in the
ifTable…
.1.3.6.1.4.1.9.9.692.1.2.7.1.1
This object indicates the source UDP port number of the
corresponding traffic flow.
INET-ADDRESS-MIBInetPortNumber
Type Constraints:
range: 0..65535
.1.3.6.1.4.1.9.9.692.1.2.7.1.2
This object indicates the destination UDP port number of the
corresponding traffic flow.
INET-ADDRESS-MIBInetPortNumber
Type Constraints:
range: 0..65535
.1.3.6.1.4.1.9.9.692.1.2.7.1.3
.1.3.6.1.4.1.9.9.692.1.2.9 · 1 row entry · 3 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmFlowTcpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmFlowTcpTable'
This table contains additional data relating to the TCP
carrying the corresponding traffic flow.
          
This table has a sparse dependent relationship on the
cfmFlowTable.
cfmFlowTcpEntry row .1.3.6.1.4.1.9.9.692.1.2.9.1
An entry describes data relating to the TCP carrying the
corresponding traffic flow.

A device creates a row in the cfmFlowTcpTable when the flow
monitor has data relating to the TCP carrying the correspondi…
Column Syntax OID
This object indicates a reference to a row in another table
containing additional data relating to the corresponding traffic
flow.
SNMPv2-TCRowPointer
Description:
Represents a pointer to a conceptual row. The value is the
name of the instance of the first accessible columnar object
in the conceptual row.

For example, ifIndex.3 would point to the 3rd row in the
ifTable…
.1.3.6.1.4.1.9.9.692.1.2.9.1.1
This object indicates the source TCP port number of the
corresponding traffic flow.
INET-ADDRESS-MIBInetPortNumber
Type Constraints:
range: 0..65535
.1.3.6.1.4.1.9.9.692.1.2.9.1.2
This object indicates the destination TCP port number of the
corresponding traffic flow.
INET-ADDRESS-MIBInetPortNumber
Type Constraints:
range: 0..65535
.1.3.6.1.4.1.9.9.692.1.2.9.1.3
.1.3.6.1.4.1.9.9.692.1.2.11 · 1 row entry · 4 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmFlowRtpTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmFlowRtpTable'
This table contains additional data relating to the RTP
carrying the corresponding traffic flow.
          
This table has a sparse dependent relationship on the
cfmFlowTable.
cfmFlowRtpEntry row .1.3.6.1.4.1.9.9.692.1.2.11.1
An entry describes data relating to the RTP carrying the
corresponding traffic flow.

A device creates a row in the cfmFlowRtpTable when the flow
monitor has data relating to the RTP carrying the correspondi…
Column Syntax OID
This object indicates a reference to a row in another table
containing additional data relating to the corresponding traffic
flow.
SNMPv2-TCRowPointer
Description:
Represents a pointer to a conceptual row. The value is the
name of the instance of the first accessible columnar object
in the conceptual row.

For example, ifIndex.3 would point to the 3rd row in the
ifTable…
.1.3.6.1.4.1.9.9.692.1.2.11.1.1
This object indicates the RTP version of the corresponding
traffic flow.
Unsigned32
Constraints:
range: 0-3
.1.3.6.1.4.1.9.9.692.1.2.11.1.2
This object indicates the RTP synchronized source (SSRC) of
the corresponding traffic flow.
Unsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.9.9.692.1.2.11.1.3
This object indicates the RTP payload type of the
corresponding traffic flow.
Unsigned32
Constraints:
range: 0-127
.1.3.6.1.4.1.9.9.692.1.2.11.1.4
.1.3.6.1.4.1.9.9.692.1.3.1 · 1 row entry · 15 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmFlowMetricsTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmFlowMetricsTable'
This table contains aggregate metrics and data relating to the
collection of metrics for the traffic flows monitored by each of
the flow monitors supported by the device.
          
This table has a sparse dependent relationship on the
cfmFlowTable, containing a row for each row in the cfmFlowTable
for which the device is actively monitoring.
cfmFlowMetricsEntry row .1.3.6.1.4.1.9.9.692.1.3.1.1
An entry contains aggregate metrics and data relating to the
collection of metrics for a corresponding traffic flow.

The device creates a row in the cfmFlowMetricsTable when a flow
monitor starts monitoring…
Column Syntax OID
This object indicates the metrics collected by the
corresponding flow monitor for the corresponding traffic flow.
CISCO-FLOW-MONITOR-TC-MIBFlowMetrics
Type Values:
0mdi
1rtp
2ipCbr
.1.3.6.1.4.1.9.9.692.1.3.1.1.1
This object indicates the length of the measurement interval
for the corresponding traffic flow. The flow monitor computes
the collected metrics for the corresponding traffic flow with a
frequency equal to the inverse …
secondsUnsigned32
Constraints:
range: 1-3600
.1.3.6.1.4.1.9.9.692.1.3.1.1.2
This object indicates the maximum number of measurement
intervals for which the corresponding flow monitor maintains
metrics for the corresponding traffic flow.

If the value of this column is '0', then th…
intervalsUnsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.9.9.692.1.3.1.1.3
This object indicates the time that has elapsed since the
beginning of the current measurement interval.
secondsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.3.1.1.4
This object indicates the number of measurement intervals for
which data has been collected.
intervalsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.3.1.1.5
This object indicates the number of measurement intervals in
the set of collected measurement intervals that contain invalid
data.
intervalsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.3.1.1.6
This object indicates the conditions profile that contains the
descriptions of the standing conditions monitored for the
traffic flow.

If the flow does not have an associated conditions profile,
then the …
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditionsProfileOrZero
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.3.1.1.7
This object indicates the current standing conditions for the
corresponding traffic flow.

If the flow does not have an associated conditions profile, then
the value of this column must be the null string.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditions
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.3.1.1.8
This object indicates the current alarm conditions for the
corresponding traffic flow.

If the flow does not have an associated conditions profile, then
the value of this column must be the null string.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditions
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.3.1.1.9
This object indicates the highest severity alarm currently
raised for the corresponding traffic flow.

If no alarm is raised for the corresponding traffic flow, then
the value of this column is 'cleared'.
CISCO-TCCiscoAlarmSeverity
Type Values:
1cleared
2indeterminate
3critical
4major
5minor
6warning
7info
.1.3.6.1.4.1.9.9.692.1.3.1.1.10
This object indicates the total number of packets processed by
the corresponding flow monitor for the corresponding traffic
flow.
packetsSNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.9.9.692.1.3.1.1.11
This object indicates the total number of octets contained by
the packets processed by the corresponding flow monitor for the
corresponding traffic flow.
octetsSNMPv2-SMICounter64
Type Constraints:
range: 0..18446744073709551615
.1.3.6.1.4.1.9.9.692.1.3.1.1.12
This object indicates the units for the corresponding instance
of cfmFlowMetricsBitRate.
CISCO-FLOW-MONITOR-TC-MIBFlowBitRateUnits
Type Values:
1bps
2kbps
3mbps
4gbps
.1.3.6.1.4.1.9.9.692.1.3.1.1.13
This object indicates the average bit rate at which the
corresponding flow monitor is processing data for the
corresponding traffic flow. This value is cumulative over the
lifetime of the traffic flow.
SNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.3.1.1.14
This object indicates the average packet rate at which the
corresponding flow monitor is processing data for the
corresponding traffic flow. This value is cumulative over the
lifetime of the traffic flow.
packets per secondSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.3.1.1.15
.1.3.6.1.4.1.9.9.692.1.3.3 · 1 row entry · 11 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmFlowMetricsIntTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmFlowMetricsIntTable'
This table contains historic metrics for the traffic flows
monitored by each of the flow monitors supported by the device.
          
This table has an expansion dependent relationship on the
cfmFlowMetricsTable, containing zero or more rows for each
traffic flow.
cfmFlowMetricsIntEntry row .1.3.6.1.4.1.9.9.692.1.3.3.1
An entry describes metrics collected for a previous
measurement interval for a corresponding traffic flow.
Column Syntax OID
This object indicates the interval number identifying the
measurement interval. The measurement interval identified by
the value '1' represents the most recent measurement interval,
and the interval identified by the v…
Unsigned32
Constraints:
range: 1-4294967295
.1.3.6.1.4.1.9.9.692.1.3.3.1.1
This object indicates whether the data for the measurement
interval is valid.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.9.9.692.1.3.3.1.2
This object indicates the value of sysUpTime when the
measurement interval was captured.
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.4.1.9.9.692.1.3.3.1.3
This object indicates which standing conditions were asserted
at least once during the measurement interval for the
corresponding traffic flow.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditions
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.3.3.1.4
This object indicates which alarm conditions were raised at
least once during the measurement interval for the
corresponding traffic flow.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditions
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.3.3.1.5
This object indicates the highest severity alarm raised during
the measurement interval for the corresponding traffic flow.

If no alarm was raised during the measurement interval for the
corresponding tra…
CISCO-TCCiscoAlarmSeverity
Type Values:
1cleared
2indeterminate
3critical
4major
5minor
6warning
7info
.1.3.6.1.4.1.9.9.692.1.3.3.1.6
This object indicates the number of packets processed by the
corresponding flow monitor for the corresponding traffic
flow during the measurement interval.
packetsCISCO-REPORT-INTERVAL-TC-MIBReportIntervalCount .1.3.6.1.4.1.9.9.692.1.3.3.1.7
This object indicates the number of octets contained by the
packets processed by the corresponding flow monitor for the
corresponding traffic flow during the measurement interval.
octetsCISCO-REPORT-INTERVAL-TC-MIBReportIntervalCount .1.3.6.1.4.1.9.9.692.1.3.3.1.8
This object indicates the units for the corresponding instance
of cfmFlowMetricsIntBitRate.
CISCO-FLOW-MONITOR-TC-MIBFlowBitRateUnits
Type Values:
1bps
2kbps
3mbps
4gbps
.1.3.6.1.4.1.9.9.692.1.3.3.1.9
This object indicates the bit rate at which the corresponding
flow monitor processed data for the corresponding traffic flow
during the measurement interval.
CISCO-REPORT-INTERVAL-TC-MIBReportIntervalCount .1.3.6.1.4.1.9.9.692.1.3.3.1.10
This object indicates the packet rate at which the
corresponding flow monitor processed data for the corresponding
traffic flow during the measurement interval.
packets per secondCISCO-REPORT-INTERVAL-TC-MIBReportIntervalCount .1.3.6.1.4.1.9.9.692.1.3.3.1.11
.1.3.6.1.4.1.9.9.692.1.4.1 · 1 row entry · 17 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmConditionTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmConditionTable'
This table lists the standing conditions monitored by the
device.  The table groups descriptions for standing conditions
into condition profiles.
          
The figure below illustrates the relationship between a flow
monitor and a conditions profile.  Observe that a conditions
profile can contain the descriptions for the standing conditions
monitored for more than one flow monitor.  In this case, the
instance of cfmFlowMonitorConditionsProfile for each of these
flow monitors would reference the same conditions profile.
          
+------------------------------------------------+
| flow monitor 1                                 |
|                                                |
| cfmFlowMonitorConditionsProfile.1 = 42 -----+  |
|                                             |  |
| cfmFlowMonitorConditions.1                  |  |
|  N       2 1 0                              |  |
| +-+-...-+-+-+-+                             |  |
| | |     | | | |                             |  |
| +-+-...-+-+-+-+                             |  |
|  ^       ^ ^ ^                              |  |
|  |       | | |                              |  |
+--|-------|-|-|------------------------------|--+
   |       | | |                              |
   |       | | |                              V               
   |       | | |               +-----------------------------+
   |       | | |               | conditions profile 42       |
   |       | | |               | +-------------------------+ |
   |       | | +-----------------| cfmConditionsDescr.42.0 | |
   |       | |                 | +-------------------------+ |
   |       | |                 | +-------------------------+ |
   |       | +-------------------| cfmConditionsDescr.42.1 | |
   |       |                   | +-------------------------+ |
   |       |                   | +-------------------------+ |
   |       +---------------------| cfmConditionsDescr.42.2 | |
   |                           | +-------------------------+ |
   |                           |     :                       |
   |                           |     :                       |
   |                           | +-------------------------+ |
   +-----------------------------| cfmConditionsDescr.42.N | |
                               | +-------------------------+ |
                               +-----------------------------+
          
The figure below illustrates the relationship between a traffic
flow and a conditions profile.  Observe that a conditions
profile can contain the descriptions for the standing conditions
monitored for more than one traffic flow.  In this case, the
instance of cfmFlowMetricsConditionsProfile for each of these
traffic flows would reference the same conditions profile.
          
+------------------------------------------------+
| traffic flow 201                               |
|                                                |
| cfmFlowMetricsConditionsProfile.1.201 = 54 -+  |
|                                             |  |
| cfmFlowMetricsConditions.1.201              |  |
|  N       2 1 0                              |  |
| +-+-...-+-+-+-+                             |  |
| | |     | | | |                             |  |
| +-+-...-+-+-+-+                             |  |
|  ^       ^ ^ ^                              |  |
|  |       | | |                              |  |
+--|-------|-|-|------------------------------|--+
   |       | | |                              |
   |       | | |                              V               
   |       | | |               +-----------------------------+
   |       | | |               | conditions profile 54       |
   |       | | |               | +-------------------------+ |
   |       | | +-----------------| cfmConditionsDescr.54.0 | |
   |       | |                 | +-------------------------+ |
   |       | |                 | +-------------------------+ |
   |       | +-------------------| cfmConditionsDescr.54.1 | |
   |       |                   | +-------------------------+ |
   |       |                   | +-------------------------+ |
   |       +---------------------| cfmConditionsDescr.54.2 | |
   |                           | +-------------------------+ |
   |                           |     :                       |
   |                           |     :                       |
   |                           | +-------------------------+ |
   +-----------------------------| cfmConditionsDescr.54.N | |
                               | +-------------------------+ |
                               +-----------------------------+
          
The figure below illustrates the relationship between the
description of a standing condition and an alarm group if the
standing condition indicates that the device aggregates the
standing condition into an alarm group (i.e., the corresponding
instance of cfmConditionAlarm is 'grouped').
          
+-----------------------------------------+
| conditions profile 42                   |
| +-------------------------------------+ |
| | cfmConditionAlarm.42.9 = 'grouped'  |<-------+
| | cfmConditionAlarmGroup.42.9 = 4 -+  | |      |
| +----------------------------------|--+ |<--+  |
|                                    |    |   |  |
+------------------------------------|----+   |  |
                                     V        |  |
+-----------------------------------------+   |  |
| alarm group 4                           |   |  |
|                                         |   |  |
| cfmAlarmGroupConditionsProfile.4 = 42 ------+  |
| cfmAlarmGroupConditionId.4 = 9 ----------------+
|                                         |
+-----------------------------------------+
cfmConditionEntry row .1.3.6.1.4.1.9.9.692.1.4.1.1
An entry describes a standing condition monitored by the
device. The cfmConditionTable groups descriptions for standing
conditions into condition profiles.

A device creates a row in the cfmConditionTable w…
Column Syntax OID
This object indicates an arbitrary integer-value that uniquely
identifies the condition profile that contains the standing
condition. Observe that the value assigned to a standing
condition does not necessarily persist…
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditionsProfile
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.4.1.1.1
This object indicates an arbitrary integer-value that uniquely
identifies the condition within the scope of the profile. The
value of this column corresponds to the bit position in a binary
string-value representing th…
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditionIdentifier
Type Constraints:
range: 0..2039
.1.3.6.1.4.1.9.9.692.1.4.1.1.2
This object indicates a human-readable description of the
condition.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.4.1.1.3
This object indicates the monitored element used in
determining the state of the standing condition.
SNMPv2-TCAutonomousType
Description:
Represents an independently extensible type identification
value. It may, for example, indicate a particular sub-tree
with further MIB definitions, or define a particular type of
protocol or hardware.
.1.3.6.1.4.1.9.9.692.1.4.1.1.4
This object indicates the type of condition:

'other'
The implementation of the MIB does not recognize the
condition described by this row.

'boolean'
The value monitored only c…
Enumeration
Enumerated Values:
1other
2boolean
3risingThreshold
4fallingThreshold
5risingAndFallingThreshold
.1.3.6.1.4.1.9.9.692.1.4.1.1.5
This object indicates the scaling factor for the corresponding
instance of cfmConditionThreshRise.

This value of this column only has relevance if the
corresponding instance of cfmConditionType is 'rising…
CISCO-FLOW-MONITOR-TC-MIBFlowMetricScale
Type Values:
1yocto
2zepto
3atto
4femto
5pico
6nano
7micro
8milli
9units
10kilo
11mega
12giga
13tera
14exa
15peta
16zetta
17yotta
.1.3.6.1.4.1.9.9.692.1.4.1.1.6
This object indicates the precision for the corresponding
instance of cfmConditionThreshRise.

This value of this column only has relevance if the
corresponding instance of cfmConditionType is 'risingThres…
CISCO-FLOW-MONITOR-TC-MIBFlowMetricPrecision
Type Constraints:
range: -8..-1
range: 1..9
.1.3.6.1.4.1.9.9.692.1.4.1.1.7
This object indicates the value of the rising threshold.

This value of this column only has relevance if the
corresponding instance of cfmConditionType is 'risingThreshold'
or 'risingAndFallingThreshold'.
CISCO-FLOW-MONITOR-TC-MIBFlowMetricValue
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.692.1.4.1.1.8
This object indicates the scaling factor for the corresponding
instance of cfmConditionThreshFall.

The value of this column only has relevance if the
corresponding instance of cfmConditionType is 'falling…
CISCO-FLOW-MONITOR-TC-MIBFlowMetricScale
Type Values:
1yocto
2zepto
3atto
4femto
5pico
6nano
7micro
8milli
9units
10kilo
11mega
12giga
13tera
14exa
15peta
16zetta
17yotta
.1.3.6.1.4.1.9.9.692.1.4.1.1.9
This object indicates the precision for the corresponding
instance of cfmConditionThreshFall.

The value of this column only has relevance if the
corresponding instance of cfmConditionType is 'fallingThres…
CISCO-FLOW-MONITOR-TC-MIBFlowMetricPrecision
Type Constraints:
range: -8..-1
range: 1..9
.1.3.6.1.4.1.9.9.692.1.4.1.1.10
This object indicates the value of the falling threshold.

The value of this column only has relevance if the
corresponding instance of cfmConditionType is 'fallingThreshold'
or 'risingAndFallingThreshold'.
CISCO-FLOW-MONITOR-TC-MIBFlowMetricValue
Type Constraints:
range: -1000000000..1000000000
.1.3.6.1.4.1.9.9.692.1.4.1.1.11
This object indicates how the device samples the monitored
value before determining whether to assert the condition:

'other'
The implementation of the MIB does not recognize the
how th…
Enumeration
Enumerated Values:
1other
2raw
3slidingWindowAvg
4expDecayingAvg
.1.3.6.1.4.1.9.9.692.1.4.1.1.13
This object indicates the sample window used by the device to
compute an exponentially decaying average in the case that the
corresponding instance of cfmConditionSampleType is 'averaged'.

The value of th…
Unsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.9.9.692.1.4.1.1.14
This object indicates whether the device treats the standing
condition as an alarm condition:

'none'
The device does not treat the standing condition as an
alarm condition.
Enumeration
Enumerated Values:
1none
2discrete
3grouped
.1.3.6.1.4.1.9.9.692.1.4.1.1.15
This object indicates the actions taken by the device when the
alarm condition changes state:

'syslog'
The device sends a syslog message.

'snmp'
The device sends a c…
Bits
Enumerated Values:
0syslog
1snmp
.1.3.6.1.4.1.9.9.692.1.4.1.1.16
This object indicates the severity of the alarm condition.

The value of this column only have relevance if the
corresponding instance of cfmConditionAlarm is 'discrete'.
CISCO-TCCiscoAlarmSeverity
Type Values:
1cleared
2indeterminate
3critical
4major
5minor
6warning
7info
.1.3.6.1.4.1.9.9.692.1.4.1.1.17
This object indicates the alarm group the device aggregates the
standing condition into.

The value of this column only has relevance if the corresponding
instance of cfmConditionAlarm is 'grouped'.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorAlarmGroupIdentifier
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.4.1.1.18
.1.3.6.1.4.1.9.9.692.1.5.1 · 1 row entry · 10 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmAlarmGroupTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmAlarmGroupTable'
This table lists alarm groups maintained by the device.
cfmAlarmGroupEntry row .1.3.6.1.4.1.9.9.692.1.5.1.1
An entry describes an alarm group. An alarm group defines an
alarm condition that is raised when a configured number of flows
in a set of flows asserts a configured standing condition.

The figure below ill…
Indexes
Column Syntax OID
This object indicates an arbitrary integer-value that uniquely
identifies the alarm group. Observe that the value assigned to
an alarm group does not necessarily persist across restarts.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorAlarmGroupIdentifier
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.5.1.1.1
This object indicates a human-readable description of the
alarm group.
SNMP-FRAMEWORK-MIBSnmpAdminString
Type Constraints:
range: 0..255
.1.3.6.1.4.1.9.9.692.1.5.1.1.2
This object indicates the conditions profile that contains
the description of the standing profile aggregated by the
alarm group.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditionsProfile
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.5.1.1.3
This object indicates the standing condition aggregated by the
alarm group.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditionIdentifier
Type Constraints:
range: 0..2039
.1.3.6.1.4.1.9.9.692.1.5.1.1.4
This object indicates the set of traffic flows aggregated by
the alarm group.
CISCO-FLOW-MONITOR-TC-MIBFlowSetIdentifier
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.5.1.1.5
This object indicates the number of traffic flows in the set of
traffic flows indicated by the corresponding instance of
cfmAlarmGroupFlowSet.
traffic flowsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.5.1.1.6
This object indicates the units for the corresponding instance
of cfmAlarmGroupThreshold:

'other'
The MIB implementation does not recognize the units in
which the value of the correspo…
Enumeration
Enumerated Values:
1other
2flows
3percent
.1.3.6.1.4.1.9.9.692.1.5.1.1.7
This object indicates a number of flows that must assert the
standing condition indicated by the corresponding instance of
cfmAlarmGroupCondition before raising an alarm.

If the corresponding instance of …
Unsigned32
Constraints:
range: 0-4294967295
.1.3.6.1.4.1.9.9.692.1.5.1.1.8
This object indicates whether the alarm group has raised an
alarm.
SNMPv2-TCTruthValue
Type Values:
1true
2false
Description:
Represents a boolean value.
.1.3.6.1.4.1.9.9.692.1.5.1.1.9
This object indicates the number of traffic flows currently
asserting the standing condition aggregated by the alarm group.
traffic flowsSNMPv2-SMIGauge32
Type Constraints:
range: 0..4294967295
.1.3.6.1.4.1.9.9.692.1.5.1.1.10
.1.3.6.1.4.1.9.9.692.1.5.3 · 1 row entry · 3 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmAlarmGroupFlowTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmAlarmGroupFlowTable'
This table lists the traffic flows contained by each set of
flows configured for the alarm groups contained by the
cfmAlarmGroupTable.
cfmAlarmGroupFlowEntry row .1.3.6.1.4.1.9.9.692.1.5.3.1
An entry describes a traffic flow contained by a set of flows.

An alarm group aggregates a standing condition from a set of
flows. cfmAlarmFlowSetId uniquely identifies a set of traffic
flows.
Column Syntax OID
This object indicates an arbitrary integer-value that uniquely
identifies the set of traffic flows that contains the traffic
flow represented by the row. Observe that the value assigned
to
a flow set does not necessari…
CISCO-FLOW-MONITOR-TC-MIBFlowSetIdentifier
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.5.3.1.1
This object identifies the flow monitor responsible for the
traffic flow.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorIdentifier
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.5.3.1.2
This object identifies the traffic flow.
CISCO-FLOW-MONITOR-TC-MIBFlowIdentifier
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.5.3.1.3
.1.3.6.1.4.1.9.9.692.1.6.3 · 1 row entry · 7 columns
Uses the cisco variant from /opt/observium/mibs/cisco.
Command help
Walk cfmAlarmHistoryTable
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CISCO-FLOW-MONITOR-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CISCO-FLOW-MONITOR-MIB::cfmAlarmHistoryTable'
This table lists a history of the changes in the state of alarm
conditions monitored by the device.
cfmAlarmHistoryEntry row .1.3.6.1.4.1.9.9.692.1.6.3.1
An entry describes the change in the state of an alarm
condition observed by the device.

The device creates a row in the cfmAlarmHistoryTable when it
observes a change in the state of an alarm condition.
Column Syntax OID
This object indicates an arbitrary integer-value that uniquely
identifies the event. Observe that the value assigned to a
alarm history entry does not necessarily persist across
restarts.
Unsigned32
Constraints:
range: 1-4294967295
.1.3.6.1.4.1.9.9.692.1.6.3.1.1
This object indicates the type of event:

'cleared'
The event signaled an alarm condition transitioning to
the cleared state.

'raised'
The event signalled an alarm condition tran…
Enumeration
Enumerated Values:
1cleared
2raised
.1.3.6.1.4.1.9.9.692.1.6.3.1.2
This object indicates the entity that caused the event.

If the alarm condition has an association with a flow monitor,
then the value of this column is a row in the
cfmFlowMonitorTable.

If …
SNMPv2-TCRowPointer
Description:
Represents a pointer to a conceptual row. The value is the
name of the instance of the first accessible columnar object
in the conceptual row.

For example, ifIndex.3 would point to the 3rd row in the
ifTable…
.1.3.6.1.4.1.9.9.692.1.6.3.1.3
This object indicates the conditions profile containing the
description of the alarm condition that changed state.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditionsProfile
Type Constraints:
range: 1..4294967295
.1.3.6.1.4.1.9.9.692.1.6.3.1.4
This object indicates the alarm condition that changed state.
CISCO-FLOW-MONITOR-TC-MIBFlowMonitorConditionIdentifier
Type Constraints:
range: 0..2039
.1.3.6.1.4.1.9.9.692.1.6.3.1.5
This object indicates the severity of the alarm condition that
changed state.
CISCO-TCCiscoAlarmSeverity
Type Values:
1cleared
2indeterminate
3critical
4major
5minor
6warning
7info
.1.3.6.1.4.1.9.9.692.1.6.3.1.6
This object indicates the value of sysUpTime when the alarm
condition changed state.

In the case the device updates standing/alarm conditions at the
same time it captures a measurement interval, the value…
SNMPv2-TCTimeStamp
Based On: SNMPv2-SMITimeTicks
Description:
The value of the sysUpTime object at which a specific
occurrence happened. The specific occurrence must be

defined in the description of any object defined using this
type.

If sysUpTime is reset t…
.1.3.6.1.4.1.9.9.692.1.6.3.1.7