cienaCesPortXcvrVoltageLowNotification

CIENA-CES-PORT-XCVR-MIB · .1.3.6.1.4.1.1271.2.2.9.0.10

Object

notification
A cienaCesPortXcvrVoltageLowNotification is sent if the transceiver voltage falls below the 
threshold. To enable the device to send this notification: cienaCesPortXcvrVoltageChangeTrapState,
cienaCesLogicalPortConfigPortAllTrapState, and cienaCesPortAllTrapState need to be set to enabled.
These objects are set to enabled by default. Variable bindings include: cienaGlobalSeverity,
cienaGlobalMacAddress, cienaCesPortXcvrNotifChassisIndex, cienaCesPortXcvrNotifShelfIndex,
cienaCesPortXcvrNotifSlotIndex, and cienaCesPortXcvrNotifPortNumber.

Context

MIB
CIENA-CES-PORT-XCVR-MIB
OID
.1.3.6.1.4.1.1271.2.2.9.0.10
Type
notification
Status
current
Parent
cienaCesPortXcvrMIBNotifications

Notifications are emitted by an agent; they cannot be read with snmpget or walked.

Inspect the notification definition
/usr/bin/snmptranslate -Pud -Ir -Td -m 'CIENA-CES-PORT-XCVR-MIB' -M '/opt/observium/mibs/ciena:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CIENA-CES-PORT-XCVR-MIB::cienaCesPortXcvrVoltageLowNotification'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CIENA-CES-PORT-XCVR-MIB' -M '/opt/observium/mibs/ciena:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CIENA-CES-PORT-XCVR-MIB::cienaCesPortXcvrVoltageLowNotification'

Syntax

No syntax metadata recorded.

Values & Constraints

No enumerated values or constraints recorded.