cienaCesOamErrFrameWindow

CIENA-CES-OAM-MIB · .1.3.6.1.4.1.1271.2.3.5.1.1.8.1.5

Object

column tenths of a second Unsigned32
The amount of time (in 100ms increments) over which the
threshold is defined.  The default value is 10 (1 second).
                                     
If cienaCesOamErrFrameThreshold frame errors occur within a window
of cienaCesOamErrFrameWindow seconds (measured in tenths of
seconds), an Event Notification OAMPDU should be generated with
an Errored Frame Event TLV indicating the threshold has been
crossed in this window.

Context

MIB
CIENA-CES-OAM-MIB
OID
.1.3.6.1.4.1.1271.2.3.5.1.1.8.1.5
Type
column
Access
readonly
Status
current
Units
tenths of a second
Parent
cienaCesOamEventConfigEntry
Table
cienaCesOamEventConfigTable
Siblings
11

Syntax

tenths of a second Unsigned32

Values & Constraints

Object Constraints
range: 10-600

Related Objects

Sibling Objects