cienaCesOamErrFrameSecsSummaryWindow

CIENA-CES-OAM-MIB · .1.3.6.1.4.1.1271.2.3.5.1.1.8.1.8

Object

column tenths of a second Integer32
The amount of time (in 100ms intervals) over which the
threshold is defined.  The default value is 100 (10 seconds).
                              
If cienaCesOamErrFrameSecsSummaryThreshold frame errors occur
within a window of cienaCesOamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window.

Context

MIB
CIENA-CES-OAM-MIB
OID
.1.3.6.1.4.1.1271.2.3.5.1.1.8.1.8
Type
column
Access
readonly
Status
current
Units
tenths of a second
Parent
cienaCesOamEventConfigEntry
Table
cienaCesOamEventConfigTable
Siblings
11

Syntax

tenths of a second Integer32

Values & Constraints

Object Constraints
range: 100-9000

Related Objects

Sibling Objects