cienaCesOamErrFrameSecsSummaryThreshold

CIENA-CES-OAM-MIB · .1.3.6.1.4.1.1271.2.3.5.1.1.8.1.9

Object

column errored frame seconds Integer32
The number of errored frame seconds that must occur for this
event to be triggered.  The default value is one errored frame
second.
                              
If cienaCesOamErrFrameSecsSummaryThreshold frame errors occur
within a window of cienaCesOamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window.

Context

MIB
CIENA-CES-OAM-MIB
OID
.1.3.6.1.4.1.1271.2.3.5.1.1.8.1.9
Type
column
Access
readonly
Status
current
Units
errored frame seconds
Parent
cienaCesOamEventConfigEntry
Table
cienaCesOamEventConfigTable
Siblings
11

Syntax

errored frame seconds Integer32

Values & Constraints

Object Constraints
range: 0-65535

Related Objects

Sibling Objects