cienaCesOamErrFrameSecsSummaryThreshold
CIENA-CES-OAM-MIB ·
.1.3.6.1.4.1.1271.2.3.5.1.1.8.1.9
Object
column errored frame secondsInteger32
The number of errored frame seconds that must occur for this
event to be triggered. The default value is one errored frame
second.
If cienaCesOamErrFrameSecsSummaryThreshold frame errors occur
within a window of cienaCesOamErrFrameSecsSummaryWindow (in tenths
of seconds), an Event Notification OAMPDU should be generated
with an Errored Frame Seconds Summary Event TLV indicating the
threshold has been crossed in this window.
Context
- MIB
- CIENA-CES-OAM-MIB
- OID
.1.3.6.1.4.1.1271.2.3.5.1.1.8.1.9- Type
- column
- Access
- readonly
- Status
- current
- Units
- errored frame seconds
- Parent
- cienaCesOamEventConfigEntry
Net-SNMP examples
How SNMP and these commands workWalk the column to discover its indexed instances, or supply every index to read one instance.
Walk the column
/usr/bin/snmpbulkwalk -v2c -c '<community>' -Pud -Ir -OQUs -m 'CIENA-CES-OAM-MIB' -M '/opt/observium/mibs/ciena:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIENA-CES-OAM-MIB::cienaCesOamErrFrameSecsSummaryThreshold'
More examples
Read one indexed instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CIENA-CES-OAM-MIB' -M '/opt/observium/mibs/ciena:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CIENA-CES-OAM-MIB::cienaCesOamErrFrameSecsSummaryThreshold.<cienaCesOamEventPort>'
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CIENA-CES-OAM-MIB' -M '/opt/observium/mibs/ciena:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CIENA-CES-OAM-MIB::cienaCesOamErrFrameSecsSummaryThreshold'
Syntax
errored frame secondsInteger32
Values & Constraints
Object Constraints
range: 0-65535