gnGenStatDeviceODUStatus
CERAGON-MIB ·
.1.3.6.1.4.1.2281.2.1.9.1.10
Object
column
mandatory
OctetString
ODU status reported with this parameter. Bit1 is MSB. The bit is set when a fault occurs. The bit is cleared when the fault clears. bit 1 = Power Supply status bit 2 = Synthesizer lock status bit 3 = Tx level status bit 4 = ATPC status bit 5 = Rx level status bit 6 = Not currently used. bit 7 = Temperature status bit 8 = Not currently used. bit 9 = ODU loopback status. bit 10 = Internal use (by application). bit 11 = Tx is in Mute.
Context
- MIB
- CERAGON-MIB
- OID
.1.3.6.1.4.1.2281.2.1.9.1.10- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- gnGenStatDeviceEntry
Syntax
OctetString
Values & Constraints
Object Constraints
range: 2-2