cat2600TsSamplingPeriod

CAT2600-MIB · .1.3.6.1.4.1.9.1.111.1.2.1.1.26

Object

scalar mandatory r/w Integer32
Sampling period in minutes for determining if the
error rate of CRC errors has been exceeded.
The default value for this object is 10 minutes. The
valid range is 1-120.

Context

MIB
CAT2600-MIB
OID
.1.3.6.1.4.1.9.1.111.1.2.1.1.26
Type
scalar
Access
readwrite
Status
mandatory
Parent
cat2600TsConfig

Scalars have one instance, identified by the .0 suffix.

Read the scalar instance
/usr/bin/snmpget -v2c -c '<community>' -Pud -Ir -OQUv -m 'CAT2600-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'udp:<hostname>:161' 'CAT2600-MIB::cat2600TsSamplingPeriod.0'
More examples
Translate to a numeric OID
/usr/bin/snmptranslate -Pud -Ir -On -m 'CAT2600-MIB' -M '/opt/observium/mibs/cisco:/opt/observium/mibs/rfc:/opt/observium/mibs/net-snmp' 'CAT2600-MIB::cat2600TsSamplingPeriod'

Syntax

Integer32

Values & Constraints

Object Constraints
range: 1-120